BS EN 60127-6:2014
Current
The latest, up-to-date edition.
Miniature fuses Fuse-holders for miniature fuse-links
Hardcopy , PDF
English
11-30-2014
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Preferred standard ratings and classifications for
fuse-holders
6 Marking
7 Clause deleted
8 General notes on tests
9 Protection against electric shock
10 Clearances and creepage distances
11 Electrical requirements
12 Mechanical requirements
13 Thermal requirements
14 Endurance
15 Additional requirements
Annex A (normative) - Test PC board for fuse-holders of rated currents
up to 10 A
Annex B (normative) - Type tests, test sequences and number of
samples
Annex C (informative) - Insulation coordination
Annex D (informative) - Additional tests and requirements
Annex E (informative) - Information for the correct application of
the fuse-holder
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding
European publications
Describes uniform requirements for safety and the assessment of electrical, mechanical, thermal and climatic properties of fuse-holders and the compatibility between fuse-holders and fuse-links.
This part of IEC60127 is applicable to fuse-holders for miniature cartridge fuse-links according to IEC60127‑2 and sub-miniature fuse-links according to IEC60127‑3 for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. Examples of fuse-holder types with different features are given in Table1. Table1 Features of unexposed or exposed fuse-holders 1 Types of mounting 1.1 Panel and base mounting 1.2 Printed circuit board mounting 2 Methods of fastening 2.1 Methods of fastening on panel: 2.1.1 Fixing nut fastening (threaded nut) 2.1.2 Snap-in fastening: 2.1.2.1 Fuse-base with an integral spring system 2.1.2.2 Fuse-base with a separate spring-nut (a nut fabricated, e.g. from thin spring steel having an impression designed to accommodate the mating part) 2.2 Methods of fastening on printed circuit (PC) board: 2.2.1 Solder fastening 2.2.2 Plug-in fastening 3 Methods of insertion of the fuse-carrier into the fuse base 3.1 Screw insertion 3.2 Bayonet insertion 3.3 Plug-in insertion 4 Types of terminals 4.1 Screw terminals 4.2 Solder terminals 4.3 Quick connect terminals 4.4 Other solderless terminals: - crimp terminals - wire wrap terminals 5 Protection against electric shock 5.1 Fuse-holder without integral protection against electric shock 5.2 Fuse-holder with integral protection against electric shock 5.3 Fuse-holder with enhanced integral protection against electric shock NOTE This list is not intended to be comprehensive and fuse-holders which are not listed are not necessarily excluded from the scope. This part of IEC60127 applies to fuse-holders with: a maximum rated current of 16A; and a maximum rated voltage of 1500V d.c. or 1000V a.c.; and for use up to 2000m above sea-level, unless otherwise specified. The object of this standard is to establish uniform requirements for safety and the assessment of electrical, mechanical, thermal and climatic properties of fuse-holders and the compatibility between fuse-holders and fuse-links.
Committee |
PEL/32
|
DevelopmentNote |
Supersedes 00/200718 DC, 90/33780 DC and 94/200241 DC. (08/2003) 1994 Edition along with its amendments remain current and will be withdrawn on 08/10/2017. Supersedes 12/30259014 DC. (11/2014)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
DIN EN 60127-6 : 2015 | Identical |
NBN EN 60127-6 : 2014 | Identical |
NF EN 60127-6 : 2014 | Identical |
EN 60127-6:2014 | Identical |
IEC 60127-6:2014 | Identical |
I.S. EN 60127-6:2014 | Identical |
UNE-EN 60127-6:1997 | Identical |
SN EN 60127-6 : 2014 | Identical |
BS 1075:1989 | Specification for tungsten halogen lamps (non vehicle) |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 60127-3:2015 | Miniature fuses - Part 3: Sub-miniature fuse-links |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60127-1:2006/A2:2015 | MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60050-212:2010 | International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
EN 60127-3:2015 | Miniature fuses - Part 3: Sub-miniature fuse-links |
EN 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60060-3:1976 | High-voltage test techniques - Part 3: Measuring devices |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60068-3-4:2002 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-3-4:2001 | Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60695-11-5 : 2.0 | FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.