• There are no items in your cart

08/30153135 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

BS ISO 28218 - RADIATION PROTECTION - PERFORMANCE CRITERIA FOR RADIOBIOASSAY

Available format(s)

Hardcopy , PDF

Superseded date

10-31-2010

Language(s)

English

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
  4.1 Symbols
  4.2 Abbreviated terms
5 Performance Measures
  5.1 Decision threshold (y[*]) and Detection Limit (y[#])
      5.1.1 Preamble
      5.1.2 General procedure for the determination of the
            characteristic limits
  5.2 Relative bias and bias performance criteria
  5.3 Repeatability performance criteria
6 Performance criteria for in vivo radiobioassay
  6.1 General
  6.2 Service laboratory criteria
      6.2.1 General
      6.2.2 Equipment
      6.2.3 Services
      6.2.4 Location
  6.3 Identification of radionuclides
  6.4 Quantification
  6.5 Reporting results
  6.6 Records retention
7 Performance criteria for in vitro radiobioassay
  7.1 General
  7.2 Responsibilities of the customer that could impact
      the service laboratory's performance
  7.3 Analytical methodology
      7.3.1 General
      7.3.2 Analytical equipment and facilities
      7.3.3 Operating procedures and instructions
  7.4 Reporting results
  7.5 Records retention
8 Quality assurance and quality control for radiobioassay
  laboratories
  8.1 General
  8.2 Quality assurance
  8.3 Quality assurance plan
      8.3.1 Points of the plan
      8.3.2 Responsible quality assurance person or organization
  8.4 Quality control
      8.4.1 General
      8.4.2 Quality control procedures
      8.4.3 Performance checks of instrumentation for in vivo and
            in vitro radiobioassay
      8.4.4 Performance checks on in vitro (biological samples)
            radiobioassay procedures
      8.4.5 Performance criteria checks for in vivo and in vitro
            radiobioassay
      8.4.6 Use of reference radioactive materials for equipment
            calibrations
9 Performance testing programme
  9.1 General
  9.2 In vivo radiobioassay
      9.2.1 General
      9.2.2 Testing protocols
      9.2.3 Test categories
      9.2.4 Test radionuclides and activity ranges
      9.2.5 Test phantom for lung measurement
      9.2.6 Test phantom for total body measurements
      9.2.7 Test phantoms for thyroid and for other types of
            in vivo measurement
  9.3 In vitro radiobioassay
      9.3.1 General
      9.3.2 Testing protocol
      9.3.3 Test radionuclides and activity ranges
Annex A (informative) Detection Limit - Models for applications
      A.1 Model in ionizing-radiation measurements
      A.2 Model for general chemical analytics
      A.3 General expressions of practical use
Annex B (informative) Detection Limit - Application examples
      B.1 Example 1: Direct measurement of an internal
          contamination with WBC (linear background)
          B.1.1 The model
          B.1.2 The associations
          B.1.3 Standard uncertainty
          B.1.4 Decision threshold y[*]
          B.1.5 Detection Limit y[#]
      B.2 Example 2: Determination of plutonium by alpha
          spectrometry
          B.2.1 The model
          B.2.2 The associations
          B.2.3 Standard uncertainty
          B.2.4 Decision threshold y[*]
          B.2.5 Detection Limit y[#]
      B.3 Example 3: Determination of uranium in urine by ICP-MS
          B.3.1 The model
          B.3.2 The associations
          B.3.3 Standard uncertainty
          B.3.4 Decision threshold y[*]
          B.3.5 Detection Limit y[#]
      B.4 Example 4: Tritium measurement in urine samples with LSC
          B.4.1 The model
          B.4.2 The associations
          B.4.3 Standard uncertainty
          B.4.4 Decision threshold y[*]
          B.4.5 Detection Limit y[#]
Bibliography

Committee
NCE/2
DocumentType
Draft
Pages
54
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
ISO 5725-3:1994 Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method
ANSI N13.30 : 2011(R2017) PERFORMANCE CRITERIA FOR RADIOBIOASSAY
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ASTM C 1068 : 2015 : REDLINE Standard Guide for Qualification of Measurement Methods by a Laboratory Within the Nuclear Industry

View more information
US$23.96
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.