• There are no items in your cart

AS 1143-1973

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

High temperature creosote for the preservation of timber

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

06-30-2017

Language(s)

English

Published date

01-01-1973

Preview

1 - AS 1143-1973 HIGH TEMPERATURE CREOSOTE FOR THE PRESERVATION OF TIMBER - METRIC UNITS
4 - PREFACE
6 - CONTENTS
7 - 1 SCOPE.
7 - 2 TYPES AND PROPERTIES.
7 - 3 SAMPLING.
7 - 3.1 Laboratory Sample.
7 - 3.2 Preliminary Treatment of the Laboratory Sample.
7 - 4 MARKING.
9 - APPENDIX A - METHOD FOR DETERMINATION OF WATER
9 - A1 APPARATUS AND REAGENTS.
9 - A2 PROCEDURE.
9 - A3 REPORT.
10 - APPENDIX B - METHOD FOR DETERMINATION OF MATTER INSOLUBLE IN TOLUENE
10 - B1 APPARATUS AND REAGENTS.
10 - B2 PROCEDURE.
10 - B3 REPORT.
11 - APPENDIX C - METHODS FOR DETERMINATION OF RELATIVE DENSITY*
11 - C1 GENERAL.
11 - C2 METHOD 1 -RELATIVE DENSITY BY DENSITY BOTTLE.
11 - C2.1 Apparatus.
11 - C2.2 Procedure.
12 - C3 METHOD 2 -RELATIVE DENSITY BY BALANCE.
12 - C3.1 Apparatus.
12 - C3.2 Procedure.
12 - C4 METHOD 3 -RELATIVE DENSITY BY HYDROMETER.
12 - C4.1 Apparatus.
12 - C4.2 Procedure.
12 - C4.3 Calculation.
14 - C5 METHOD 4 -RELATIVE DENSITY BY PYCNOMETER.
14 - C5.1 Scope.
14 - C5.2 Apparatus.
14 - C5.3 Calibration of Pycnometers.
15 - C5.4 Procedure for Fractions Entirely Liquid Below 38°C.
16 - C5.5 Procedure for Fractions Containing Solids at 38°C.
16 - C5.6 Procedure for Distillation Residue.
17 - C5.7 Calculations.
17 - C5.8 Report.
17 - C5.9 Precision.
19 - APPENDIX D - METHOD OF TEST FOR DISTILLATION
19 - D1 SUMMARY OF METHOD.
19 - D2 APPARATUS.
23 - D3 PREPARATION OF LABORATORY SAMPLE.
23 - D4 DEHYDRATION OF SAMPLE.
23 - D5 APPARATUS ASSEMBLY.
24 - D6 PROCEDURE.
27 - D7 CALCULATIONS.
27 - D8 REPORT.
27 - D9 PRECISION.
28 - APPENDIX E - METHOD FOR DETERMINATION OF COKE RESIDUE
28 - E1 APPARATUS.
28 - E2 PROCEDURE.
28 - E3 CALCULATIONS.
28 - E4 REPORT.
29 - APPENDIX F - METHOD FOR DETERMINATION OF PHENOLS (TAR ACIDS)
29 - F1 APPARATUS AND REAGENTS.
29 - F2 PROCEDURE.
30 - F3 REPORT.
31 - APPENDIX G - METHOD FOR DETERMINATION OF CLOSED FLASHPOINT
31 - G1 APPARATUS.
31 - G2 PROCEDURE.
31 - G2.1 Drying of Oil.
31 - G2.2 Determination of Flashpoint.
32 - G3 REPORT.
32 - G4 PRECISION.
33 - APPENDIX H - METHOD FOR DETERMINATION OF LIMPID POINT
33 - H1 APPARATUS.
33 - H2 PREPARATION OF SAMPLES.
33 - H3 PROCEDURE.
33 - H4 REPORT.

Applies to creosote obtained from coal tar by high temperature carbonization of coal above 900 degrees Celsius, in two types according to properties determined by tests described in appendices and primarily dependent on source of materials. The creosote is suitable for application by brushing, impregnation or spraying.

This specification applies to creosote obtained from coal tar derived from high temperature carbonization of coal above 900C. The creosote is for the preservation of timber and is intended primarily for land use.

Committee
TM-006
DocumentType
Standard
ISBN
0 7262 4881 9
Pages
27
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

Reconfirmed 1988

AS/NZS 1605:1998 Methods for sampling and analysing timber preservatives and preservative-treated timber
AS 2209-1994 Timber - Poles for overhead lines
AS 1604-1997 Timber - Preservative-treated - Sawn and round
AS 1604-1993 Timber - Preservative-treated - Sawn and round

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.