• There are no items in your cart

AS/NZS 4782.3(INT):2006

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Double-capped fluorescent lamps - Performance specifications Procedure for quantitative analysis of mercury present in fluorescent lamps
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

07-16-2019

Language(s)

English

Published date

06-05-2006

Preview

1 - AS/NZS 4782.3(Int):2006 DOUBLE-CAPPED FLUORESCENT LAMPS-PERFORMANCE SPECIFICATIONS - PROCEDURE FOR QUANTITATIVE ANALYSIS...
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 EXCLUSIONS
7 - 1.3 APPLICATION
7 - 1.4 REFERENCED DOCUMENTS
8 - 1.5 DEFINITIONS
8 - 1.5.1 Aqua regia
8 - 1.5.2 Discharge electrodes
8 - 1.5.3 Double-capped fluorescent lamp
8 - 1.5.4 Fluorescent lamp
8 - 1.5.5 ICP-OES
8 - 1.5.6 Lamp samples
8 - 1.5.7 Measurement equipment
8 - 1.5.8 Primary check test
9 - 1.5.9 Secondary check test
9 - 1.5.10 Single-capped fluorescent lamp
9 - 2 TEST CONDITIONS
9 - 2.1 General
10 - 2.2 Measurement equipment
10 - 2.2.1 Preparation equipment required (dependent on the method employed)
10 - 2.2.2 Reagents-Standard procedure
10 - 2.2.3 Equipment for amalgam procedures
11 - 2.2.4 Instrument
11 - 3 TEST SET-UP
11 - 3.1 Lamps
12 - 3.2 Laboratory conditions
12 - 3.3 Sample set-up
12 - 3.3.1 Lamps
12 - 3.3.2 Containers
12 - 3.3.3 Acids
12 - 3.3.4 Standard solutions
12 - 3.3.5 Preparation equipment
12 - 3.4 Measuring equipment set-up
13 - 4 PROCEDURES
13 - 4.1 General
13 - 4.2 Test methods
13 - 4.2.1 Mercury decomposition in a lamp bulb not containing amalgams without breaking up the lamp (long linear lamp types).
14 - 4.2.2 Mercury composition in a fluorescent light bulb after destruction of the bulb
15 - 4.3 Decomposition of mercury amalgams
15 - 4.3.1 Titanium amalgam
16 - 4.3.2 Amalgam pellet and amalgam mesh
16 - 4.4 Samples for measurement
17 - 5 MEASUREMENT
17 - 5.1 Inductively coupled plasma-optical emission spectrophotometry
17 - 5.1.1 Abstract
17 - 5.1.2 Instrument
17 - 5.1.3 Setting of measuring conditions
17 - 5.1.4 Quantitative analysis from the ICP-OES
18 - 6 REPORTING
18 - 6.1 Recording
19 - 6.2 Measurement uncertainty
20 - APPENDIX A - BIBLIOGRAPHY

Specifies test method procedure to determine the mercury content in fluorescent lamps.

This part of the Standard outlines a procedure for quantitative analysis of mercury present in fluorescent lamps that are used in general lighting service and which are covered within the scope of AS/NZS 4782.1 and AS/NZS 60901. The testing method specifies the procedures that can be used to determine accurately the mercury content in a fluorescent lamp in which mercury is introduced as the medium for discharge between the electrodes. The method involves the chemical digestion of the mercury contained within a lamp and the determination of that mercury content on a per unit basis. This is achieved using a method of solubilization of the entire mercury content contained within the tube using acidic digestion methods and the accurate determination of that mercury content using standard mercury solutions. This will allow comparisons between lamps in batches and comparisons with other internationally accepted standards for mercury content in fluorescent lamps. This Interim Standard covers methods of determination of mercury by wet chemical analysis.

CommentClosesDate
06-05-2008
Committee
EL-041
DocumentType
Standard
ISBN
0 7337 7469 5
Pages
14
PublisherName
Standards Australia
Status
Superseded
SupersededBy

First published as AS/NZS 4782.3(Int):2006.

AS/NZS 60901:2003 Single-capped fluorescent lamps - Performance specifications
AS/NZS 2245:1999 Laboratory glassware - Filter funnels
AS 2165-1996 Laboratory glassware - Burettes
AS 2243.6-1990 Safety in laboratories - Mechanical aspects
AS 2166-2002 Laboratory glassware - One-mark pipettes
AS/NZS 2243.10:2004 Safety in laboratories Storage of chemicals
AS 2234-2002 Laboratory glassware - Beakers
AS/NZS 2243.3:2002 Safety in laboratories Microbiological aspects and containment facilities
AS 2243.7-1991 Safety in laboratories - Electrical aspects
AS/NZS 4782.1:2004 Double-capped fluorescent lamps - Performance specifications General (IEC 60081:2000, MOD) (Reconfirmed 2016)
AS 2164-2003 Laboratory glassware - One-mark volumetric flasks
AS/NZS 2243.8:2006 Safety in laboratories - Fume cupboards
AS/NZS 2243.5:2004 Safety in laboratories Non-ionizing radiations - Electromagnetic, sound and ultrasound
AS 2830.1-1985 Good laboratory practice - Chemical analysis
AS/NZS 2243.2:1997 Safety in laboratories - Chemical aspects
AS/NZS 4782.2:2004 Double-capped fluorescent lamps - Performance specifications Minimum Energy Performance Standard (MEPS) (Reconfirmed 2016)
AS/NZS 2243.1:2005 Safety in laboratories Planning and operational aspects

AS/NZS 4847.2(INT):2008 Self-ballasted lamps for general lighting services Minimum Energy Performance Standards (MEPS) requirements
AS/NZS 4847.1(INT):2008 Self-ballasted lamps for general lighting services Test methods - Energy performance
AS/NZS 4847.1:2010 Selfballasted lamps for general lighting services Test methods - Energy performance (Reconfirmed 2020)

View more information