• There are no items in your cart

AS/NZS 60079.17:2009

AvailableSuperseded
AvailableSuperseded

An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by Intertek Inform as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.

Explosive atmospheres Electrical installations inspection and maintenance (IEC 60079-17, Ed.4.0 (2007) MOD)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

09-18-2009

Preview

Adopts IEC 60079-17 Ed.4.0 with national modifications to cover factors directly related to inspection and maintenance of electrical installations within hazardous areas where the hazard may be caused by flammable gases, vapours, mists, dusts, fibres or flyings.

Committee
EL-014
DocumentType
Standard
ISBN
0 7337 9243 X
Pages
37
PublisherName
Standards Australia
Status
AvailableSuperseded
SupersededBy
Supersedes
UnderRevision

First published as AS/NZS 60079.17:2009.

AS/NZS 60079.26:2007 Explosive atmospheres Equipment with equipment protection level (EPL) Ga
AS/NZS 60079.20:2000 Electrical apparatus for explosive gas atmospheres Data for flammable gases and vapours, relating to the use of electrical apparatus
AS/NZS 4360:2004 Risk management
AS/NZS 60079.14:2009 Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD)
AS/NZS 61241.10:2005 Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present
AS/NZS 60079.15:2006 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection, n electrical apparatus
AS/NZS 60079.2:2007 Explosive atmospheres Equipment protection by pressurized enclosure 'p'
AS 2380.4-1994 Electrical equipment for explosive atmospheres - Explosion-protection techniques Pressurized rooms or pressurized enclosures (Reconfirmed 2013)
AS/NZS 60079.7:2006 Explosive atmospheres Equipment protection by increased safety 'e'
AS/NZS 61241.4:2002 Electrical apparatus for use in the presence of combustible dust Type of protection 'pD'
AS/NZS 60079.27:2008 Explosive atmospheres Fieldbus intrinsically safe concept (FISCO)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 61241.1:2005 Electrical apparatus for use in the presence of combustible dust Protection by enclosures 'tD'
AS/NZS 60079.29.2:2008 Explosive atmospheres Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
AS/NZS 60079.25:2004 Electrical apparatus for explosive gas atmospheres Intrinsically safe systems
AS/NZS 60079.28:2007 Explosive atmospheres Protection of equipment and transmission systems using optical radiation
AS/NZS 61241.11:2006 Electrical apparatus for use in the presence of combustible dust Protection by intrinsic safety iD
AS/NZS 61241.14:2005 Electrical apparatus for use in the presence of combustible dust Selection and installation (IEC 61241-14, Ed.1.0(2004) MOD)
AS/NZS 60079.10.1:2009 Explosive atmospheres Classification of areas - Explosive gas atmospheres (IEC 60079-10-1, Ed.1.0(2008) MOD)
AS/NZS 4761.2:2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Guide to assessing competency
AS/NZS 4761.1:2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Competency Standards
AS/NZS 60079.1:2007 Explosive atmospheres Equipment protection by flameproof enclosures 'd'
AS/NZS 60079.11:2006 Explosive atmospheres Equipment protection by intrinsic safety 'i'
AS/NZS 60079.0:2008 Explosive atmospheres Equipment - General requirements
AS/NZS 3800:2005 Electrical equipment for explosive atmospheres - Repair and overhaul
AS 1482-1985 Electrical equipment for explosive atmospheres - Protection by ventilation - Type of protection v (Reconfirmed 2013)
AS/NZS 60079.29.1:2008 Explosive atmospheres Gas detectors - Performance requirements of detectors for flammable gases

AS 4647-2011 Diaphragm gas meters
AS/NZS 1716:2012 Respiratory protective devices
AS/NZS 3010:2017 Electrical installations - Generating sets
AS/NZS 4836:2011 Safe working on or near low-voltage electrical installations and equipment
AS/NZS 60079.33:2012 Explosive atmospheres Equipment protection by special protection 's'
AS/NZS 2081:2011 Electrical protection devices for mines and quarries (Reconfirmed 2022)
AS/NZS 4745:2012 Code of practice for handling combustible dusts
HB 239:2011 Guidance on the repair and overhaul of electrical equipment for explosive atmospheres
AS 5092-2009 CNG refuelling stations
AS/NZS 5026:2012 The storage and handling of Class 4 dangerous goods
AS/NZS 1680.2.4:2017 Interior and workplace lighting Industrial tasks and processes
AS/NZS 60079.15:2011 Explosive atmospheres Equipment protection by type of protection 'n'
AS ISO 21789:2014 Gas turbine applications - Safety
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant

View more information
US$98.41
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.