• There are no items in your cart

BS EN 14944-3:2007

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Influence of cementitious products on water intended for human consumption. Test methods Migration of substances from factory-made cementitious products
Superseded date

01-12-2024

Published date

01-31-2008

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and Definitions
4 Principle
5 Reagents
   5.1 General requirements
   5.2 Disinfection reagents
        5.2.1 Sodium hypochlorite solution
        5.2.2 Disinfection treatment water
   5.3 Waters to be used for testing
        5.3.1 Preconditioning water
        5.3.2 Test water
        5.3.3 Test water without chlorine content (chlorine-free)
        5.3.4 Test water with chlorine content (chlorinated)
   5.4 Cleaning liquids for apparatus
6 Apparatus
   6.1 General
   6.2 Apparatus and materials for test piece preparation
        6.2.1 Stainless steel plates and cylinders
        6.2.2 Glass cylinders
        6.2.3 Moulds for forming test pieces
   6.3 Apparatus and materials for preconditioning and migration
        procedure
        6.3.1 Vessels, containers, covers, connectors and stoppers
7 Samples and test pieces
   7.1 Sampling, transport and storage of samples
   7.2 Preparation of test pieces
        7.2.1 General
        7.2.2 Factory made pipes, fittings and storage systems
   7.3 Surface area-to-volume ratio (S/V) for use in the test
        procedure
        7.3.1 General
        7.3.2 Pipes and fittings
        7.3.3 Storage systems (cement mortar, cement mortar lined
              or concrete)
8 Pre-treatment of samples (curing, preconditioning and disinfection)
   8.1 General
   8.2 Curing
   8.3 Preconditioning
        8.3.1 General
        8.3.2 Preconditioning without disinfection treatment
        8.3.3 Preconditioning with disinfection treatment
9 Test procedure
   9.1 General
   9.2 Preparation of migration water for analysis of substances
        9.2.1 Migration procedure
        9.2.2 Second and third migration periods
        9.2.3 Additional migration periods
   9.3 Control samples (blank test)
10 Analysis
11 Calculation of test results
   11.1 Calculation of the concentration of the substances in the
        migration water
   11.2 Calculation of the migration rate of the measured substances
   11.3 Calculation of the mean migration rate
12 Test report
   12.1 General information
   12.2 Information on the product
   12.3 Information on the test procedure
   12.4 Test results
Annex A (normative) Additional procedures for testing factory made
        pipes (cement mortar lined and concrete)
      A.1 Sampling, test piece preparation and storage
          A.1.1 Sampling
          A.1.2 Test piece preparation and storage
      A.2 Surface area to volume (S/V) ratio
      A.3 Pretreatment of test pieces (preconditioning and
          disinfection)
      A.4 Test procedure
          A.4.1 Migration procedure at 23 degree C
          A.4.2 Migration procedure at elevated temperature
      A.5 Expression of results
      A.6 Reporting
Annex B (normative) Additional procedures for testing factory made
        fittings (cement mortar lined and concrete)
      B.1 Sampling, test piece preparation and storage
          B.1.1 Sampling of Factory made fittings
          B.1.2 Test piece preparation and storage
      B.2 Surface area to volume (S/V) ratio
      B.3 Pre-treatment of test pieces (preconditioning and
          disinfection)
      B.4 Test procedure
          B.4.1 Migration procedure at 23 degree C
          B.4.2 Migration procedure at elevated temperature
      B.5 Expression of results
      B.6 Reporting
Annex C (normative) Additional procedures for testing factory made
        storage systems (cement mortar, cement mortar lined and
        concrete)
      C.1 Sampling, test piece preparation and storage
          C.1.1 Sampling
          C.1.2 Test piece preparation and storage
      C.2 Surface area to volume (S/V) ratio
      C.3 Pretreatment of test pieces (preconditioning and
          disinfection)
      C.4 Test procedure
          C.4.1 Migration procedure at 23 degree C
          C.4.2 Migration procedure at elevated temperature
      C.5 Expression of results
      C.6 Reporting
Annex D (informative) Examples of typical test pieces and test
        conditions as a function of S/V ratio
      D.1 General
      D.2 Pipes and fittings
      D.3 Test pieces to which a cylinder of stainless steel or
          glass is to be attached
      D.4 Square test plates coated with mortar
      D.5 Moulded test pieces where all faces are exposed to test
          water
Annex E (informative) Test arrangements for testing factory made
        cementitious products
Annex F (normative) Additional procedures for testing factory made
        cementitious products at elevated temperature
      F.1 General
      F.2 Test procedure at elevated temperature
          F.2.1 General
          F.2.2 Preparation of migration water for the assessment
                of migration of substances
      F.3 Control samples (blank test)
      F.4 Expression of results
      F.5 Reporting
Annex G (informative) Discrimination between porous and non-porous
        coatings on factory made products
      G.1 Principle
      G.2 Apparatus
          G.2.1 stainless steel plates
          G.2.2 cylinders
          G.2.3 pH meter
      G.3 Materials and reagents
          G.3.1 sealing compound/sealant
          G.3.2 demineralized water
      G.4 Test procedure
          G.4.1 General
          G.4.2 Laboratory blank
          G.4.3 Coated product
      G.5 Determination of pH
      G.6 Expression of results
      G.7 Classification criteria
Annex H (informative) Schematic description of the test procedure
      H.1 Preconditioning
      H.2 Production of migration water at 23 degree C
      H.3 Typical Schedule
          H.3.1 Preconditioning
          H.3.2 Production of migration waters
Annex I (informative) Procedural tests using standard additions
        (positive controls)
Bibliography

