• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

VDE 0473-811-1-2 : 2001

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
Superseded date

01-12-2012

Published date

12-01-2013

1 Anwendungsbereich
2 Prüfbedingungen und -anforderungen
3 Anwendbarkeit
4 Typprüfungen und andere Prüfungen
5 Vorkonditionierung
6 Prüftemperatur
7 Median
8 Thermische Alterung
  8.1 Alterung im Wärmeschrank
  8.2 Alterung in der Druckkammer unter Luft
  8.3 Alterung in der Druckkammer unter Sauerstoff
  8.4 Verfahren zur Messung des Luftdurchsatzes von
      Wärmeschränken
Anhang ZA (normativ) Normative Verweisungen auf
          internationale Publikationen mit ihren
          entsprechenden europäischen Publikationen

Diese Norm enthält Prüfverfahren für die Prüfung polymerer Isolier- und Mantelwerkstoffe von Kabeln und isolierten Leitungen zur Energieverteilung und Nachrichtenübertragung einschliesslich Schiffskabeln und in Offshore-Anwendungen. Dieser Hauptabschnitt 2 des Teils 1 beschreibt die thermische Alterung der gebräuchlichsten Typen von Isolier- und Mantelwerkstoffen (Elastomere, PVC, PE, PP usw.).

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
EN 60811-1-2:1995/A2:2000 Identical
IEC 60811-1-2:1985 Identical
DIN EN 60811-1-2 : 2001 Identical
DIN EN 60811-1-2 : 2001 Corresponds

DIN VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
VDE 0262 : 95 COR 1 2004 XLPE INSULATED AND PVC SHEATHED INSTALLATION CABLES WITH NOMINAL VOLTAGE 0,6/1 KV
DIN VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF NOMINAL VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
VDE 0281-12 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES SOUPLES RESISTANT A LA CHALEUR
VDE 0304-22 : 2006 Electrical insulating materials - Thermal endurance properties Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria (IEC 60216-2:2005); German version EN 60216-2:2005
VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
VDE 0266 : 2000 COR 1 2006 POWER CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE - NOMINAL VOLTAGES Uo/U 0,6/1 KV
VDE 0250-204 : 2000
VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C
DIN VDE 0262 : 95 COR 1 2004 XLPE INSULATED AND PVC SHEATHED INSTALLATION-CABLES WITH NOMINAL VOLTAGE 0,6/1 KV
DIN VDE 0250-204 : 2000 CABLES, WIRES AND CORDS FOR POWER INSTALLATION - PVC-INSTALLATION CABLE NYM
DIN VDE 0266 : 2000 COR 1 2006 POWER CABLES WITH IMPROVED CHARACTERISTICS IN THE CASE OF FIRE - NOMINAL VOLTAGES U(INDEX)0/U 0,6/1 KV
DIN VDE 0888-5 : 1999 OPTICAL FIBRE CABLES FOR COMMUNICATION SYSTEMS - PART 5: OUTDOOR FAN OUT CABLES
DIN VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE
DIN VDE 0888-4 : 1999 OPTICAL FIBRE CABLES FOR COMMUNICATION SYSTEMS - PART 4: INDOOR CABLES WITH ONE FIBRE

DIN EN 60811-1-4 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
IEC 60538:1976 Electric cables, wires and cords: Methods of test for polyethylene insulation and sheath
VDE 0473-811-1-4 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION; SECTION 4: TEST AT LOW TEMPERATURE
EN 60811-3-2 : 95 AMD 2 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST
DIN EN 60811-1-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-1: GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TEST FOR DETERMINING THE MECHANICAL PROPERTIES
HD 505.1.1 : 200S3 COMMON TEST METHODS FOR INSULATING & SHEATHING MATERIALS OF ELECTRIC CABLES: METHODS FOR GENERAL APPLICATION: MEASUREMENT OF THICKNESS OVERALL DIMENSIONS TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
VDE 0473-811-1-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-1: GENERAL APPLICATION; MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS; TEST FOR DETERMINING THE MECHANICAL PROPERTIES
VDE 0473-811-3-2 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST, THERMAL STABILITY TEST
IEC 60538A:1980 First supplement
DIN EN 60811-3-2 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
IEC 60811-3-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 3: Methods specific to PVC compounds - Section Two: Loss of mass test - Thermal stability test

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.