Photometric data for luminaires Photometric measurements
Available format(s)

Hardcopy , PDF

Superseded date

01-28-2005

Language(s)

English

Published date

08-15-1999

Co-operating organizations
Foreword
Section one. General
1. Scope
2. References
3. Definitions
4. Units and terminology
5. Photometric centre
6. Cut-off angle reference points (lamps)
7. Co-ordinate systems for luminaires
Section two. Laboratory conditions and procedure
8. General
9. Laboratory measurements
10. Laboratory facilities
11. Status of measurements
12. Electric power supply and indicating instruments
13. Temperature control and indicating instruments
14. Photocells and associated apparatus
15. Selection of luminaires for test
16. Selection of ballasts for use with luminaires under
      test
17. Selection of ballasts for bare lamp measurements
18. Selection and preparation of lamps for use with
      luminaires under test
19. Operation and handling of lamps
20. Standard measuring conditions for luminaires
21. Standard measuring conditions for bare lamps
22. Stabilization
23. Measuring procedures
24. Reporting of measurements
Section three. Goniophotometers
25. General
26. Purpose of goniophotometer
27. Construction
28. Optical path length
29. General requirements
30. Requirements for mirrors
31. Screening against stray light
32. Checking the goniophotometer
33. Selection of lamps, ballasts, luminaires
34. Mounting of the luminaire
35. Mounting of the bare lamp
36. Measuring conditions
37. Measurement of luminaire
38. Measurement of bare lamp
39. Reporting of measurements
Section four. Photometric integrators for luminaires
40. General
41. Purpose of photometric integrators
42. Construction
43. Reflecting surfaces
44. Components inside an integrator
45. Air temperature measurements
46. The test-patch
47. Photocells and associated apparatus
48. Direct light screen
49. Auxiliary lamp
50. Checking the integrator
51. Selection of lamps, ballasts, luminaires
52. Mounting the luminaire
53. Mounting the bare lamp
54. Measuring conditions
55. Measuring procedure for light output ratio (LOR)
56. Reporting of measurements
Section five. Photometric factors
57. General
58. Measurement correction factors
59. Service correction factors
60. Ballast lumen factor (BLF)
Section six. Luminance measurements
61. General
62. Types of luminance measurements
63. Measuring apparatus
64. Selection of lamps, ballasts, luminaires
65. Average luminance: measuring procedure
66. Patch luminance: measuring procedure
67. Patch Luminance: alternative measuring procedure
68. Reporting of luminance measurements
69. Determination of cut-off angle
Section seven. Illuminance measurements (single luminaire)
70. General
71. Measuring apparatus
72. Selection of lamps, ballasts, luminaires
73. Measuring procedure
74. Calibration of measurements
75. Reporting of measurements
Appendices
A. Light output ratio for luminaires
B. Calibration of measurements
C. Check of photocell linearity
D. Check of photocell spectral response
E. Standard mounting boards
F. Commissioning of goniophotometers
G. Selection of type of goniophotometer
H. Initial checking of integrators
J. Amalgam lamps
K. Correction calculation for lamps whose luminous flux
     is specified for temperatures other than 25 degrees C
Tables
1. Determination of LOR of a luminaire
2. Features of goniophotometer types
     Bibliography
Figures
1. Photometric centre of a luminaire
2. Co-ordinate system for luminaires
3. Types of goniophotometer
4. Alignment projector for goniophotometer
5. Photometric integrator: schematic layout
6. Projected width of luminaires: examples

Laboratory conditions, procedures and instrumentation for measurements on single general purpose luminaires and methods of measuring luminance and illuminance.

