• There are no items in your cart

AS/NZS 3004:2002

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electrical installations - Marinas and pleasure craft at low-voltage
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-20-2023

Language(s)

English

Published date

05-30-2002

Preview

1 - AS/NZS 3004:2002 ELECTRICAL INSTALLATIONS-MARINAS AND PLEASURE CRAFT AT LOW-VOLTAGE
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 REFERENCED DOCUMENTS
8 - 1.4 DEFINITIONS
8 - 1.4.1 Detachable connection
8 - 1.4.2 Direct connection
8 - 1.4.3 Galvanic isolator
8 - 1.4.4 Marina
8 - 1.4.5 Pleasure craft
8 - 1.4.6 Service pillar
8 - 1.5 ALTERATIONS, ADDITIONS AND REPAIRS
9 - 1.6 MARINE ENVIRONMENT ELECTRICAL SAFETY CONSIDERATIONS
9 - 1.6.1 Scope
9 - 1.6.2 Additional risk factors
9 - 1.6.3 Additional protection for equipment
9 - 1.6.4 Unacceptable measures against electric shock
9 - 1.7 MINIMIZATION OF GALVANIC CORROSION
9 - 1.8 ACCEPTABLE METHODS OF CONNECTION TO PLEASURE CRAFT
11 - SECTION 2 MARINA ELECTRICAL INSTALLATION
11 - 2.1 WIRING DETAILS
11 - 2.1.1 General
11 - 2.1.2 Selection of electrical wiring systems
11 - 2.1.3 Earthing system
12 - 2.2 MAXIMUM DEMAND
12 - 2.2.1 Mains and submains
12 - 2.3 ISOLATING TRANSFORMERS
12 - 2.3.1 General
12 - 2.3.2 Protection
12 - 2.4 SWITCHBOARDS PROVIDING LOW-VOLTAGE ELECTRICAL SUPPLY TO PLEASURE CRAFT
12 - 2.4.1 General
12 - 2.4.2 Service pillars
15 - 2.4.3 Other switchboards
15 - 2.5 OTHER SOCKET-OUTLETS
15 - 2.6 TESTING OF RESIDUAL CURRENT DEVICES (RCDs)
15 - 2.6.1 Testing regime
15 - 2.6.2 Recording of results
16 - SECTION 3 PLEASURE CRAFT LOW-VOLTAGE ELECTRICAL INSTALLATION
16 - 3.1 GENERAL
16 - 3.2 MULTIPLE CONNECTIONS
16 - 3.2.1 Common method of connection
16 - 3.2.2 Arrangement and control
16 - 3.3 PROVISION FOR CONNECTION TO THE MARINA LOW-VOLTAGE ELECTRICAL SUPPLY
16 - 3.3.1 Detachable connection at the pleasure craft
17 - 3.3.2 Direct connection at the pleasure craft
17 - 3.4 CONTROL AND PROTECTION
17 - 3.4.1 Switchboards
17 - 3.4.2 Switchboard isolation
17 - 3.4.3 Circuit overcurrent protection
17 - 3.4.4 Location
18 - 3.4.5 Prohibited protective devices
18 - 3.5 WIRING SYSTEM
18 - 3.5.1 Size and type of cable
18 - 3.5.2 Protection from damage
18 - 3.5.3 Fixing
18 - 3.5.4 Access to connections
18 - 3.5.5 Dual supply systems changeover interlock
19 - 3.6 EARTHING AND BONDING
19 - 3.6.1 General
19 - 3.6.2 Resistance
19 - 3.6.3 Metallic pipes and conduits
19 - 3.6.4 Supply through a shore-mounted isolating transformer
19 - 3.6.5 Supply through an on-board isolating transformer
20 - 3.6.6 Supply without an isolating transformer
20 - 3.6.7 Galvanic isolator
20 - 3.6.8 Neutral requirements
20 - 3.7 ACCESSORIES
20 - 3.7.1 Mounting
20 - 3.7.2 Switches
20 - 3.7.3 Socket-outlets
21 - 3.7.4 Output terminals
21 - 3.8 PERMANENTLY CONNECTED APPLIANCES
21 - 3.8.1 Control
21 - 3.8.2 Over-temperature cut-out
21 - 3.9 EXTRA-LOW-VOLTAGE TRANSFORMERS
21 - 3.10 ELECTRICAL INSTALLATIONS IN AREAS CONTAINING A BATH OR SHOWER
21 - 3.11 LIGHTNING PROTECTION SYSTEMS
22 - 3.12 TESTING
23 - SECTION 4 CONNECTION OF A PLEASURE CRAFT TO A MARINA LOW-VOLTAGE ELECTRICAL INSTALLATION
23 - 4.1 SUPPLY LEAD
23 - 4.1.1 General
23 - 4.1.2 Technical details
23 - 4.1.3 Length
24 - 4.1.4 Coiled leads
24 - 4.2 INSTALLATION OF SUPPLY LEAD
24 - 4.3 EARTHING
24 - 4.3.1 Supply through a shore-mounted isolating transformer
25 - 4.3.2 Supply through an on-board isolating transformer
25 - 4.3.3 Supply without an isolating transformer
26 - APPENDIX A - BERTHING INSTRUCTIONS FOR CONNECTION TO THE MARINA LOW-VOLTAGE ELECTRICAL SUPPLY THROUGH A SHORE-MOUNTED...
27 - APPENDIX B - BERTHING INSTRUCTIONS FOR CONNECTION TO THE MARINA LOW-VOLTAGE ELECTRICAL SUPPLY THROUGH AN ON-BOARD...
29 - APPENDIX C - MARINA LOW-VOLTAGE ELECTRICAL SUPPLY CONFIGURATIONS
29 - C1 INTRODUCTION
31 - APPENDIX D - CALCULATION OF MAXIMUM DEMAND
31 - D1 INTRODUCTION
31 - D2 PROPOSED CALCULATION VALUES
31 - D2.1 Amenities
31 - D2.2 Service pillars
32 - D3 DETERMINATION OF CALCULATED MAXIMUM DEMAND

