• There are no items in your cart

AS 1828-1984

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Electrical equipment for explosive atmospheres - Cable glands
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

06-25-2021

Published date

01-01-1984

Preview

1 - AS 1828-1984 ELECTRICAL EQUIPMENT FOR EXPLOSIVE ATMOSPHERES - CABLE GLANDS
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - SECTION 1. SCOPE AND GENERAL
7 - 1.1 SCOPE.
7 - 1.2 REFERENCED DOCUMENTS.
7 - 1.3 DEFINITIONS.
7 - 1.3.1 Cable gland
7 - 1.3.2 Flexible cable
7 - 1.3.3 Flexible cord
7 - 1.3.4 Sealing bush
7 - 1.3.5 Type of protection
7 - 1.4 GROUPING.
8 - SECTION 2. DESIGN, CONSTRUCTION AND MARKING
8 - 2.1 DESIGN
8 - 2.1.1 General.
8 - 2.1.2 Corrosion protection.
8 - 2.1.3 Maintenance of electrical continuity.
8 - 2.1.4 Maintenance of sealing properties.
8 - 2.1.5 Glands for Group II.
8 - 2.2 MATERIALS.
8 - 2.3 WALL THICKNESS.
8 - 2.4 FIT OF CABLE SHEATH.
8 - 2.5 GLANDS WITH SEALING BUSHES.
8 - 2.5.1 General.
8 - 2.5.2 Properties of bush.
8 - 2.5.3 Sealing bush.
8 - 2.5.4 Compression of bush.
8 - 2.6 GLANDS WITH COMPOUND SEALING.
8 - 2.6.1 General.
8 - 2.6.2 Sealing compound.
8 - 2.6.3 Formation of seal.
8 - 2.6.4 Assembly of seal.
8 - 2.7 JOINTS.
8 - 2.7.1 General.
9 - 2.7.2 Screwed joints.
9 - 2.7.3 Spigot joints.
9 - 2.8 ATTACHMENT OF CABLES AND FLEXIBLE CORDS.
9 - 2.8.1 Lead-alloy sheathed cable.
9 - 2.8.2 Wire-armoured cable.
9 - 2.8.3 MIMS cable.
9 - 2.8.4 Rubber or PVC sheathed (unscreened) cable or cord.
9 - 2.8.5 Metal-screened flexible cable or cord.
10 - 2.9 GLAND ASSEMBLY.
10 - 2.10 MARKING.
11 - SECTION 3. TESTS
11 - 3.1 GENERAL.
11 - 3.2 DIMENSIONAL TESTS.
11 - 3.2.1 Agreement with drawings.
11 - 3.2.2 Breadth of joint surfaces.
11 - 3.2.3 Gap between joint surfaces.
11 - 3.2.4 Deviation from a plane surface.
11 - 3.3 TORQUE TEST.
11 - 3.4 TENSION FORCE TEST.
11 - 3.5 DEGREE OF PROTECTION TEST.
12 - 3.6 MECHANICAL PRESSURE TEST.
12 - 3.7 IMPACT TEST.
13 - APPENDIX A - TYPICAL CONSTRUCTION METHODS FOR CABLE GLANDS
17 - APPENDIX B - TENSION FORCE TEST
17 - APPENDIX C - PROOF TORQUE TEST
17 - APPENDIX D - INFORMATION TO BE CONTAINED IN DRAWINGS OF GLAND SUBMITTED WITH AN APPLICATION FOR EXAMINATION AND TEST

Specifies requirements relating to the design, construction, performance and testing of cable glands for use with enclosures installed in explosive atmospheres.

This standard specifies requirements relating to the design, construction, performance and testing of cable glands for use with enclosures installed in explosive atmospheres. It prescribes requirements considered to be essential to secure reliability of glands in service.The tests specified herein are intended as type tests to prove a particular design for compliance with the standard.

Committee
EL-014
DocumentType
Standard
ISBN
0 7262 1835 9
Pages
11
PublisherName
Standards Australia
Status
Withdrawn
SupersededBy
Supersedes

Superseded on 15 March 2004Under Revision See DR 94110

AS 3811-1998 Hard-wired patient alarm systems
AS 2381.1-1991 Electrical equipment for explosive atmospheres - Selection, installation and maintenance - General requirements
AS 2381.10-1995 Electrical equipment for explosive atmospheres - Selection, installation and maintenance - Equipment in combustible dust (Class II) areas
AS 2201.1-1998 Intruder alarm systems Systems installed in client’s premises
AS 2381.2-1993 Electrical equipment for explosive atmospheres - Selection, installation and maintenance - Flameproof enclosure d
AS/NZS 3188:1995 Approval and test specification - Terminations and glands for mineral-insulated metal-sheathed cables
AS 2067-1984 Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV
AS 2380.2-1991 Electrical equipment for explosive atmospheres - Explosion-protection techniques Flameproof enclosure d
AS 2381.6-1993 Electrical equipment for explosive atmospheres - Selection, installation and maintenance Increased safety e
AS 2989-1992 Electrical equipment for coal mines - Specific requirements for high voltage circuit-breakers and disconnectors
AS/NZS 2843.1:2000 Timber preservation plant safety code - Plant design
AS 1300-1989 Electrical equipment for coal mines - Bolted flame-proof cable coupling devices
AS 1299-1993 Electrical equipment for coal mines - Flameproof restrained plugs and receptacles
AS 2595.1-1992 Electrical equipment for coal mines - Electrical requirements for underground mining machines and accessories - Equipment for use in hazardous areas
AS/NZS 2381.2:2006 Electrical equipment for explosive atmospheres - Selection, installation and maintenance Flameproof enclosure d
HB 13-2000 Electrical equipment for hazardous areas
AS/NZS 60079.14:2009 Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD)
SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.