• There are no items in your cart

BS EN 60627:2015

Current
Current

The latest, up-to-date edition.

Diagnostic X-ray imaging equipment. Characteristics of general purpose and mammographic anti-scatter grids
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

06-30-2015

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Structure of ANTI-SCATTER GRIDS
5 Measurement and determination of physical characteristics
6 Requirements for ANTI-SCATTER GRIDS
Annex A (normative) - Calculation of the APPLICATION
        LIMITS
Annex B (informative) - Influence of scatter fraction on
        the physical characteristics
Bibliography
Index of defined terms used in this standard
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZZ (informative) - Coverage of Essential
         Requirements of EU Directives

Pertains to ANTI-SCATTER GRIDS used in medical diagnostic Xray imaging equipment. ANTI-SCATTER GRIDS are used to reduce the incidence of SCATTERED RADIATION, produced particularly in the body of the PATIENT, upon the IMAGE RECEPTION AREA and thus to improve the contrast of the X-RAY PATTERN.

IEC 60627:2013 is applicable to anti-scatter grids used in medical diagnostic X-ray imaging equipment. Anti-Scatter Grids are used to reduce the incidence of scattered radiation, produced particularly in the body of the patient, upon the image reception area and thus to improve the contrast of the X-ray pattern. This International Standard specifies the definitions, determination and indication of characteristics of anti-scatter grids. In this standard only linear grids are considered. Since at present only focused grids are used in mammography, this standard is restricted to focused grids where mammographic anti-scatter grids are concerned. This standard is not intended to be applied for acceptance tests. This standard does not cover the homogeneity of performance over the area of a grid. This standard is intended to be applied for the determination of the characteristics of anti-scatter grids under test conditions. These conditions are not usually available at the site of the responsible organization. This third edition cancels and replaces the second edition published in 2001, and constitutes a technical revision. In this revision calcium tungstate phosphor fluorescent screens, which are no longer available, have been replaced by gadolinium oxysulphide (GOS) fluorescent screens. Further, a new quality parameter is introduced: the Image Improvement Factor or Q-factor, which better describes the properties of the anti-scatter grid, especially for digital detector applications. Further differences between this third edition and the previous second edition are:
- new instrumentation is prescribed for measurements of the transmission of primary radiation, the transmission of scattered radiation and the transmission of total radiation, because fluorescent screens made of calcium tungstate phosphors are outdated and are no longer available;
- the definition of the phantom used for measurements of the transmission of primary radiation, the transmission of scattered radiation and the transmission of total radiation is modified and references to IEC 61267 are omitted;
- and the radiation conditions used for the measurements have been adapted and are now the RQR and RQR-M conditions specified in IEC 61267:2005.

Committee
CH/62/2
DevelopmentNote
Supersedes 99/563722 DC and BS 5913(1980) (12/2001) 2001 Edition along with its amendment remains current and will be withdrawn on 14/04/2018. Supersedes 11/30227744 DC. (06/2015)
DocumentType
Standard
Pages
42
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
NF EN 60627 : 2015 Identical
EN 60627:2015 Identical
I.S. EN 60627:2015 Identical
IEC 60627:2013 Identical
NBN EN 60627 : 2015 Identical
DIN EN 60627:2016-08 Identical
UNE-EN 60627:2002 Identical

EN 60601-1-3 : 2008 AMD 11 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008/A1:2013)
EN 61267:2006 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
IEC 61267:2005 Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics

View more information
US$261.13
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.