Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices (Reconfirmed 2020)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-18-2022

Published date

12-09-2009

Preview

Specifies the design and test requirements for bolted explosion-protected three-phase cable coupling devices and adaptors of the pin and socket type, referred to in This Standard as ‘cable coupling devices’, for use with restricted earth-fault systems in mines and quarries. The devices are designed to couple cables together, or to couple a cable to equipment.

This Standard specifies the design and test requirements for bolted explosion-protected three-phase cable coupling devices and adaptors of the pin and socket type, referred to in this Standard as ‘cable coupling devices’, for use with restricted earth-fault systems in mines and quarries. The devices are designed to couple cables together, or to couple a cable to equipment.Cable coupling devices and adaptors constructed to this Standard are not intended to be coupled or uncoupled while the circuit is energized.The Standard covers two types of coupling devices:(a) Type ADesigned according to Figures in this Standard that prescribe the dimensions necessary to interconnect cable coupling devices from different manufacturers.(b) Type BDesigned to dimensions that are not compatible with Type A coupling devices. Type B couplers cannot be directly coupled to Type A coupling devices under normal operation. Type B plugs and receptacles do not comply with Figures 4.1 to 4.5 but comply with all other requirements of this Standard. Where there is a variation to a particular clause for Type B plugs and receptacles it is specifically stated. The use of transition devices between Type A and Type B systems is permitted.This Standard also deals with some electrical and mechanical requirements, including the provision of earthed phase barriers to protect against interphase faults. It does not specify fully detailed designs.NOTES:Appendix A lists the information a user should provide with any enquiry or order.Appendix C lists the information that should be supplied by the designer or manufacturer.

Committee
EL-023
DocumentType
Standard
ISBN
0 7337 9330 4
Pages
26
ProductNote
Reconfirmed 11/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 11/09/2020
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Originated as AS 1300-1973.
Previous edition 1989.
Jointly revised and designated as AS/NZS 1300:2009.
Reconfirmed 2020. Originated as AS 1300-1973. Previous edition 1989. Jointly revised and designated as AS/NZS 1300:2009. Reissued incorporating Amendment No. 1 (March 2012).

AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
AS/NZS 1972:2006 Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020)
AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
AS 2700-1996 Colour Standards for general purposes - Swatches
AS/NZS 60079.7:2006 Explosive atmospheres Equipment protection by increased safety 'e'
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS/NZS 60079.1.1:2002 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd' - Method of test for ascertainment of maximum experimental safe gap
AS 60270-2001 High-voltage test techniques - Partial discharge measurements
AS/NZS 60079.18:2005 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection encapsulation m electrical apparatus
AS/NZS 60079.1:2007 Explosive atmospheres Equipment protection by flameproof enclosures 'd'
AS/NZS 60079.0:2008 Explosive atmospheres Equipment - General requirements
AS/NZS 3008.1.1:2009 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS 1856-2004 Electroplated coatings - Silver
AS 60529-2004 Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018)
AS/NZS 1747:2022 Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories

SA/SNZ HB 146:2018 Management of electrical cable in mines and quarries
AS/NZS 4871.2:2010 Electrical equipment for mines and quarries Distribution, control and auxiliary equipment
AS/NZS 4871.1:2010 Electrical equipment for mines and quarries General requirements
AS/NZS 2290.1:2014 Electrical equipment for coal mines - Introduction, inspection and maintenance For hazardous areas
HB 239:2011 Guidance on the repair and overhaul of electrical equipment for explosive atmospheres
AS/NZS 4871.1:2012 Electrical equipment for mines and quarries General requirements
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations

View more information
US$55.47
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.