1 Scope
2 Normative references
3 Objectives
3.1 Emission
3.2 Immunity
4 Definitions
4.1 Conventional value
4.2 Conventional load
4.3 Duty cycle; duty factor (X)
4.4 Conventional welding current (1-2)
4.5 Conventional load voltage (U2)
4.6 Rated supply current (I1)
5 Conditions during testing
6 Test set-up for emission and immunity
6.1 General requirements
6.2 Wire feeders
6.3 Remote controls
6.4 Ancillary equipment
6.5 Arc striking and stabilizing devices
6.6 Measuring equipment
7 Emission tests
7.1 Test conditions
7.1.1 Welding power source
7.1.2 Conventional load
7.1.2.1 Manual metal arc welding with covered electrodes
7.1.2.2 Tungsten inert gas welding
7.1.2.3 Metal inert/active gas and self-shielded flux
        cored welding
7.1.2.4 Submerged arc welding
7.1.2.5 Plasma cutting
7.1.3 Wire feeders
7.1.4 Arc striking and stabilizing devices
7.2 Emission limits
7.2.1 Background
7.2.2 Conducted emission limits
7.2.3 Radiated emission limits
8 Immunity tests
8.1 Classification and applicability of tests
8.1.1 Category 1
8.1.2 Category 2
8.2 Test conditions
8.3 Immunity performance criteria
8.3.1 Performance criteria A
8.3.2 Performance criteria B
8.3.3 Performance criteria C
8.4 Immunity levels
9 Documentation for the purchaser/user
Figures
1 Typical arc welding installation with a
        conventional load
2 Position of welding equipment and conventional
        load with respect to the antenna
3 Test set-up for arc striking and stabilizing
        devices
Tables
1 Mains terminal disturbance voltage limits for arc
        welding installations
2 Electromagnetic radiation disturbance limits
        for arc welding installations
3 Immunity levels - enclosure
4 Immunity levels - A.C. input power port
5 Immunity levels - Ports for process measurement
        and control lines
6 Immunity levels - A.C. input power port
        (informative)
Annex
A Installation and use

Applies to arc welding and allied process equipment to be used in industrial and domestic establishments, including welding power sources, wire feeders and ancillary equipment, for instance water coolers and arc striking and stabilizing devices. (frequency range 0Hz to 400 GHz) Does not apply to arc welding torches, guns, electrode holders, cables and coupling devices.

Committee
WEE/6
DevelopmentNote
DRAFT FOR COMMENT 94/711753 DC
DocumentType
Standard
Pages
16
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NF EN 50199 : 1997 Identical
NEN EN 50199 : 1996 C1 1998 Identical
I.S. EN 50199:1996 Identical
EN 50199 : 95 AC 98 Identical
AS/NZS 3652(INT):1998 Identical
SN EN 50199 : 1995 Identical
NBN EN 50199 : 1996 Identical

EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
ENV 50140 : 1993 ELECTROMAGNETIC COMPATIBILITY - BASIC IMMUNITY STANDARD - RADIATED, RADIO-FREQUENCY ELECTROMAGNETIC FIELD - IMMUNITY TEST
EN 55014 : 93 AMD 1 97 LIMITS AND METHODS OF MEASUREMENT OF RADIO DISTURBANCE CHARACTERISTICS OF ELECTRICAL MOTOR-OPERATED & THERMAL APPLIANCES FOR HOUSEHOLD AND SIMILAR PURPOSES, ELECTRIC TOOLS, ETC. AND SIMILAR ELECTRICAL APPLIANCES
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
IEC 60050-851:2008 International Electrotechnical Vocabulary (IEV) - Part 851: Electric welding
CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
EN 60974-1:2012 Arc welding equipment - Part 1: Welding power sources
EN 50192:1995 Arc welding equipment - Plasma cutting systems for manual use

View more information
US$170.10
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.