BS EN 14791:2017

Current

Current

The latest, up-to-date edition.

Stationary source emissions. Determination of mass concentration of sulphur oxides. Standard reference method

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

03-31-2017

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Description of measuring system
7 Performance characteristics of the SRM
8 Field operation
9 Analytical procedure
10 Expression of results
11 Equivalence of Thorin and ion chromatography methods
12 Equivalence of an alternative method
13 Measurement report
Annex A (informative) - Validation of the method in the field
Annex B (informative) - Examples of absorbers
Annex C (informative) - Example of assessment of compliance of
        standard reference method for SO[2] with requirements on
        emission measurements
Annex D (informative) - Type of sampling equipment
Annex E (informative) - Example of comparison of repeatability and
        trueness of Thorin Method and Ion Chromatography Method
Annex F (informative) - Calculation of the uncertainty associated
        with a concentration expressed on dry gas and at an oxygen
        reference concentration
Annex G (informative) - Significant technical changes
Bibliography

Defines the standard reference method (SRM) for the determination of the sulphuric oxide SO[2] in flue gases emitted to the atmosphere from ducts and stacks.

This European Standard specifies the standard reference method (SRM) for the determination of the sulphuric oxide SO 2 in flue gases emitted to the atmosphere from ducts and stacks. It is based on a sampling system and two analytical principles: ion chromatography and the Thorin method. This European Standard specifies the performance characteristics to be determined and the performance criteria to be fulfilled by measuring systems based on the measurement method. It applies to periodic monitoring and to the calibration or control of automatic measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes. This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of EN14793:2017 . This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30min in the range of 0,5mg/m 3 to 2000mg/m 3 of SO 2 for an ion-chromatography variant and 5mg/m 3 to 2000mg/m 3 of SO 2 for the Thorin method according to emission limit values laid down in the Directive 2010/75/EU . NOTE1 Emission limit values for SO 2 laid down in the Directive 2010/75/EU are in the range of 30mg/m 3 to 800mg/m 3. The emission limit values of EU Directives are expressed in units of mg/m 3 of SO 2 on dry basis and at standard conditions of 273K and 101,3kPa. NOTE2 The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in AnnexA.

Committee
EH/2/1
DevelopmentNote
Supersedes 03/312902 DC. (02/2006) Supersedes 14/30293544 DC. (03/2017)
DocumentType
Standard
Pages
74
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
UNI EN 14791 : 2006 Identical
EN 14791:2017 Identical
DIN EN 14791:2006-04 Identical
NF EN 14791 : 2017 Identical
UNE-EN 14791:2006 Identical
NS EN 14791 : 2017 Identical
NEN EN 14791 : 2017 Identical
I.S. EN 14791:2017 Identical
SN EN 14791 : 2017 Identical
NBN EN 14791 : 2006 Identical
DIN EN 14791 E : 2006 Identical
UNE-EN 14791:2017 Identical

CEN/TS 15675:2007 Air quality - Measurement of stationary source emissions - Application of EN ISO/IEC 17025:2005 to periodic measurements
ISO 14956:2002 Air quality Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
PREN 13284-1 : DRAFT 2015 STATIONARY SOURCE EMISSIONS - DETERMINATION OF LOW RANGE MASS CONCENTRATION OF DUST - PART 1: MANUAL GRAVIMETRIC METHOD
EN ISO 14956 : 2002 AIR QUALITY - EVALUATION OF THE SUITABILITY OF A MEASUREMENT PROCEDURE BY COMPARISON WITH A REQUIRED MEASUREMENT UNCERTAINTY
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
EN 14793:2017 Stationary source emissions - Demonstration of equivalence of an alternative method with a reference method

View more information
US$335.40
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.