• There are no items in your cart

AS 1289.3.9.2-2006

Current
Current

The latest, up-to-date edition.

Methods of testing soils for engineering purposes Soil classification tests - Determination of the cone liquid limit of soil - One-point method
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

06-07-2006

This Standard sets out the method for determining the cone liquid limit of a soil using a cone penetrometer and only one measurement of moisture content. This method enables a result to be obtained when only a small amount of soil is available.

This Standard sets out the method for determining the cone liquid limit of a soil using a cone penetrometer and only one measurement of moisture content. This method enables a result to be obtained when only a small amount of soil is available. The definition of liquid limit inherent in this method is not the same as that in the method using the Casagrande apparatus (AS 1289.3.1.1) although the values can be numerically similar (see Note 1).NOTES:1. Using the cone penetrometer, the one-point method is likely to give results that are less reliable than those obtained using the four-point method (see AS 1289.3.9.1) and is therefore suitable only where a less accurate result is acceptable.2. If it is suspected that the liquid limit is higher than about 120%, the method specified in AS 1289.3.9.1 should be followed using the appropriate sample size.

Committee
CE-009
DocumentType
Standard
ISBN
0 7337 7477 6
Pages
5
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS 1289.3.9.2-2006.

AS 1289.2.1.1-2005 Methods of testing soils for engineering purposes Soil moisture content tests - Determination of the moisture content of a soil - Oven drying method (standard method)
AS 1289.3.9.1-2002 Methods of testing soils for engineering purposes Soil classification tests - Determination of the cone liquid limit of a soil
AS 1289.1.1-2001 Methods of testing soils for engineering purposes Sampling and preparation of soils - Preparation of disturbed soil samples for testing
AS 1289.3.1.1-1995 Methods of testing soils for engineering purposes Soil classification tests - Determination of the liquid limit of a soil - Four point Casagrande method

AS 1289.3.4.1-2008 Methods of testing soils for engineering purposes Soil classification tests - Determination of the linear shrinkage of a soil - Standard method
AS 1597.2-2013 Precast reinforced concrete box culverts Large culverts (exceeding 1200 mm span or 1200 mm height and up to and including 4200 mm span and 4200 mm height)
HB 160-2006 Soils testing
AS/NZS 3725:2007 Design for installation of buried concrete pipes
AS 1289.5.2.1:2017 Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using modified compactive effort
AS 1289.3.3.2-2009 Methods of testing soils for engineering purposes Soil classification tests - Calculation of the cone plasticity index of a soil (Reconfirmed 2022)
AS 1289.5.1.1:2017 Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using standard compactive effort
AS 3727.1:2016 Pavements Residential

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.