Committee
EL/1
DevelopmentNote
Supersedes 73/26052 DC, 98/202854 DC and BS 398(1948). (05/2005) Reviewed and confirmed by BSI, August 2006. (07/2006)
DocumentType
Standard
Pages
46
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 3224-1:1988 Lighting fittings for civil land aerodromes Specification for lighting units for use in precision approach path indicator systems
BS 4533-103.1(1981) : 1981 LUMINAIRES - PERFORMANCE REQUIREMENTS - SPECIFICATION FOR LIGHT DISTRIBUTION FROM ROAD-LIGHTING LANTERNS
BS 3143-1:1985 Road danger lamps Specification for kerosine burning lamps
BS 5489-2:1992 Road lighting Code of practice for lighting for traffic routes
BS 5489-2:1987 Road lighting Code of practice for lighting for traffic routes
BS 8206-1:1985 Lighting for buildings Code of practice for artificial lighting
BS 3143-4:1985 Road danger lamps Specification for high intensity battery operated beacons
BS 3224-6:1988 Lighting fittings for civil land aerodromes Specification for obstacle lighting units
BS 873-7:1984 Road traffic signs and internally illuminated bollards Specification for posts and fittings
BS 5489-5:1992 Road lighting Code of practice for lighting for grade-separated junctions
BS 873-2:1984 Road traffic signs and internally illuminated bollards Specification for miscellaneous signs
BS 5489-7:1990 Road lighting Code of practice for the lighting of tunnels and underpasses
BS 354:1995 Recommendations for photometric integrators
BS 5489-6:1992 Road lighting Code of practice for lighting for bridges and elevated roads
BS 5489-5:1989 Road lighting Code of practice for lighting for grade-separated junctions
BS 5489-3:1992 Road lighting Code of practice for lighting for subsidiary roads and associated pedestrian areas
BS 3143-2:1990 Road danger lamps Specification for low-intensity battery-operated lamps
BS 5489-9:1996 Road lighting Code of practice for lighting for urban centres and public amenity areas
BS 5489-7:1992 Road lighting Code of practice for the lighting of tunnels and underpasses
BS 5489-10:1992 Road lighting Code of practice for lighting for motorways
BS 873-1:1983 Road traffic signs and internally illuminated bollards Methods of test
BS 5489-9:1992 Road lighting Code of practice for lighting for urban centres and public amenity areas
BS 873-3:1980 Road traffic signs and internally illuminated bollards Specification for internally illuminated bollards
BS 5489-6:1990 Road lighting Code of practice for lighting for bridges and elevated roads
BS 5489-9:1990 Road lighting Code of practice for lighting for urban centres and public amenity areas
BS 5489-3:1989 Road lighting Code of practice for lighting for subsidiary roads and associated pedestrian areas
BS 5225-3:1982 Photometric data for luminaires Method of photometric measurement of battery-operated emergency lighting luminaires
BS 5489-10:1990 Road lighting Code of practice for lighting for motorways
BS 4533-103.2:1986 Luminaires. Performance requirements Specification for photometric characteristics of luminaires for hospitals and health care buildings
BS 5972:1980 Specification for photoelectric control units for road lighting
06/30036109 DC : DRAFT APR 2006 BS 8442 - MISCELLANEOUS ROAD TRAFFIC SIGNS AND DEVICES - REQUIREMENTS AND TEST METHODS

BS 667:2005 Illuminance meters. Requirements and test methods
BS 354:1995 Recommendations for photometric integrators
BS 4727-5:GRP01(1985) : 1985 GLOSSARY OF ELECTROTECHNICAL POWER TELECOMMUNICATION ELECTRONICS LIGHTING & COLOUR TERMS - TERMS PARTICULAR TO ELECTROMEDICAL EQUIPMENT RADIOLOGY & RADIOLOGICAL PHYSICS TERMINOLOGY
BS 2818-2:1985 Ballasts for tubular fluorescent lamps Specification for ballasts for use with lamps used in the UK not included in BS 1853 \'Tubular fluorescent lamps for general lighting service\' Part 1 \'Specification for internationally specified lamps\'
BS 3900-D2:1967 Methods of test for paints. Gloss (specular reflection value)
BS 1853-2:1995 Tubular fluorescent lamps for general lighting service Specification for lamps used in the United Kingdom not included in BS EN 60081, BS EN 60901, BS EN 61195 and BS EN 61199

View more information
US$277.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.