Telecommunications installations - Generic cabling systems - Specification for the testing of balanced communication cabling in accordance with values set out in AS/NZS 3080:2000

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Language(s)

English

Published date

12-20-2000

Preview

1 - AS/NZS 3087:2000 TELECOMMUNICATIONS INSTALLATIONS-GENERIC CABLING SYSTEMS-SPECIFICATION FOR THE TESTING OF BALANCED COMMUNICA
4 - PREFACE
6 - CONTENTS
10 - FOREWORD
12 - INTRODUCTION
13 - 1 Scope
13 - 2 Normative references
14 - 3 Definitions
14 - 3.1 cable assembly
14 - 3.2 attenuation (insertion loss, composite loss, operational attenuation and S 21 )
14 - 3.3 reflection coefficient
15 - 3.4 return loss
15 - 3.5 electrical length
15 - 3.6 propagation delay
15 - 3.7 minimum static bending radius
15 - 3.8 dynamic bending radius
15 - 3.9 screening attenuation (of the cable assembly)
15 - 3.10 coupling attenuation
16 - 3.11 unbalance attenuation
16 - 3.12 near-end cross-talk (NEXT)
16 - 3.13 far-end cross-talk (FEXT)
16 - 3.14 equal level far-end cross-talk (ELFEXT)
16 - 3.15 comparative test
16 - 3.16 nominal impedance
16 - 3.17 reference plane
16 - 3.18 power sum (NEXT & FEXT & ELFEXT)
16 - 3.19 delay skew
16 - 3.20 output signal balance (OSB)
16 - 3.21 d.c. loop resistance
17 - 4 Reference measurement procedures for electrical properties
17 - 4.1 Introduction
17 - 4.2 Test equipment considerations
17 - 4.2.1 Network analyzer test requirements
17 - 4.2.2 Termination of conductor pairs
18 - 4.2.3 Reference loads for calibration
18 - 4.2.4 Test configurations
19 - 4.2.5 Coaxial cables and test leads for network analyzers
20 - 4.2.6 Balun requirements
21 - 4.2.7 Network analyzer measurement precautions
21 - 4.2.8 Data reporting and accuracy
22 - 4.3 DC loop resistance
22 - 4.3.1 Object
22 - 4.3.2 Test method
22 - 4.3.3 Test equipment and set-up
22 - 4.3.4 Procedure
23 - 4.3.5 Test report
23 - 4.3.6 Uncertainty
23 - 4.4 Attenuation
23 - 4.4.1 Object
23 - 4.4.2 Test method
23 - 4.4.3 Test equipment and set-up
24 - 4.4.4 Procedure
24 - 4.4.5 Test report
24 - 4.4.6 Temperature correction
24 - 4.4.7 Uncertainty
24 - 4.5 Propagation delay and delay skew
24 - 4.5.1 Object
25 - 4.5.2 Test method
25 - 4.5.3 Test equipment and set-up
25 - 4.5.4 Procedure
26 - 4.5.5 Test report
26 - 4.5.6 Uncertainty of propagation delay and delay skew measurements
26 - 4.6 Near-end cross-talk (NEXT) pair-to-pair and power sum
26 - 4.6.1 Object
26 - 4.6.2 Test method
26 - 4.6.3 Test equipment and set-up
27 - 4.6.4 Procedure
27 - 4.6.5 Test report
28 - 4.6.6 Uncertainty of NEXT measurements
28 - 4.7 Far-end cross-talk (FEXT) pair-to-pair and power sum
28 - 4.7.1 Object
28 - 4.7.2 Test method
28 - 4.7.3 Test equipment and set-up
29 - 4.7.4 Procedure
29 - 4.7.5 Test report
29 - 4.7.6 Uncertainty of FEXT measurements
29 - 4.8 Equal level far-end cross-talk (ELFEXT)
29 - 4.8.1 Object
30 - 4.8.2 Calculation
30 - 4.8.3 Test report
30 - 4.8.4 Uncertainty of ELFEXT measurements
30 - 4.9 Return loss
30 - 4.9.1 Object
30 - 4.9.2 Test method
30 - 4.9.3 Test equipment and set-up
31 - 4.9.4 Procedure
31 - 4.9.5 Test report
31 - 4.9.6 Uncertainty of return loss measurements
31 - 4.10 Unbalance attenuation
32 - 4.11 Coupling attenuation
32 - 5 Field test measurement requirements for electrical properties
32 - 5.1 Introduction
32 - 5.2 Cabling configurations tested
32 - 5.3 Field test parameters
32 - 5.3.1 General
33 - 5.3.2 Inspection of workmanship and connectivity testing
34 - 5.3.3 Propagation delay and delay skew
34 - 5.3.4 Length
35 - 5.3.5 Attenuation
35 - 5.3.6 Pair-to-pair NEXT loss, power sum NEXT loss
36 - 5.3.7 Pair-to-pair ELFEXT loss, power sum ELFEXT loss
36 - 5.3.8 Return loss
36 - 5.3.9 DC loop resistance
36 - 5.4 Data reporting and accuracy
36 - 5.4.1 General
37 - 5.4.2 Detailed results
38 - 5.4.3 Summary results
41 - 5.5 Field measurement procedures
41 - 5.5.1 General
41 - 5.5.2 Consistency checks for field testers
41 - 5.5.3 Repeatability of tests on a reference link
41 - 5.5.4 Repeatability of tests by testing the same link in opposite directions
41 - 5.5.5 Administration
