• There are no items in your cart

BS EN 55103-2:2009

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electromagnetic compatibility. Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use Immunity
Available format(s)

Hardcopy , PDF

Superseded date

11-30-2017

Language(s)

English

Published date

07-31-2012

1 Scope
2 Normative references
3 Definitions
4 Electromagnetic environment
5 Disturbing phenomena
6 Immunity requirements
7 Testing
8 Documentation for the purchaser/user
Annex A (normative) - Method of measurement of
        immunity to radiated magnetic fields,
        50 Hz to 10 kHz
Annex B (normative) - Methods of measurement
        of common mode immunity for balanced
        signal and control ports intended to be
        connected to cables whose total length
        according to the manufacturer's specification
        may exceed 10 m; 50 Hz to 10 kHz
Annex C (informative) - Apparatus using infra-red
        radiation for open-air transmission purposes
Annex D (informative) - Guidance for test houses
        on immunity testing of audio, video, audio-visual
        and entertainment lighting control apparatus
        for professional use
Annex E (informative) - Background information
        about this standard
Annex ZZ (informative) - Coverage of Essential
         Requirements of EC Directives
Bibliography
National Annex NA (informative) - Text of IS1 to E
                  N 55103-2:2009

Pertains to professional audio, video, audio-visual and entertainment lighting control apparatus as defined in 3.6 intended for use in the environments described in Clause 4.

This European Standard for EMC immunity requirements applies to professional audio, video, audio-visual andentertainment lighting control apparatusas defined in 3.6 intended for use in the environmentsdescribed in Clause 4. Thisincludes the digital apparatus definedin 3.5 and sub-assemblies, see 7.4.

Disturbances in the frequency range 0 Hz to 400 GHz are covered, but requirements are not establishedover the whole of that range.

NOTE 1 In Annex C, information is included on infra-red radiation in the wavelength range 0,7 μm to 1,6 μm.

The objective of this standard is to define the immunity test requirements, test signals, performance criteria and test methods for apparatus defined in the scope, in relation to electromagnetic immunity to continuous and transient conducted and radiated electromagnetic disturbances including electrostatic discharges. These test requirements represent essential electromagnetic compatibility requirements.

Fault conditions of source or victim apparatus are not taken into account.

Apparatus asdefined in 3.4, 3.5 and 3.6 may be operated with any source of power.

NOTE 2 Sources of power may include, for example: the publiclow-voltage supply; private supplies with similar characteristics; ad.c. source provided specifically for the apparatus; batteries internal to the apparatus; stand-by generators. Some standards may not apply to private low-voltage supplies.

NOTE 3 If it is intended to use a hand-held transmitter in proximity, additional mitigation measures may have to be employed to increase the electromagnetic immunity further, beyond the specified limits.

This European Standard does not apply to

  • consumer apparatus,

  • apparatus specifically designed for security systems,

  • apparatus designed to radiate electromagnetic energy for radio communications purposes.

Committee
GEL/210
DevelopmentNote
Supersedes 95/207380 DC (07/2004) Supersedes 11/30248811 DC. (07/2012)
DocumentType
Standard
Pages
40
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

CISPR 20:2006+AMD1:2013 CSV Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 55020:2007/A12:2016 SOUND AND TELEVISION BROADCAST RECEIVERS AND ASSOCIATED EQUIPMENT - IMMUNITY CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 20:2006)
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
HD 483.1 : 200S2 SOUND SYSTEM EQUIPMENT - GENERAL
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 60268-1:1985 Sound system equipment. Part 1: General
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 55103-1:2009/A1:2012 ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD FOR AUDIO, VIDEO, AUDIO-VISUAL AND ENTERTAINMENT LIGHTING CONTROL APPARATUS FOR PROFESSIONAL USE - PART 1: EMISSIONS
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
US$261.13
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.