Standard Test Method for Determination of Water Vapor (Moisture Concentration) in Natural Gas by Tunable Diode Laser Spectroscopy (TDLAS)
Available format(s)

Hardcopy , PDF

Superseded date

11-10-2021

Language(s)

English

Published date

02-18-2015

CONTAINED IN VOL. 05.06, 2015 Defines online determination of vapor phase moisture concentration in natural gas using a tunable diode laser absorption spectroscopy (TDLAS) analyzer also known as a 'TDL analyzer.'

1.1This test method covers online determination of vapor phase moisture concentration in natural gas using a tunable diode laser absorption spectroscopy (TDLAS) analyzer also known as a “TDL analyzer.” The particular wavelength for moisture measurement varies by manufacturer; typically between 1000 and 10 000 nm with an individual laser having a tunable range of less than 10 nm.

1.2Process stream pressures can range from 700-mbar to 700-bar gage. TDLAS is performed at pressures near atmospheric (700- to 2000-mbar gage); therefore, pressure reduction is typically required. TDLAS can be performed in vacuum conditions with good results; however, the sample conditioning requirements are different because of higher complexity and a tendency for moisture ingress and are not covered by this test method. Generally speaking, the vent line of a TDL analyzer is tolerant to small pressure changes on the order of 50 to 200 mbar, but it is important to observe the manufacturer’s published inlet pressure and vent pressure constraints. Large spikes or steps in backpressure may affect the analyzer readings.

1.3The typical sample temperature range is -20 to 65°C in the analyzer cell. While sample system design is not covered by this standard, it is common practice to heat the sample transport line to around 50°C to avoid concentration changes associated with adsorption and desorption of moisture along the walls of the sample transport line.

1.4The moisture concentration range is 1 to 10 000 parts per million by volume (ppmv). It is unlikely that one spectrometer cell will be used to measure this entire range. For example, a TDL spectrometer may have a maximum measurement of 1 ppmv, 100 ppmv, 1000 ppmv, or 10 000 ppmv with varying degrees of accuracy and different lower detection limits.

1.5TDL absorption spectroscopy measures molar ratios such as ppmv or mole percentage. Volumetric ratios (ppmv and %) are not pressure dependant. Weight-per-volume units such as milligrams of water per standard cubic metre or pounds of water per standard cubic foot can be derived from ppmv at a specific condition such as standard temperature and pressure (STP). Standard conditions may be defined differently for different regions and entities. The moisture dew point can be estimated from ppmv and pressure. Refer to Test Method D1142 and ISO 18453.

1.6The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 8 on Hazards.

Committee
D 03
DocumentType
Test Method
Pages
7
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

ASTM D 8080 : 2021 Standard Specification for Compressed Natural Gas (CNG) and Liquefied Natural Gas (LNG) Used as a Motor Vehicle Fuel

ASTM D 1142 : 1995 : R2000 Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature
ASTM D 1142 : 1995 : R2021 Standard Test Method for Water Vapor Content of Gaseous Fuels by<brk/> Measurement of Dew-Point Temperature
ISO 10715:1997 Natural gas — Sampling guidelines
ASTM D 4150 : 2021 : REV A Standard Terminology Relating to Gaseous Fuels
ASTM D 4150 : 2020 : REV A Standard Terminology Relating to Gaseous Fuels
ASTM D 5454 : 1993 : R1999 Standard Test Method for Water Vapor Content of Gaseous Fuels Using Electronic Moisture Analyzers
ASTM D 5454 : 2004 Standard Test Method for Water Vapor Content of Gaseous Fuels Using Electronic Moisture Analyzers
ASTM D 1142 : 1995 : R2006 Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature
ASTM D 5454 : 2011 : R2020 Standard Test Method for Water Vapor Content of Gaseous Fuels Using Electronic Moisture Analyzers
ASTM D 5503 : 1994 : R2003 Standard Practice for Natural Gas Sample-Handling and Conditioning Systems for Pipeline Instrumentation
ASTM D 5454 : 2011 Standard Test Method for Water Vapor Content of Gaseous Fuels Using Electronic Moisture Analyzers
ASTM D 4150 : 2019 Standard Terminology Relating to Gaseous Fuels
ASTM D 4150 : 2008 Standard Terminology Relating to Gaseous Fuels
ASTM D 4150 : 2000 Standard Terminology Relating to Gaseous Fuels
ASTM D 5454 : 2011 : EDT 1 Standard Test Method for Water Vapor Content of Gaseous Fuels Using Electronic Moisture Analyzers
ASTM D 5503 : 1994 : R1999 Standard Practice for Natural Gas Sample-Handling and Conditioning Systems for Pipeline Instrumentation
ASTM D 1142 : 1995 Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature
ASTM D 4150 : 2003 Standard Terminology Relating to Gaseous Fuels
ASTM D 5503 : 1994 : R2008 Standard Practice for Natural Gas Sample-Handling and Conditioning Systems for Pipeline Instrumentation (Withdrawn 2017)
ASTM D 4150 : 2021 Standard Terminology Relating to Gaseous Fuels
ASTM D 4150 : 2008 : R2016 Standard Terminology Relating to Gaseous Fuels
ISO 18453:2004 Natural gas — Correlation between water content and water dew point
ASTM D 1142 : 1995 : R2012 Standard Test Method for Water Vapor Content of Gaseous Fuels by<brk/> Measurement of Dew-Point Temperature

View more information
US$75.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.