• There are no items in your cart

AS/NZS 61000.6.2:2002

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electromagnetic compatibility (EMC) Generic standards - Immunity for industrial environments
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Language(s)

English

Published date

04-16-2002

1 - AS/NZS 61000.6.2:2002 ELECTROMAGNETIC COMPATIBILITY (EMC) - GENERIC STANDARDS-IMMUNITY FOR INDUSTRIAL ENVIRONMENTS
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
7 - 1 Scope and object
8 - 2 Normative references
9 - 3 Definitions
9 - 3.1 port
9 - 3.2 enclosure port
9 - 3.3 cable port
10 - 3.4 functional earth port
10 - 3.5 signal port
10 - 3.6 power port
10 - 4 Performance criteria
10 - 4.1 Performance criterion A
10 - 4.2 Performance criterion B
10 - 4.3 Performance criterion C
10 - 5 Conditions during testing
11 - 6 Product documentation
11 - 7 Applicability
11 - 8 Immunity test requirements
12 - Table 1 – Immunity – Enclosure ports
13 - Table 2 – Immunity – Signal ports
14 - Table 3 – Immunity – Input and output d. c. power ports
15 - Table 4 – Immunity – Input and output a. c. power ports
16 - Table 5 – Immunity – Functional earth ports

Sets out the EMC immunity requirements which apply to the electrical and electronic apparatus intended for use in industrial environments.

This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in industrial environments, as described below, for which no dedicated product or product-family immunity standard exists.Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified.Where a relevant dedicated product or product-family EMC immunity standard exists, it will take precedence over all aspects of this generic standard.The environments encompassed by this standard are industrial, both indoor and outdoor. Apparatus covered by this standard is intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below.Apparatus intended to be used in industrial locations are characterized by the existence of one or more of the following: a power network exists powered by a high or medium voltage power transformer dedicated for the supply of an installation feeding manufacturing or similar plant; industrial, scientific and medical (ISM)1) apparatus; heavy inductive or capacitive loads are frequently switched; currents and associated magnetic fields are high.The object of this standard is to define immunity test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances, including electrostatic discharges.The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard, but only those considered as relevant for the equipment covered by this standard.Test requirements are specified for each port considered.NOTE 1 Safety considerations are not covered by this standard.NOTE 2 In special cases, situations will arise where the level of disturbances may exceed the levels specified in this standard e.g. where an apparatus is installed in proximity to ISM equipment as defined in CISPR 11 or where a hand-held transmitter is used in close proximity to an apparatus. In these instances, special mitigation measures may have to be employed.NOTE 3 The industrial environment may be changed by special mitigation measures. Where such measures can be shown to produce an electromagnetic environment equivalent to the residential, commercial or light-industrial environment then the generic standard for this environment, or the relevant product standard, should be applied.

Committee
TE-003
DocumentType
Standard
ISBN
0 7337 4244 0
Pages
10
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 61000-6-2 : 1.0 Identical
IEC 61000-6-2:1999 Identical

First published as AS/NZS 61000.6.2:2002.

AS/NZS 61000.4.6:1999 Electromagnetic compatibility (EMC) Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
AS/NZS 2064:1997 Limits and methods of measurement of electromagnetic disturbance characteristics of industrial, scientific and medical (ISM) radiofrequency equipment
AS/NZS 61000.4.5:1999 Electromagnetic compatibility (EMC) Testing and measurement techniques - Surge immunity test
AS/NZS 61000.4.3:1999 Electromagnetic compatibility (EMC) Testing and measurement techniques - Radiated radio-frequency electromagnetic field immunity test
AS/NZS 3548:1995 Limits and methods of measurement of radio disturbance characteristics of information technology equipment

AS 1418.1-2002 Cranes, hoists and winches General requirements
AS 62061-2006 Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems

View more information
US$48.59
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.