• There are no items in your cart

AS/NZS IEC 60332.3.22:2017

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Tests on electric and optical fibre cables under fire conditions, Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

08-17-2023

Language(s)

English

Published date

06-30-2017

The objective of this Standard is to specify methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. This Standard specifies Category A and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 7 l/m of test sample. This category is intended for general use where high volumes of non-metallic material are required to be evaluated.

The series of International Standards covered by Parts 3-10, 3-21, 3-22, 3-23, 3-24 and 3-25 of IEC 60332 specifies methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.NOTE For the purpose of this standard the term "electric wire or cable" covers all insulated metallic conductor cables used for the conveyance of energy or signals.The test is intended for type approval testing. The requirements for the selection of cables for testing are given in annex A. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable’s ability to limit flame spread.This part of IEC 60332 covers category A and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 7 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the ladder, a standard or wide ladder being used for cables having a conductor cross-section greater than 35 mm² according to the number of test pieces required, and a standard ladder for conductor cross-sections 35 mm² and smaller. The category is intended for general use where high volumes of non-metallic material are required to be evaluated.A recommended performance requirement is given in annex B.

Committee
EL-003
DevelopmentNote
Under Revision by DR AS/NZS IEC 60332.3.22:2021.
DocumentType
Standard
ISBN
978 1 76035 829 7
Pages
9
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 60332-3-22:2000+AMD1:2008 CSV Identical

Originated in Australia as SAA Int 88001—1988.Jointly revised and designated as AS/NZS 1660.5.1:1998.Third edition 2005.AS/NZS 1660.5.1:2005 revised and redesignated, in part, as AS/NZS IEC 60332.3.22:2017. Originated in Australia as SAA Int 88001-1988. Jointly revised and designated as AS/NZS 1660.5.1:1998. Third edition 2005. AS/NZS 1660.5.1:2005 revised and redesignated, in part, as AS/NZS IEC 60332.3.22:2017.

View more information
US$48.74
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.