Sets out requirements for electrical installations associated with pleasure craft intended to be supplied at low-voltage. Includes requirements for the internal electrical installation on board applicable pleasure craft and for electrical installations in marinas intended to supply electrical power to those craft. Does not apply to on-board generation on pleasure craft.

This Standard sets out requirements for electrical installations associated with pleasure craft intended for connection to low-voltage a.c. supply systems (i.e. exceeding 50 V a.c. but notexceeding 1 000 V a.c.).It includes requirements for the internal electrical installation on board applicable pleasure craft and for electrical installations in marinas intended to supply electrical power to those craft.NOTE: This Standard does not require specific instruction notices to be provided either on apleasure craft or on a marina. However, it is recommended that the marina operator provide eachpleasure craft operator intending to connect a pleasure craft to the marina low-voltage electrical supply with a copy of an instruction notice containing at least the information set out in Appendix A or Appendix B as appropriate.

Committee
EL-001
DocumentType
Standard
ISBN
0 7337 4501 6
Pages
26
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS 3004-1979.Second edition 1983.Third edition 1993.Jointly revised and designated as AS/NZS 3004:2002. First published as AS 3004-1979. Second edition 1983. Third edition 1993. Jointly revised and designated as AS/NZS 3004:2002.

AS/NZS 3120:1999 Approval and test specification - Cord extension sockets
AS/NZS 3109.1:1996 Approval and test specification - Appliance couplers for household and similar general purposes General requirements
AS/NZS 3112:2004 Approval and test specification - Plugs and socket-outlets
AS/NZS 3760:2003 In-service safety inspection and testing of electrical equipment
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures
AS/NZS 61009.1:2004 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD)
AS 2832.4-2006 Cathodic protection of metals Internal surfaces (Reconfirmed 2016)
AS 2832.2-2003 Cathodic protection of metals Compact buried structures
AS 2832.1-2004 Cathodic protection of metals Pipes and cables
AS 2832.5-2002 Cathodic protection of metals - Steel in concrete structures
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS/NZS 3108:1994 Approval and test specification - Particular requirements for isolating transformers and safety isolating transformers
AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
AS/NZS 3191:2003 Electric flexible cords

AS 1799.3-1985 Small pleasure boats code - Engineering
AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
AS/NZS 3760:2003 In-service safety inspection and testing of electrical equipment
AS/NZS 1768:2007 Lightning protection
AS/NZS 3019:2007 Electrical installations - Periodic verification
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 3962-2001 Guidelines for design of marinas
AS/NZS 1768(INT):2003 Lightning protection

View more information
US$69.34
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.