• There are no items in your cart

BS EN 61300-3-3:2009

Current
Current

The latest, up-to-date edition.

Fibre optic interconnecting devices and passive components. Basic test and measurement procedures Examinations and measurements. Active monitoring of changes in attenuation and return loss
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

05-31-2009

1 Scope
2 Normative references
3 General description
  3.1 Test method
  3.2 Precautions
4 Apparatus
  4.1 Methods 1, 2 and 3
      4.1.1 General
      4.1.2 Source (S)
      4.1.3 Launch condition (E)
      4.1.4 Monitoring equipment
      4.1.5 Detector D
      4.1.6 Stress fixture
      4.1.7 Branching device BD
      4.1.8 Temporary joints
      4.1.9 Data acquisition
      4.1.10 Monitor sample
      4.1.11 Reference fibre
  4.2 Methods 4 and 5
      4.2.1 General
      4.2.2 OTDR
      4.2.3 Buffer fibre
      4.2.4 Optical switches
5 Procedure
  5.1 Monitoring attenuation and return loss of a single
      sample - method 1
      5.1.1 General
      5.1.2 Attenuation monitoring - method 1
      5.1.3 Return loss monitoring - method 1
  5.2 Monitoring attenuation and return loss of multiple
      samples using a 1 x N branching device -
      method 2
      5.2.1 General
      5.2.2 Attenuation monitoring - method 2
      5.2.3 Return loss monitoring - method 2
  5.3 Monitoring attenuation and return loss of multiple
      samples using two 1 x N optical switches -
      method 3
      5.3.1 General
      5.3.2 Attenuation - method 3
      5.3.3 Return loss - method 3
  5.4 Bidirectional OTDR monitoring of attenuation
      and return loss of multiple samples -
      method 4
      5.4.1 General
      5.4.2 Attenuation - method 4
      5.4.3 Return loss - method 4
  5.5 Unidirectional OTDR monitoring of attenuation
      and return loss of multiple samples -
      method 5
6 Details to be specified
  6.1 Method 1
  6.2 Methods 2 and 3
  6.3 Methods 4 and 5
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Specifies the procedure to monitor changes in attenuation and/or return loss of a component or an interconnecting device, when subjected to an environmental or mechanical test.

IEC 61300-3-3:2009 describes the procedure to monitor changes in attenuation and/or return loss of a component or an interconnecting device, when subjected to an environmental or mechanical test. Such a procedure is commonly referred to as active monitoring. In many instances, it is more efficient to monitor attenuation and return loss at the same time. This edition constitutes a minor revision. The change with respect to the previous edition is the structure of the document.

Committee
GEL/86/2
DevelopmentNote
Supersedes 01/202728 DC (05/2003) Supersedes 95/212100 DC. (03/2007) Supersedes 07/30172982 DC. (06/2009)
DocumentType
Standard
Pages
24
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
UNE-EN 61300-3-3:2004 Identical
SN EN 61300-3-3 : 1997 Identical
NF EN 61300-3-3 : 2016 Identical
I.S. EN 61300-3-3:2009 Identical
IEC TR 62691:2016 Identical
DIN EN 61300-3-3:2009-12 Identical
EN 61300-3-3:2009 Identical
IEC 61300-3-3:2009 Identical

EN 61300-1:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance
EN 61300-3-1:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination
IEC 61300-1:2016 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1: General and guidance
IEC 61300-3-6:2008 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss
EN 61300-3-6:2009 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6: Examinations and measurements - Return loss
IEC PAS 61300-3-35:2002 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-35: Examinations and measurements - Fibre optic cylindrical connector endface visual inspection
IEC 61300-3-1:2005 Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1: Examinations and measurements - Visual examination

View more information
US$222.80
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.