• There are no items in your cart

API 540:1999

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS
Available format(s)

Hardcopy , PDF

Superseded date

02-22-2021

Language(s)

English

Published date

01-01-2006

1 INTRODUCTION
   1.1 Purpose
   1.2 Scope
   1.3 References
2 CLASSIFIED LOCATIONS OR ELECTRICAL EQUIPMENT
   2.1 Purpose
   2.2 Scope
   2.3 Classification of Flammable and Combustible
         Liquids and Gases
   2.4 Classification of Locations
   2.5 Electrical Equipment for Classified Locations
   2.6 Alternative Design in Classified Locations
3 ELECTRICAL ENERGY EFFICIENCY
   3.1 Purpose
   3.2 Scope
   3.3 The Role of Electrical Efficiency
   3.4 Definition of Efficiency
   3.5 Specification Considerations
   3.6 Economic Evaluation
   3.7 Cogeneration and Energy Recovery
   3.8 Design Considerations
   3.9 Relationship to Power Factor
   3.10 Definitions and Conversion Factors
4 FACILITY POWER SYSTEMS
   4.1 Purpose
   4.2 Scope
   4.3 Power Sources
   4.4 System Voltages
   4.5 Power System Arrangements
   4.6 Power System Studies
   4.7 System Protection
   4.8 Fuses
   4.9 Circuit Breakers
   4.10 Switchgear
   4.11 Transformers
   4.12 Overhead Electric Power Distribution
5 Grounding and Lightning Protection
   5.1 Purpose
   5.2 Scope
   5.3 Static Electricity and Stray Currents
   5.4 System Grounding
   5.5 Equipment Grounding
   5.6 Connections to Earth
   5.7 Lightning Protection
6 MOTORS AND CONTROLLERS
   6.1 Purpose
   6.2 Scope
   6.3 Motor Rating and Efficiency
   6.4 Relative Locations of Motors and Controllers
   6.5 Frequencies
   6.6 Standard Voltage for Motors
   6.7 Motor Voltage Selection
   6.8 Temperature and Altitude Considerations in
         Motor Applications
   6.9 Other Conditions Affecting Design and
         Application
   6.10 Types of Motor Construction
   6.11 Installation
   6.12 Construction of Totally Enclosed Motors
   6.13 Motors for Class I Locations
   6.14 Motors for Class II Locations
   6.15 Motor Service Factor
   6.16 Frequency of Starting
   6.17 Temperature, Vibration and Current Indicators
   6.18 Conduit or Terminal Box
   6.19 Space Heaters
   6.20 Bearings and Lubrication
   6.21 Torque Requirements
   6.22 Method of Starting
   6.23 Motor Controllers
   6.24 Application of Motor Control
   6.25 Means of Disconnection
   6.26 Coordination of Controller Applications With
         Fuses or Circuit Breakers on Low-Voltage
         Systems
   6.27 Overload Protection: Special Applications
   6.28 Voltage Limitations
   6.29 Application of Outdoor and Indoor Types
   6.30 Pushbutton Stations
   6.31 Additional References
7 LIGHTING
   7.1 Purpose
   7.2 Scope
   7.3 Definition of Terms
   7.4 Lighting Facilities
   7.5 Luminaires
   7.6 Light Quality
   7.7 Illuminance
   7.8 Installation Initial Values
   7.9 Lighting System Power Supply
   7.10 Emergency Lighting
   7.11 Design Considerations
   7.12 Estimating Electric Power Requirements
   7.13 Illuminance Meters
8 WIRING
   8.1 Purpose
   8.2 Scope
   8.3 General
   8.4 Conduit Systems
   8.5 Electrical Metallic Tubing
   8.6 Busways
   8.7 Wireways
   8.8 Cable Trays
   8.9 Manholes and Above Grade Pull Points
   8.10 Wire and Cable
   8.11 Fireproofing
9 POWER SYSTEMS FOR INSTRUMENTATION AND PROCESS
   CONTROL
   9.1 Purpose
   9.2 Scope
   9.3 Basic Design Criteria
   9.4 Design Considerations
   9.5 Electric Power Systems
   9.6 Distribution System
   9.7 Wiring Methods
   9.8 System and Equipment Grounding
   9.9 Considerations for Classified Locations
10 SPECIAL EQUIPMENT
   10.1 Purpose
   10.2 Scope
   10.3 General
   10.4 Communication Systems
   10.5 Supervisory Control and Data Acquisition
         Equipment (SCADA)
   10.6 Closed-Circuit Television (CCTV)
   10.7 Obstruction and Warning Lighting
   10.8 Navigation Lighting
   10.9 Fire Alarm Systems
   10.10 Electric Heat Tracing
   10.11 Cathodic Protection Systems
   10.12 Desalters and Precipitators
   10.13 Portable Equipment
11 INHERENT ELECTRICAL SAFETY
   11.1 General
   11.2 References
   11.3 Specifics
APPENDIX A - (INFORMATIVE) INHERENT SAFETY
             CONSIDERATIONS

Provides information on electrical installations in petroleum facilities.