Defines a method to determine the migration of substances from factory made cementitious products into test waters after contact with the products.

This European Standard specifies a method to determine the migration of substances from factory made cementitious products into test waters after contact with the products. This European Standard is applicable to factory made cementitious products, e.g. cement mortar linings to metallic pipes, tanks, concrete pipes etc., intended to be used for the transport and storage of water intended for human consumption, including raw water used for the production of drinking water.

Committee
EH/6
DevelopmentNote
Supersedes 05/30083256 DC. (01/2008)
DocumentType
Standard
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

EN ISO 7393-1 : 2000 WATER QUALITY - DETERMINATION OF FREE CHLORINE AND TOTAL CHLORINE - PART 1: TITRIMETRIC METHOD USING N,N-DIETHYL-1,4-PHENYLENEDIAMINE
ISO 16132:2016 Ductile iron pipes and fittings — Seal coats for cement mortar linings
ISO/TR 13530:1997 Water quality Guide to analytical quality control for water analysis
EN 1015-11 : 1999 AMD 1 2006 METHODS OF TEST FOR MORTAR FOR MASONRY - PART 11: DETERMINATION OF FLEXURAL AND COMPRESSIVE STRENGTH OF HARDENED MORTAR
EN 1015-2:1998/A1:2006 METHODS OF TEST FOR MORTAR FOR MASONRY - PART 2: BULK SAMPLING OF MORTARS AND PREPARATION OF TEST MORTARS
EN 196-1:2016 Methods of testing cement - Part 1: Determination of strength
ENV ISO 13530 : DRAFT 1998 WATER QUALITY - GUIDE TO ANALYTICAL QUALITY CONTROL FOR WATER ANALYSIS
EN 12390-1:2012 TESTING HARDENED CONCRETE - PART 1: SHAPE, DIMENSIONS AND OTHER REQUIREMENTS FOR SPECIMENS AND MOULDS
EN 12390-2:2009 Testing hardened concrete - Part 2: Making and curing specimens for strength tests
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
EN 12350-1:2009 Testing fresh concrete - Part 1: Sampling
EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)
ISO 7393-2:1985 Water quality Determination of free chlorine and total chlorine Part 2: Colorimetric method using N,N-diethyl-1,4-phenylenediamine, for routine control purposes
ISO 10523:2008 Water quality — Determination of pH
EN 10088-1:2014 Stainless steels - Part 1: List of stainless steels

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.