Limits of electromagnetic interference from overhead a.c. powerlines and high voltage equipment installations in the frequency range 0.15 to 1000 MHz

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Published date

01-01-1997

Preview

1 - AS/NZS 2344:1997 LIMITS OF ELECTROMAGNETIC INTERFERENCE FROM OVERHEAD A.C. POWERLINES AND HIGH VOLTAGE EQUIPMENT...
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE AND APPLICATION
6 - 1.1 Scope
6 - 1.2 Application
6 - 2 REFERENCED DOCUMENTS
7 - 3 DEFINITIONS AND ACRONYMS
7 - 3.1 Definitions
7 - 3.1.1 Corridor
7 - 3.1.2 Easement (also known as right-of-way)
7 - 3.1.3 Fair weather
7 - 3.1.4 Fog or mist
7 - 3.1.5 Ice
7 - 3.1.6 Protection distance (corridor boundary)
7 - 3.1.7 Protection ratio
7 - 3.1.8 Rain
7 - 3.1.9 Rural area
8 - 3.1.10 Snow
8 - 3.1.11 System voltage
8 - 3.1.12 Urban area
8 - 3.1.13 Useable signal strength
8 - 3.2 Acronyms
8 - 4 OPERATING CONDITIONS
8 - 5 LIMITS
8 - 5.1 Overhead lines
9 - 5.2 High voltage equipment installations
9 - 6 MEASURING APPARATUS
9 - 7 TEST METHODS
11 - 8 COMPLIANCE
11 - 8.1 80/80 rule (preferred method)
12 - 8.2 Alternative method
12 - 8.2.1 Application
12 - 8.2.2 Weather corrections
12 - 8.2.3 Seasonal variations
13 - 8.3 Test conditions
13 - 8.4 Background noise
13 - 8.5 Measurement uncertainty
15 - APPENDIX A - DERIVATION OF LIMITS OF RADIO DISTURBANCE
15 - A1 SCOPE
15 - A2 GENERAL
18 - APPENDIX B - LIMITS OF RADIO DISTURBANCE ABOVE 30 MHz
18 - B1 SCOPE
18 - B2 LIMITS OF DISTURBANCE
19 - B3 METHOD OF MEASUREMENT

Specifies electromagnetic emission limits for a.c. overhead power lines and high voltage equipment, and methods of measurement to ascertain compliance.

This Standard establishes limits for electromagnetic interference (radio disturbance) from alternating current (a.c.) overhead powerlines and high voltage equipment installations in the frequency range 0.15 to 1000 MHz. The limits are specified in accordance with geographical zones and coverage areas. Australia and New Zealand are situated in Zone 3 and various coverage areas within those zones are in accordance with Figure 1. These limits are specified for the protection of broadcast radio reception and other radio communication services, including navigation and safety-of-life services.The limits assume the powerlines and equipment installations have a defined corridor or boundaries within which radio reception cannot be guaranteed and where special measures may be taken.Outside these boundaries, a satisfactory level of reception, as defined by the International Telecommunication Union (ITU), can be expected.Limits for single components of powerlines and equipment installations are under consideration.ApplicationThis publication applies to a.c. powerlines and high voltage equipment installations used in power systems for the generation, transmission and distribution of electric energy.Compliance of individual system components to the limits stated for these components does not imply compliance with system limits. However, the compliance of a component with its respective limit is a guide to the likely performance of the component when incorporated into a power system and a quantitative measure of electromagnetic interference quality for design and contractual purposes.The limits set down herein are achievable by powerlines and high voltage installations with components in good working condition. Radio disturbance generated by faulty components (i.e. bad contacts or cracked insulators) may be expected to exceed these limits.

Committee
TE-003
DocumentType
Standard
ISBN
0 7337 1392 0
Pages
18
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published in Australia as AS 2344-1980.Jointly revised and designated AS/NZS 2344:1997. First published in Australia as AS 2344-1980. Jointly revised and designated AS/NZS 2344:1997.

AS/NZS 1052:1992 CISPR specification for radio interference measuring apparatus and measurement methods
AS 2344-1980 Limits of electromagnetic interference from overhead a.c. power lines

AS 60044.2-2007 Instrument transformers Inductive voltage transformers (IEC 60044-2:Ed.1.2 (2003) MOD)
AS 4191-1994 Portable traffic signal systems
AS/NZS 7000:2016 Overhead line design
AS 3516.1-1988 Siting of radiocommunications facilities - LF, MF and HF transmitting and HF receiving facilities
AS 60044.1-2007 Instrument transformers Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD)
HB 331-2012 Overhead line design
AS 2067-2008 Substations and high voltage installations exceeding 1 kV a.c.
AS/NZS 7000:2010 Overhead line design - Detailed procedures
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
AS 4192-2006 Illuminated flashing arrow signs
AS/NZS 1052:1992 CISPR specification for radio interference measuring apparatus and measurement methods

View more information
US$60.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.