• There are no items in your cart

AS/NZS 2430.3.9:2004

AvailableSuperseded
AvailableSuperseded

An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by Intertek Inform as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

Classification of hazardous areas Examples of area classification - Miscellaneous
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-20-2004

Preview

Specifies guidance on the classification of areas associated with several finishing processes, fruit ripening rooms, several batch-type processes and ammonia systems. It includes specific examples of classification for the aforementioned areas. To be read in conjunction with AS/NZS2430.1.

This Standard provides examples of area classification for areas associated with specialised processes other than those covered by Parts 3.2 to 3.8 of AS/NZS 2430.3. It is part of the AS/NZS 2430.3 series, which recommends the classification of several commonly occurring situations and should be read in conjunction with AS/NZS 2430.3.1.

Committee
MS-011
DocumentType
Standard
ISBN
0 7337 5976 9
Pages
17
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes

First published in Australia as part of AS 1076.2-1977.AS 2430.1 first published 1981.AS 1076.2-1977 and AS 2430.1-1981 revised, amalgamated and designated and designated AS 2430.1-1982.AS 2430.1-1982 revised and redesignated in part as AS 2430.3-1987.Second edition 1991.First published in New Zealand as part of NZS 6101P:1972.Revised and redesignated in part as NZS 6101.3:1991.AS 2430.3-1991 and NZS 6101.3:1991 revised, amalgamated and redesignated in part as AS 2430.3.9:1997.Second edition 2004. Originated in Australia as part of AS 1076.2-1977. Originated in New Zealand as part of NZS 6101P:1972. Previous edition AS/NZS 2430.3.9:1997. Second edition 2004.

AS/NZS 4114.1:2003 Spray painting booths, designated spray painting areas and paint mixing rooms Design, construction and testing
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS/NZS 1677.1:1998 Refrigerating systems - Refrigerant classification
AS/NZS 2430.3.1:2004 Classification of hazardous areas Examples of area classification - General
AS/NZS 61241.3:1999 Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present
AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
AS 3754-1990 Safe application of powder coatings by electrostatic spraying
AS 1482-1985 Electrical equipment for explosive atmospheres - Protection by ventilation - Type of protection v (Reconfirmed 2013)
AS/NZS 1677.2:1998 Refrigerating systems Safety requirements for fixed applications

AS 4976-2008 The removal and disposal of underground petroleum storage tanks
AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
AS/NZS 1596:2002 The storage and handling of LP Gas
AS/NZS 4114.1:2003 Spray painting booths, designated spray painting areas and paint mixing rooms Design, construction and testing
AS/NZS 2311:2009 Guide to the painting of buildings
HB 29-2007 Communications cabling manual - Module 2: Communications cabling handbook
AS 4326-2008 The storage and handling of oxidizing agents
AS/NZS 2243.10:2004 Safety in laboratories Storage of chemicals
AS/NZS 1768:2007 Lightning protection
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS/NZS 4114.2:2003 Spray painting booths, designated spray painting areas and paint mixing rooms - Installation and maintenance
AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
AS 2714-2008 The storage and handling of organic peroxides (Reconfirmed 2021)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3780-2008 The storage and handling of corrosive substances
AS/NZS 60079.30.2:2007 Explosive atmospheres Electrical resistance trace heating - Application guide for design, installation and maintenance (IEC 60079-30-2, Ed. 1.0 (2007) MOD)
AS/NZS 4240.1:2009 Remote control systems for mining equipment Design, construction, testing, installation and commissioning (Reconfirmed 2021)
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance - General requirements
AS/NZS 3788:2006 Pressure equipment - In-service inspection (Reconfirmed 2017)
AS 5034-2005 Installation and use of inert gases for beverage dispensing
HB 13-2007 Electrical equipment for hazardous areas
AS/NZS 2381.2:2006 Electrical equipment for explosive atmospheres - Selection, installation and maintenance Flameproof enclosure d
AS/NZS 2243.2:2006 Safety in laboratories Chemical aspects

View more information
US$69.34
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.