AS/NZS 1530.7:1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Methods for fire tests on building materials, components and structures Smoke control door and shutter assemblies - Ambient and medium temperature leakage test procedure

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

04-27-2023

Language(s)

English

Published date

11-05-1998

Preview

1 - AS/NZS 1530.7:1998 METHODS FOR FIRE TESTS ON BUILDING MATERIALS, COMPONENTS AND STRUCTURES - SMOKE CONTROL DOOR AND SHUTTER ASSE
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
6 - 1.2 APPLICATION
6 - 1.3 OBJECTIVES
6 - 1.4 REFERENCED DOCUMENTS
6 - 1.5 DEFINITIONS
6 - 1.5.1 Door and shutter assembly
6 - 1.5.2 Smoke control door
6 - 1.5.3 Ambient temperature
6 - 1.5.4 Medium temperature
6 - 1.5.5 Leakage rate
7 - 1.5.6 Pressure difference
7 - 1.5.7 Test specimen
7 - 1.5.8 Associated construction
7 - 1.5.9 Supporting construction
7 - 1.6 SYMBOLS
8 - SECTION 2 TEST METHOD
8 - 2.1 SCOPE OF SECTION
8 - 2.2 TEST APPARATUS
8 - 2.3 INSTRUMENTATION
8 - 2.3.1 Differential pressure
8 - 2.3.2 Air temperature
8 - 2.3.3 Airflow
8 - 2.4 TEST SPECIMEN
8 - 2.4.1 Number
9 - 2.4.2 Size
9 - 2.4.3 Construction
9 - 2.4.4 Conditioning
9 - 2.4.5 Pre-test analysis
9 - 2.5 TEST PROCEDURE
9 - 2.5.1 Setting-up procedure
10 - 2.5.2 Air leakage test
10 - 2.6 OBSERVATIONS
10 - 2.6.1 Deformation
11 - SECTION 3 REPORTING OF RESULTS
11 - 3.1 EXPRESSION OF RESULTS
11 - 3.1.1 General
11 - 3.1.2 Measured values
11 - 3.1.3 Standard conditions
13 - 3.2 TEST REPORT
14 - APPENDIX A - TEST PRINCIPLE
15 - APPENDIX B - TEST APPARATUS
15 - B1 TEST APPARATUS
15 - B2 TEST CHAMBER

Sets out test procedures for a method of test for determining the smoke leakage through doors and shutters. This Standard is based on but not equivalent to ISO/CD 5925-1.

This Standard sets out a method to measure the leakage of cold and warm smoke from one side of a door assembly to the other under the specified test conditions. The test can be applied to door and shutter assemblies of different types intended for purposes of controlling the passage of smoke in case of fire and of providing fire resistance.

Committee
FP-018
DocumentType
Standard
ISBN
0 7337 2216 4
Pages
11
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS/NZS 1530.7:1998.

AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
AS 1905.2-2005 Components for the protection of openings in fire-resistant walls Fire-resistant roller shutters (Reconfirmed 2016)
AS 1905.1-2005 Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
AS 4072.1-2005 Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints (Reconfirmed 2016)

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.