AS/NZS 60898.1:2004

Current
Current

The latest, up-to-date edition.

Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. operation (IEC 60898-1, Ed. 1.2 (2003) MOD)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

08-13-2004

Preview

Proposes the adoption of IEC 60898-1:2003 as a revision of AS/NZS 4898:1997. Contains essential safety and associated requirements for a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125A and a rated short-circuit capacity not exceeding 25,000 A. Annex ZZ lists variations for Australian and New Zealand conditions.

This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. As far as possible, it is in line with the requirements contained in IEC 60947-2. These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained. They are intended for use in an environment with pollution degree 2. They are suitable for isolation. Circuit-breakers of this standard, with exception of those rated 120 V or 120/240 V (see table 1), are suitable for use in IT systems provided that the requirements of IEC 60364-4-473:1977 + A1:1998 are complied with. This standard also applies to circuit-breakers having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool. This standard does not apply to – circuit-breakers intended to protect motors; – circuit-breakers, the current setting of which is adjustable by means accessible to the user. For circuit-breakers having a degree of protection higher than IP20 according to IEC 60529, for use in locations where arduous environmental conditions prevail (e.g. excessive humidity, heat or cold or deposition of dust) and in hazardous locations (e.g. where explosions are liable to occur), special constructions may be required. Requirements for circuit-breakers for a.c. and d.c. operation are given in IEC 60898-2. Requirements for circuit-breakers which incorporate residual current tripping devices are to be found in IEC 61009-1, IEC 61009-2-1, and IEC 61009-2-2. A guide for co-ordination under short-circuit conditions between a circuit-breaker and another short-circuit protective device (SCPDs) is given in annex D. NOTE 1 For more severe overvoltage conditions, circuit-breakers complying with other standards (e.g. IEC 60947-2) should be used. NOTE 2 For an environment with a higher pollution degree, enclosures giving the appropriate degree of protection should be used. NOTE 3 Circuit-breakers within the scope of this standard may also be used for protection against electric shock in case of fault, depending on their tripping characteristics and on the characteristics of the installation. The criterion of application for such purposes is dealt with by installation rules. This standard contains all requirements necessary to ensure compliance with the operational characteristics required for these devices by type tests. It also contains the details relative to test requirements and methods of testing necessary to ensure reproducibility of test results. This standard states a) the characteristics of circuit-breakers; b) the conditions with which circuit-breakers shall comply, with reference to: 1) their operation and behaviour in normal service; 2) their operation and behaviour in case of overload; 3) their operation and behaviour in case of short-circuits up to their rated short-circuit capacity; 4) their dielectric properties; c) the tests intended for confirming that these conditions have been met and the methods to be adopted for the tests; d) the data to be marked on the devices; e) the test sequences to be carried out and the number of samples to be submitted for certification purposes (see annex C); f) the co-ordination under short-circuit conditions with another short-circuit protective device (SCPD) associated in the same circuit (see annex D); g) the routine tests to be carried out on each circuit-breaker to reveal unacceptable variations in material or manufacture, likely to affect safety (see annex I).

Committee
EL-004
DocumentType
Standard
ISBN
0 7337 3575 4
Pages
125
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
Supersedes

First published as AS/NZS 4898:1997.Jointly revised and redesignated as AS/NZS 60898.1:2004. First published as AS/NZS 4898:1997. Jointly revised and redesignated as AS/NZS 60898.1:2004.

AS 60038-2000 Standard voltages
AS/NZS 60695.2.10:2001 Glowing/hot wire based test methods Glow-wire apparatus and common test procedure
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 60269.3.1:2002 Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses
AS 60529-2004 Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018)
AS/NZS 60269.1:2000 Low-voltage fuses General requirements
AS/NZS 60269.2.0:2000 Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application)
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
HB 18.2:2003 Guidelines for third-party certification and accreditation Standardization and related activities - General vocabulary
AS 1852.441-1985 International electrotechnical vocabulary - Switchgear, controlgear and fuses
AS/NZS 60269.3.0:2000 Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications)
AS/NZS 60269.4.0:2000 Low-voltage fuses Supplementary requirements for fuse-links for the protection of semiconductor devices
AS/NZS 60269.2.1:2001 Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to V: Examples of types of standardized fuses
AS 1104-1978 Informative symbols for use on electrical and electronic equipment
AS/NZS 60112:2003
AS/NZS 5000.2:1999 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V

AS/NZS 3105:2007 Approval and test specification - Electrical portable outlet devices
AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS/NZS 3003:2018 Electrical installations - Patient areas
AS/NZS 3010:2017 Electrical installations - Generating sets
AS/NZS 3111:2009 Approval and test specification - Miniature overcurrent circuit-breakers (Reconfirmed 2020)
AS/NZS 3105:2012 Approval and test specification - Electrical portable outlet devices
AS/NZS 3197:2005 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 3017:2007 Electrical installations - Verification guidelines
AS/NZS 3003:2011 Electrical installations - Patient areas
AS/NZS 3190:2009 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 3105:2014 Approval and test specification - Electrical portable outlet devices
AS/NZS 61009.1:2004 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD)
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 4703:2007 Electrical wiring in furniture (Reconfirmed 2018)
AS/NZS 61009.1:2011 Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 3.0 (2010) MOD)
AS/NZS 3190:2016 Approval and test specification - Residual current devices (current operated earth-leakage devices)
AS/NZS 4763(INT):2006 Safety of Portable Inverters
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3190:2011 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS 60947.2-2005 Low-voltage switchgear and controlgear - Circuit-breakers

View more information
US$164.38
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.