42 - 5.5.6 Test equipment connectors and cords
42 - 5.5.7 User cords
42 - 6 Field tester measurement accuracy requirements
42 - 6.1 General
43 - 6.2 Measurement accuracy specification for level IIE field testers
46 - 6.2.1 Field test equipment requirements for propagation delay
46 - 6.2.2 Field test equipment requirements for delay skew
46 - 6.2.3 Field test equipment requirements for length
46 - 6.2.4 Field test equipment requirements for loop d.c. resistance
46 - 6.3 Procedures for determining field tester parameters
46 - 6.3.1 General
47 - 6.3.2 Output signal balance (OSB)
47 - 6.3.3 Common mode rejection (CMR)
48 - 6.3.4 Residual NEXT loss
48 - 6.3.5 Dynamic accuracy
49 - 6.3.6 Source/load return loss
49 - 6.3.7 Random noise floor
49 - 6.3.8 Residual FEXT loss
50 - 6.3.9 Directivity
50 - 6.3.10 Tracking
51 - 6.3.11 Source match
51 - 6.3.12 Return loss of remote termination
51 - 6.3.13 Constant error term of the propagation delay measurement function
51 - 6.3.14 Error constant proportional to propagation delay of the propagation delay measurement function
52 - 6.3.15 Constant error term of the delay skew measurement function
52 - 6.3.16 Constant error term of the length measurement function
52 - 6.3.17 Error constant proportional to length of the length measurement function
52 - 6.3.18 Constant error term of the d.c. resistance measurement function
52 - 6.3.19 Error constant proportional to d.c. resistance of the d.c. resistance measurement function
52 - 6.3.20 Procedure to verify test cable performance
52 - 6.3.21 Procedure to verify test adapter performance
53 - 6.4 Measurement error models
53 - 6.4.1 General
53 - 6.4.2 Error model for the attenuation measurement function of level IIE field test equipment
53 - 6.4.3 Error model for the pair-to-pair NEXT loss measurement function of level IIE field test equipment
54 - 6.4.4 Error model for the power sum NEXT loss measurement function of level IIE field test equipment
54 - 6.4.5 Error model for the pair-to-pair ELFEXT loss measurement function of level IIE field test equipment
55 - 6.4.6 Error model for the power sum ELFEXT loss measurement function of level IIE field test equipment
55 - 6.4.7 Error model for the return loss measurement function of level IIE field test equipment
56 - 6.4.8 Error model for the propagation delay measurement function of level IIE field test equipment
57 - 6.4.9 (ex6.4.1.8) Error model for the delay skew measurement function of level IIE field test equipment
57 - 6.4.10 Error model for the length measurement function of level IIE field test equipment
57 - 6.4.11 Error model for the d.c. loop resistance measurement function of level IIE field test equipment
57 - 6.5 Network analyzer measurement comparisons
57 - 6.5.1 General
57 - 6.5.2 Adapters
59 - 6.5.3 Comparison methods

Specifies the reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in AS/NZS 3080. This Standard is an adoption of IEC 61935-1:2000.

This part of IEC 61935 specifies reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in ISO/IEC 11801. References in this Standard to ISO/IEC 11801 mean ISO/IEC 11801 or equivalent cabling Standards. This Standard applies when the cable assemblies are constructed of cables complying with IEC 61156-1, IEC 61156-2, IEC 61156-3 or IEC 61156-4, and of connecting hardware as specified in IEC 60603-7 or IEC 60807-8. In the case where cables and/or connectors do not comply with these standards, then additional tests may be required. This Standard relates to performance with respect to 100 ohms, 120 ohms or 150 ohms cabling.

Committee
CT-001
DocumentType
Standard
ISBN
0 7337 3723 4
Pages
49
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 61935-1:2000 Identical

Under Revision see DR 03102 CP. Under Revision see DR 03366 CP First published as AS/NZS 3087:2000.

AS/NZS 3080:1996 Telecommunications installations - Integrated telecommunications cabling systems for commercial premises

HB 29-2000 Communications Cabling Manual, Module 2: Communications Cabling Handbook

View more information
US$118.31
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.