• There are no items in your cart

BS 6068-6.7:1994

Current
Current

The latest, up-to-date edition.

Water quality. Sampling Guidance on sampling of water and steam in boiler plants
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-15-1994

National foreword
Committees responsible
Method
1. Scope
2. Normative references
3. Definitions
4. Sampling - General aspects
5. Sampling equipment
6. Sampling locations
7. Collection of water samples
8. Collection of steam samples
9. Preservation of samples
10. Sample identification and records
Annexes
A. (informative) Sampling points in boiler plants
B. (informative) Coolers
C. (informative) Report - Sampling of water and steam
    in boiler plants
Tables
1. Recommended minimum mass flow through sampling probe
    for various steam pressures
A.1 Typical sample conditions at various sampling points
    in steam and water circuits
B.1 Operating parameters of a sample cooler
Figures
1. Schematic water sampling system
2. Example of a straight circular sampling probe for
    sampling soluble species
3. Example of a directional sampling probe for sampling
    particulates in water
4. Example of a water sampling probe for both soluble
    and particulate sampling
5. Examples of sampling probes for sampling saturated
    steam
6. Example of a steam sampling probe, multiport type
7. Radii of circles for dividing a circular pipe into
    annuli of equal areas
8. Typical capillary sampler arrangement
A.1 Location of principal sampling points
B.1 Example of a typical sample cooler

Recommends procedures and equipment for sampling water and steam in boiler plants. Does not apply to the sampling of water and steam in nuclear power plants. Includes definitions, tables and diagrams.

This part of ISO 5667 recommends procedures and equipment for sampling water and steam in boiler plants including examples of sampling apparatus, to provide samples for physical and chemical analysis that are representative of the main body of water or steam from which they are taken.

The procedures for sampling water apply to

  • raw water;
  • make-up water;
  • boiler feed water;
  • condensate;
  • boiler water;
  • cooling water.

The procedures for sampling steam cover both saturated and superheated steam.

This part of ISO 5667 does not apply to the sampling of water and steam in nuclear power plants.

Figure 2 to Figure 6 are only given as examples of sampling apparatus.

Committee
EH/3/6
DevelopmentNote
Also numbered as ISO 5667-7 Supersedes 91/55510 DC, BS 1328(1969) and BS 3285(1960) (09/2005)
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Current
Supersedes

12/30215289 DC : 0 BS 8552 - SAMPLING AND MONITORING OF WATER FROM BUILDING SERVICES CLOSED SYSTEMS - CODE OF PRACTICE
BS 6068-6.10:1993 Water quality. Sampling Guidance on sampling of waste waters
BS 2486:1997 Recommendations for treatment of water for steam boilers and water heaters
BS 1427:2009 Guide to on-site test methods for the analysis of waters
BS 8552:2012 Sampling and monitoring of water from building services closed systems. Code of practice

BS 6068-6.3(1986) : 1986 WATER QUALITY - SAMPLING - GUIDANCE ON THE PRESERVATION AND HANDLING OF SAMPLES
BS 6068-6.1(1981) : AMD 7435 WATER QUALITY - SAMPLING - GUIDANCE ON THE DESIGN OF SAMPLING PROGRAMMES
BS 6068-4.2:1989 Water quality. Microbiological methods Guide to the enumeration of micro-organism by culture
BS EN 25667-2:1993 Water quality. Sampling Guidance on sampling techniques

View more information
US$170.10
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.