• There are no items in your cart

ASTM C 550 : 2015 : REDLINE

Current
Current

The latest, up-to-date edition.

Standard Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation
Available format(s)

PDF

Language(s)

English

Published date

10-15-2015

CONTAINED IN VOL. 04.06, 2016 Defines locations for measuring the trueness and squareness of rigid block/board thermal insulation.

1.1This test method covers locations for measuring the trueness and squareness of rigid block/board thermal insulation. This test method does not purport to address the variability in board thickness. Thickness is addressed in other ASTM standards.

1.2The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Committee
C 16
DocumentType
Redline
Pages
6
PublisherName
American Society for Testing and Materials
Status
Current

HH-I-1972-5 Base Document:1981 INSULATION BOARD, THERMAL, POLYURETHANE OR POLYISOCYANURATE FACED WITH PERLITE BOARD ON BOTH SIDES OF THE FOAM
HH-I-1972 Base Document:1981 INSULATION BOARD, THERMAL, FACED, POLYURETHANE OR POLYISOCYANURATE
HH-I-1972-3 Base Document:1981 INSULATION BOARD, THERMAL, POLYURETHANE OR POLYISOCYANURATE FACED WITH PERLITE INSULATION BOARD ON ONE SIDE AND ASPHALT/ORGANIC FELT OR ASPHALT/GLASS FIBER FELT ON THE OTHER SIDE OF THE FOAM
HH-I-1972-1 Base Document:1981 INSULATION BOARD, THERMAL, POLYURETHANE OR POLYISOCYANURATE, FACED WITH ALUMINUM FOIL ON BOTH SIDES OF THE FOAM
ASTM E 936 : 1998 : R2004 Standard Practice for Roof System Assemblies Employing Steel Deck, Preformed Roof Insulation, and Bituminous Built-Up Roofing (Withdrawn 2012)
HH-I-1972-2 Base Document:1981 INSULATION BOARD, THERMAL, POLYURETHANE OR POLYISOCYANURATE FACED WITH ASPHALT/ORGANIC FELT, ASPHALT/ASBESTOS FELT OR ASPHALT/GLASS FIBER FELT ON BOTH SIDES OF THE FOAM
HH-I-1972-4 Base Document:1981 INSULATION BOARD, THERMAL, POLYURETHANE OR POLYISOCYANURATE FACED WITH GYPSUM BOARD ON SIDE AND ALUMINUM FOIL OR ASPHALT/ORGANIC FELT ON THE OTHER SIDE OF THE FOAM
ASTM E 1730 : 2015 : REDLINE SPECIFICATION FOR RIGID FOAM FOR USE IN STRUCTURAL SANDWICH PANEL CORES
HH-I-1972-6 Base Document:1981 INSULATION BOARD, THERMAL, POLYURETHANE OR POLYISOCYANURATE FACED WITH MINERAL FIBERBOARD ON ONE SIDE OF THE FOAM AND GLASS MAT ON THE OTHER SIDE OF THE FOAM
ASTM C 1050 : 1991 Standard Specification for Rigid Cellular Polystyrene-Cellulosic Fiber Composite Roof Insulation (Withdrawn 1999)
ASTM E 936 : 1998 Standard Practice for Roof System Assemblies Employing Steel Deck, Preformed Roof Insulation, and Bituminous Built-Up Roofing
A123.25-18 Asphalt core boards used in roofing

ASTM E 177 : 2014 : REDLINE Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods
ASTM C 168 : 2017-06 TERMINOLOGY RELATING TO THERMAL INSULATION

View more information
US$66.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.