AAMI ISO 10993-1:2009

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS
Withdrawn date

03-12-2019

Published date

01-01-2013

Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of ISO 10993-1:2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General principles applying to biological evaluation
  of medical devices
5 Categorization of medical devices
6 Biological evaluation process
7 Interpretation of biological evaluation data and overall
  biological safety assessment
Annex A (informative) - Biological evaluation tests
Annex B (informative) - Guidance on the risk management process
Annex C (informative) - Suggested procedure for literature review
Bibliography

Specifies: - the general principles governing the biological evaluation of medical devices within a risk management process; - the general categorization of devices based on the nature and duration of their contact with the body; - the evaluation of existing relevant data from all sources; - the identification of gaps in the available data set on the basis of a risk analysis; - the identification of additional data sets necessary to analyze the biological safety of the medical device; - the assessment of the biological safety of the medical device.

Committee
WG 01
DocumentType
Standard
ProductNote
Reconfirmed 2009
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Withdrawn
SupersededBy

Standards Relationship
ISO 10993-1:2009 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 10993-3:2014 Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity
ISO 10993-4:2017 Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood
ISO 10993-16:2017 Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables
ISO/TS 10993-20:2006 Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices
ISO 10993-13:2010 Biological evaluation of medical devices Part 13: Identification and quantification of degradation products from polymeric medical devices
ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
ISO 10993-2:2006 Biological evaluation of medical devices — Part 2: Animal welfare requirements
ISO 7405:2008 Dentistry Evaluation of biocompatibility of medical devices used in dentistry
ISO 10993-14:2001 Biological evaluation of medical devices Part 14: Identification and quantification of degradation products from ceramics
ISO 10993-18:2005 Biological evaluation of medical devices Part 18: Chemical characterization of materials
ISO/TS 10993-19:2006 Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials
ISO 10993-10:2010 Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization
ISO 9004:2009 Managing for the sustained success of an organization A quality management approach
ISO 10993-11:2017 Biological evaluation of medical devices — Part 11: Tests for systemic toxicity
ISO 10993-12:2012 Biological evaluation of medical devices Part 12: Sample preparation and reference materials
ISO 10993-7:2008 Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals
ISO 10993-17:2002 Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances
ISO 9001:2015 Quality management systems — Requirements
ISO 10993-9:2009 Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products
ISO 9000:2015 Quality management systems — Fundamentals and vocabulary
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 10993-6:2016 Biological evaluation of medical devices Part 6: Tests for local effects after implantation

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.