1 - AS/NZS 60928:2000 AUXILIARIES FOR LAMPS-A.C. SUPPLIED ELECTRONIC BALLASTS FOR TUBULAR FLUORESCENT LAMPS-GENERAL AND SAFETY...
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
7 - SECTION 1: GENERAL REQUIREMENTS
7 - 1 Scope
7 - 2 Normative references
9 - 3 Definitions
9 - 3.1 ballast
9 - 3.1.1 independent ballast
9 - 3.1.2 built-in ballast
9 - 3.1.3 integral ballast
9 - 3.1.4 A.C. supplied electronic ballast
9 - 3.1.5 controllable ballasts
9 - 3.1.6 maximum value of lamp power (of a controllable ballast)
10 - 3.1.7 minimum value of lamp power (of a controllable ballast)
10 - 3.1.8 a.c./d.c. supplied electronic ballast for maintained emergency lighting
10 - 3.2 supply voltage
10 - 3.3 working voltage
10 - 3.4 maximum allowed peak voltage
10 - 3.5 supply current
10 - 3.6 live part
10 - 3.7 rectifying effect
10 - 3.8 type test
10 - 3.9 type-test sample
11 - 3.10 rated maximum operating temperature of a ballast case.
11 - 3.11 control terminals
11 - 3.12 control signal
11 - 3.13 cathode dummy resistor
11 - 4 General requirements
11 - 5 General notes on tests
12 - 6 Classification
12 - 7 Marking
12 - 7.1 Mandatory markings
13 - 7.2 Information to be provided, if applicable
13 - 7.3 Marking shall be durable and legible
13 - SECTION 2: SAFETY REQUIREMENTS
13 - 8 Terminals and cords
13 - 8.1 Terminals
14 - 8.2 Flexible cords
14 - 9 Provision for earthing
14 - 9.1 Protective earth (ground).
15 - 9.2 Functional earth (ground).
15 - 9.3 Frame or chassis.
15 - 10 Creepage distances and clearances
16 - 11 Protection against accidental contact with live parts
16 - 12 Protection of associated components
17 - 13 Moisture resistance and insulation
18 - 14 Electric strength
18 - 15 Abnormal conditions
19 - 16 Fault conditions
20 - 16.1 Short circuit across creepage distances and clearances if they are less than the values specified in clause 10, .....
20 - 16.2 Short circuit across or, if applicable, interruption of semi-conductor devices
20 - 16.3 Short circuit across insulation consisting of covering of lacquer, enamel or textile
20 - 16.4 Short circuit across electrolytic capacitors
20 - 16.5
21 - 17 Screws, current-carrying parts and connections
21 - 18 Resistance to heat and fire
22 - 19 Resistance to corrosion
26 - Annex A - Test to establish whether a conductive part is a live part which may cause an electric shock
27 - Annex B - Particular requirements for electronic ballasts with means of protection against overheating
27 - B.1 Scope
27 - B.2 Definition
27 - B.3 General requirements
27 - B.4 General notes on tests
27 - B.5 Classification
28 - B.6 Marking
28 - B.7 Limitation of heating
30 - Annex C - Particular additional safety requirements for a.c./d.c. supplied electronic ballasts for maintained emergency light
30 - C.1 Scope
30 - C.2 The definifions in clause 2 apply together with the following:
32 - C.3 Marking
32 - C.4 General statement
32 - C.5 Starting conditions
32 - C.6 Operating conditions
32 - C.7 Supply current
32 - C.8 Maximum current in any lead to a cathode
32 - C.9 Lamp operation current waveform
33 - C.10 Mains transient overvoltages
33 - C.11 Pulse voltage from central battery systems
33 - C.12 Tests for abnormal conditions
33 - C.13 Temperature cycling test and endurance test
34 - Annex D - Measurement of high-frequency leakage cuurent
35 - Annex ZZ - Variations to IEC 60928 for application in Australia and New Zealand
35 - ZZ1 Introduction
35 - ZZ2 Variations