• There are no items in your cart

BS EN 60793-1-45:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Optical fibres Measurement methods and test procedures - Mode field diameter

Available format(s)

Hardcopy , PDF

Superseded date

02-22-2018

Language(s)

English

Published date

04-26-2004

INTRODUCTION
1 Scope
2 Normative references
3 Reference test method
4 Apparatus
  4.1 Light source
  4.2 Input optics
  4.3 Input positioner
  4.4 Cladding mode stripper
  4.5 High-order mode filter
  4.6 Output positioner
  4.7 Output optics
  4.8 Detector
  4.9 Computer
5 Sampling and specimens
  5.1 Specimen length
  5.2 Specimen end face
6 Procedure
7 Calculations
  7.1 Method A - Direct far-field scan
  7.2 Method B - Variable aperture in the far field
  7.3 Method C - Near-field scan
8 Results
  8.1 Information to be provided with each measurement
  8.2 Information available upon request
9 Specification information
Annex A (normative) Requirements specific to method A -
        Mode field diameter by direct far-field scan
Annex B (normative) Requirements specific to method B -
        Mode field diameter by variable aperture in the
        far field
Annex C (normative) Requirements specific to method C -
        Mode field diameter by near-field scan
Annex D (normative) Requirements specific to method D -
        Mode field diameter by optical time domain
        reflectometer (OTDR)
Annex E (informative) Sample data sets and calculated values
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Covers uniform requirements for measuring the mode field diameter (MFD) of optical fibre, thereby assisting in the inspection of fibres and cables for commercial purposes.

Establishes requirements for measuring the mode field diameter (MFD) of fibres. Four methods are described: (a) direct far-field scan: (b) variable aperture in the far field: (c) near-field scan: (d) bi-directional backscatter using an optical time domain reflectometer. All four methods apply to type B single-mode fibres, operating near 1310 nm or 1550 nm. The contents of the corrigendum of July 2002 have been included in this copy.

Committee
GEL/86/1
DevelopmentNote
Partially supersedes BS EN 188000 Supersedes 98/262951 DC (05/2004)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60793-1-45:2017 Identical
I.S. EN 60793-1-45:2004 Identical
IEC 60793-1-45 : 2.0 Identical
NF EN 60793-1-45 : 2004 Identical
DIN EN 60793-1-45 : 2004 Identical
EN 60793-1-45 : 2018 Identical

IEC 60793-2:2015 Optical fibres - Part 2: Product specifications - General
EN 60793-1-40:2003 Optical fibres - Part 1-40: Measurement methods and test procedures - Attenuation
IEC 60793-1-40:2001 Optical fibres - Part 1-40: Measurement methods and test procedures - Attenuation

View more information
US$277.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.