DocumentType
Standard
Pages
112
ProductNote
Reconfirmed 1999
PublisherName
American Petroleum Institute
Status
Superseded
SupersededBy

ISA RP12.1 : 1960 ELECTRICAL INSTRUMENTS IN HAZARDOUS ATMOSPHERES
ISA 12.16.01 : 2002 ELECTRICAL APPARATUS FOR USE IN CLASS 1, ZONE 1 HAZARDOUS (CLASSIFIED) LOCATIONS: TYPE OF PROTECTION - INCREASED SAFETY
IEEE 519-2014 REDLINE IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems
NFPA 91 : 2015 EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS
API 500 : 2012 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2
IEEE 32-1972 IEEE Standard Requirements, Terminology, and Test Procedures for Neutral Grounding Devices
NEMA MG 1 : 2016 MOTORS AND GENERATORS
NEMA MG 2:2014 Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators
IEEE C57.12.01-2015 REDLINE IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers
NFPA 780 : 2017 INSTALLATION OF LIGHTNING PROTECTION SYSTEMS
NFPA 110 : 2016 EMERGENCY AND STANDBY POWER SYSTEMS
CFR 29(PTS1900-1910) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
ANSI C80.5 : 2015 ELECTRICAL RIGID METAL CONDUIT - ALUMINUM (ERMC-A)
API 546 : 2008 BRUSHLESS SYNCHRONOUS MACHINES - 500 KVA AND LARGER
IEEE 841-2009 IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp)
API 614 : 2008 LUBRICATION, SHAFT-SEALING AND OIL-CONTROL SYSTEMS AND AUXILIARIES
ISA RP12.24.01 : 1998 RECOMMENDED PRACTICE FOR CLASSIFICATIONS OF LOCATIONS FOR ELECTRICAL INSTALLATIONS CLASSIFIED AS CLASS I ZONE 0, ZONE 1, OR ZONE 2
NEMA ICS 6-1993 (R2006) Industrial Control and Systems: Enclosures
NFPA 90A : 2018 INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS
NFPA 69 : 2014 EXPLOSION PREVENTION SYSTEMS
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
API 2003 : 2015 PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, LIGHTNING, AND STRAY CURRENTS
IEEE 493 : 2007 DESIGN OF RELIABLE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
NACE RP 01 76 : 2003 CORROSION CONTROL OF STEEL FIXED OFFSHORE STRUCTURES ASSOCIATED WITH PETROLEUM PRODUCTION
WC 5-1992 THERMOPLASTIC-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
NFPA 496 : 2017 PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT
IEEE C57.96-2013 IEEE Guide for Loading Dry-Type Distribution and Power Transformers
API 651 : 2014 CATHODIC PROTECTION OF ABOVEGROUND PETROLEUM STORAGE TANKS
WC 8:1988 ETHYLENE-PROPYLENE-RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
RR-F-191-4 Revision F:2008 FENCING, WIRE AND POST, METAL (CHAIN-LINK FENCE ACCESSORIES)
NACE RP 06 75 : 1988 CORROSION CONTROL OF OFFSHORE STEEL PIPELINES
API 552 : 1994 TRANSMISSION SYSTEMS
IEEE 242 : 2001 PROTECTION AND COORDINATION OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
AGMA 6019 : E GEARMOTORS USING SPUR, HELICAL, HERRINGBONE, STRAIGHT BEVEL OR SPIRAL BEVEL GEARS
IEEE 80-2013 IEEE Guide for Safety in AC Substation Grounding
ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
ANSI C80.1 : 2015 ELECTRICAL RIGID STEEL CONDUIT (ERSC)
IEEE C2-2017 NATIONAL ELECTRICAL SAFETY CODE (NESC)(R)
IEEE C57.92-1981 IEEE Guide for Loading Mineral-Oil-Immersed Power Transformers Up to and Including 100 MVA with 55 C or 65 C Average Winding Rise
NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
API 505 : 1997 RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS I, ZONE 0, ZONE 1, AND ZONE 2
IEEE C57.111 : 1989 GUIDE FOR ACCEPTANCE OF SILICONE INSULATING FLUID AND ITS MAINTENANCE IN TRANSFORMERS
IEEE 142 : 2007 GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
WC 3-1992 RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
IEEE 1100 : 2005 POWERING AND GROUNDING ELECTRONIC EQUIPMENT
NFPA 499 : 2017 CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS
API 2001 : 2012 FIRE PROTECTION IN REFINERIES
API 610 : 2010 CENTRIFUGAL PUMPS FOR PETROLEUM, PETROCHEMICAL AND NATURAL GAS INDUSTRIES
NEMA ICS 1 : 2000(R2015) INDUSTRIAL CONTROL AND SYSTEMS: GENERAL REQUIREMENTS
API STD 541 : 2014 FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER
NFPA 30 : 2018 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE
ISA RP12.13.02 : 2003 INSTALLATION, OPERATION, AND MAINTENANCE OF COMBUSTIBLE GAS DETECTION INSTRUMENTS
NFPA 77 : 2014 STATIC ELECTRICITY
IEEE 422-2012 IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities
NFPA 325M : 1991 FIRE HAZARD PROPERTIES OF FLAMMABLE LIQUIDS, GASES, AND VOLATILE SOLIDS
NACE RP 01 69 : 2002 CONTROL OF EXTERNAL CORROSION ON UNDERGROUND OR SUBMERGED METALLIC PIPING SYSTEMS
ISA S12.4 : 1970 INSTRUMENT PURGING FOR REDUCTION OF HAZARDOUS AREA CLASSIFICATION
NFPA 54 : 2018 NATIONAL FUEL GAS CODE
NFPA 37 : 2018 INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES
IEEE 515-2011 IEEE Standard for the Testing, Design, Installation, and Maintenance of Electrical Resistance Trace Heating for Industrial Applications
IEEE 141 : 1993 IEEE Recommended Practice for Electric Power Distribution for Industrial Plants
IEEE C57.106-2006 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
CFR 29(PTS1927-END) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
WC 7-1988 CROSS-LINKED-THERMOSETTING-POLYETHYLENE-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
NFPA 497 : 2017 CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS
IEEE 844-2000 IEEE Recommended Practice for Electrical Impedance, Induction, and Skin Effect Heating of Pipelines and Vessels

View more information
US$219.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.