• There are no items in your cart

AS 1684.2 N1/N2 Supp 1-2010

Current
Current

The latest, up-to-date edition.

Residential timber-framed construction Non-cyclonic areas, N1/N2 Supplement 1: Timber framing span tables - Wind classification, N1/N2 - Seasoned softwood - Stress Grade F5 (Supplement to AS 1684.2-2010)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

06-21-2010

Preview

1 - F5 Seasoned Softwood
5 - [1-32] Single or Upper Storey
5 - [1-5] Floor Bearers
5 - [1] Supporting single or upper storey loadbearing walls - FLW 1200
6 - [2] Supporting single or upper storey loadbearing walls - FLW 2400
7 - [3] Supporting single or upper storey loadbearing walls - FLW 3600
8 - [4] Supporting single or upper storey loadbearing walls - FLW 4800
9 - [5] Supporting floor load only
10 - [6] Floor Joists
11 - [7-13] Wall Studs
11 - [7] Wall studs - Not notched single or upper storey
12 - [8] Wall studs - Notched 20mm single or upper storey
13 - [9] Studs supporting concentrated loads - Not notched
13 - [10] Studs supporting concentrated loads - Notched to 20mm
14 - [11] Jamb studs - Single or upper storey
16 - [12] Internal loadbearing wall studs - Not notched single or upper storey
17 - [13] Internal loadbearing wall studs - Notched to 20mm single or upper storey
18 - [14-16] Plates
18 - [14] Bottom Plates - Supporting single or upper storey
19 - [15] Top Plates - Single or upper storey sheet roof
20 - [16] Top Plates - Single or upper storey tile roof
21 - [17-20] Lintels
21 - [17] Sheet roof - Single or upper storey load bearing walls
22 - [18] Tile roof - Single or upper storey load bearing walls
23 - [19] Sheet roof - Supporting concentrated roof loads
24 - [20] Tile roof - Supporting concentrated roof loads
25 - [21-22] Ceiling Joists
25 - [21] Supporting ceiling loads, no over batten
25 - [22] Supporting ceiling loads, with over batten
26 - [23] Hanging Beams - Supporting ceiling loads
26 - [24] Counter Beams
27 - [25] Strutting/Hanging Beams - Supporting roof and ceiling loads
28 - [26] Strutting/Counter Beams - Supporting root and ceiling loads
28 - [27] Strutting Beams
29 - [28] Underpurlins
30 - [29] Rafters or Purlins
32 - [30-31] Ridge or Intermediate Beams
32 - [30] Single span
34 - [31] Continuous span
36 - [32] Roof Battens - Supporting roofing only
37 - [33-48] Lower Storey of Two Storey
37 - [33-35] Floor Bearers
37 - [33] Supporting two storey loadbearing walls - FLW 1800
38 - [34] Supporting two storey loadbearing walls - FLW 3600
39 - [35] Lower storey of two storey - Supporting upper and lower floor loads only
40 - [36-44] Wall Studs
40 - [36] Wall studs - Not notched lower storey loadbearing walls
41 - [37] Wall studs - Notched to 20mm lower storey loadbearing walls
42 - [38] Studs - Not notched - Supporting concentrated floor loads
42 - [39] Studs - Notched to 20mm - Supporting concentrated floor loads
43 - [40] Jamb studs - Lower storey of two storey - FLW 1800
44 - [41] Jamb studs - Lower storey of two storey - FLW 3600
45 - [42] Jamb studs - Lower storey of two storey - FLW 4800
46 - [43] Wall studs - Not notched supporting floor loads only
46 - [44] Wall studs - Notched to 20mm supporting floor loads only
47 - [45-46] Plates
47 - [45] Bottom plates - Lower storey of two storey
48 - [46] Top plates - Lower storey of two storey
49 - [47-48] Lintels
49 - [47] Lower storey loadbearing walls - Sheet roof
50 - [48] Lower storey loadbearing walls - Tile roof
51 - [49-53] Verandahs, Posts and Decks
51 - [49] Deck Bearers
51 - [50] Deck Joists
52 - [51A-52A] Verandahs Beams
52 - [51A] Single span
54 - [52A] Continuous span
56 - [53] Posts Supporting and/or Floor Loads

This is a Supplement to AS 1684.2-2010 and AS 1684.2:2021; Residential timber-framed construction - Part 2: Non-cyclonic areas. The Supplement provides timber framing span tables for wind classification N1/N2 for seasoned softwood - Stress Grade F5.

Committee
TM-002
DocumentType
Supplement (Main)
ISBN
978 0 7337 9491 9
Pages
52
PublisherName
Standards Australia
Status
Current
SupersededBy
Supersedes

First published as AS 1684 Supp 9-1975.Second edition 1992.Revised and redesignated as AS 1684.2 N1/N2 Supplement 1-1999.Third edition 2006.Fourth edition 2010. Originated as AS 1684 Supp 9-1975. Second edition 1992. Revised and redesignated as AS 1684.2 N1/N2 Supp 1-1999. Third edition 2006. Fourth edition 2010.

AS 4654.2-2012 Waterproofing membranes for external above-ground use Design and installation
AS/NZS 1748.1:2011 Timber - Solid - Stress-graded for structural purposes General requirements
AS 4773.2-2010 Masonry in small buildings - Construction
AS 4773.1-2010 Masonry in small buildings - Design
WS11-2012 Timber-framed Systems for External Noise
AS 1884-2012 Floor coverings - Resilient sheet and tiles - Installation practices
AS 3818.8-2010 Timber - Heavy structural products - Visually graded Stumps and sole plates
WS12-2012 Impact Assessment for Moisture-affected Timber-framed Construction
WS14-2012 Timber in Internal Design
WS13-2012 Finishing Timber Externally

View more information
US$7.69
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.