• There are no items in your cart

AS/NZS 2802:2000

Current
Current

The latest, up-to-date edition.

Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

06-19-2000

Preview

Specifies the requirements for two classes of multicore elastomer insulated and sheathed flexible reeling and trailing cables for surface mining, underground mining (other than coal mining) and general use, where movable plant requires electricity supply at system voltages from 1.1/1.1kV up to and including 33/33kV.

This Standard specifies requirements for two classes of multicore elastomer insulated and sheathed flexible reeling and trailing cables for surface mining, underground mining (other than coal mining) and general use, where plant requires electricity supply at system voltages from 1.1/1.1 kV up to and including 33/33 kV.The Class 1 cables are insulated with a high grade ethylene propylene rubber (XR-EP-90) which permits a reduced radial thickness for the insulation compared with equivalent rated Class 2 cables. The cable sheath is extra-heavy duty chlorosulphonated polyethylene, or chlorinated polyethylene (XHD-90-CSP, or CPE), or polychloroprene (XHD-85-PCP).The Class 2 cables are designed for manufacture using standard R-EP-90 insulation and HD-90-CSP, HD-90-CPE or HD-85-PCP sheath. The greater insulation radial thickness required for these cables provides a more robust cable.It is not intended that the use of other types of cables should be precluded and regulatory authorities may give approval to new types as they are developed. Appropriate requirements for new types and sizes will eventually be included in this Standard as the need arises.This Standard also provides the basis of requirements for construction of other sizes in the range of materials covered by this Standard.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 3436 7
Pages
54
ProductNote
Reconfirmed 11/09/2020.
This standard has been reconfirmed in Australia in 2020 and remains current in New Zealand. Reconfirmation Notice 11/09/2020
PublisherName
Standards Australia
Status
Current
Supersedes
UnderRevision

First published in Australia as AS C81-1941.
Second edition 1950.
Third edition 1952.
Fourth edition 1967.
Fifth edition 1973.
Revised and redesignated AS 1802-1976.
Revised and redesignated as AS 2802-1985.
Second edition 1992.
Jointly revised and redesignated as AS/NZS 2802:2000.
Reconfirmed 2020. Originated in Australia as AS C81-1941. Previous edition in Australia AS 2802-1992. Previous edition in New Zealand NZS/AS 2802-1992. Jointly revised and designated AS/NZS 2802:2000. Reissued incorporating Amendment No. 1 (December 2003).

AS/NZS 1660.4:1998 Test methods for electric cables, cords and conductors Complete cable and flexible cord (Reconfirmed 2017)
AS/NZS 1802:1995 Electric cables - Reeling and trailing - For underground coal mining purposes
AS 3007.2-1987 Electrical installations - Surface mines and associated processing plant - General protection requirements
AS/NZS 1660.2.5:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to cables above 1 kV (Reconfirmed 2017)
AS/NZS 1660.2.3:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to PVC and halogen free thermoplastic materials (Reconfirmed 2017)
AS/NZS 1660.5.1:1998 Test methods for electric cables, cords and conductors Fire tests - Tests on bunched cables
AS/NZS 1660.5.2:1998 Test methods for electric cables, cords and conductors Fire tests - Smoke density
AS/NZS 1660.2.2:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to elastomeric, XLPE and XLPVC materials (Reconfirmed 2017)
AS/NZS 1660.1:1998 Test methods for electric cables, cords and conductors Conductors and metallic components (Reconfirmed 2017)
AS 3007.5-1987 Electrical installations - Surface mines and associated processing plant - Operating requirements
AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
AS/NZS 1660.5.6:1998 Test methods for electric cables, cords and conductors Fire tests - Test for combustion propagation
AS/NZS 1660.5.5:1998 Test methods for electric cables, cords and conductors Fire tests - Circuit integrity under fire conditions
AS/NZS 5000.1:1999 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 kV
AS/NZS 1660.5.3:1998 Test methods for electric cables, cords and conductors Fire tests - Determination of the amount of halogen acid gas evolved during the combustion of polymeric materials taken from cables
AS/NZS 3863:2002 Galvanized mild steel wire for armouring of cables
AS 3007.4-1987 Electrical installations - Surface mines and associated processing plant - Additional requirements for specific applications
AS/NZS 1660.2.4:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to polyethylene and polypropylene materials (Reconfirmed 2017)
AS 3863-1991 Galvanized mild steel wire for armouring cables
AS/NZS 1660.2.1:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application (Reconfirmed 2017)
AS/NZS 1660.5.4:1998 Test methods for electric cables, cords and conductors - Fire tests - Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity
AS/NZS 1660.3:1998 Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017)
AS 3007.1-1987 Electrical installations - Surface mines and associated processing plant - Scope and definitions
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 1125-1993 Conductors in insulated electric cables and flexible cords
AS 3007.3-1987 Electrical installations - Surface mines and associated processing plant - General requirements for equipment and ancillaries
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
AS/NZS 1747:2022 Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories

AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
SA/SNZ HB 146:2018 Management of electrical cable in mines and quarries
AS/NZS 1300:2009 Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices (Reconfirmed 2020)
AS/NZS 4871.1:2010 Electrical equipment for mines and quarries General requirements
AS/NZS 4761.2:2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Guide to assessing competency
AS/NZS 2081:2011 Electrical protection devices for mines and quarries (Reconfirmed 2022)
AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
HB 239:2011 Guidance on the repair and overhaul of electrical equipment for explosive atmospheres
AS/NZS 4761.1:2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Competency Standards
AS/NZS 1802:2018 Electric cables - Reeling and trailing - For underground coal mining
AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
AS/NZS 3012:2003 Electrical installations - Construction and demolition sites
AS 2067:2016 Substations and high voltage installations exceeding 1 kV a.c.
AS/NZS 1747:2003 Reeling, trailing and feeder cables used for mining - Repair, testing and fitting of accessories (Reconfirmed 2020)
AS/NZS 4871.1:2012 Electrical equipment for mines and quarries General requirements
AS/NZS 1299:2009 Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV (Reconfirmed 2020)
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant
SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)

View more information
US$118.31
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.