• There are no items in your cart

BS EN 62271-103:2011

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

High-voltage switchgear and controlgear Switches for rated voltages above 1 kV up to and including 52 kV
Available format(s)

Hardcopy , PDF

Superseded date

12-12-2023

Language(s)

English

Published date

12-31-2013

1 General
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
5 Design and construction
6 Type tests
7 Routine tests
8 Guide to the selection of switchgear and
   controlgear
9 Information to be given with inquiries, tenders
   and orders
10 Transport, storage, installation, operation and
   maintenance
11 Safety
12 Influence of the product on the environment
Annex A (normative) - Tolerances on test quantities
        for type tests
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Annex ZB (informative) - A-deviations

Pertains to three-phase, alternating current switches and switch-disconnectors for their switching function, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV up to and including 52 kV and for rated frequencies from 16[2/3] Hz up to and including 60 Hz.

This part of IEC 62271 is applicable to three-phase, alternating current switches and switch - disconnectors for their switching function, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages above 1 kV up to and including 52 kV and for rated frequencies from 16 2/3 Hz up to and including 60 Hz. This standard is also applicable to single-pole switches used on three phase systems.

This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.

Switch-disconnectors are also covered by IEC 62271-102 for their disconnecting function.

Devices that require a dependent manual operation are not covered by this standard.

General principles and provisions of this standard may also be applicable to single pole switches intended for application in single -phase systems. The requirements for dielectric tests and making and breaking tests should be in accordance with the requirements of the specific application.

This standard establishes requirements for general, limited and special purpose switches used in distribution systems.

It is assumed that opening and closing operations are performed according to the manufacturer\'s instructions. A making operation may immediately follow a breaking operation but a breaking operation should not immediately follow a making operation since the current to be broken may then exceed the rated breaking current of the switch.

NOTE 1 Except where special clarification is required, the term “switch” is used to refer to all kinds of switches and switch-disconnectors within the scope of this standard.

NOTE 2 Earthing switches are not covered by this standard. Earthing switches forming an integral part of a switch are covered by IEC 62271-102.

NOTE 3 This standard is not applicable to switching devices attached as an accessory to a high -voltage fuse assembly or its mounting and operated by opening and closing the fuse assembly.

Committee
PEL/17
DevelopmentNote
Supersedes BS EN 60265-1. Supersedes 08/30184562 DC. (09/2011)
DocumentType
Standard
Pages
72
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
EN 62424:2009 Identical
IEC 62271-103:2011/COR1:2013 Identical
EN 62271-103:2011 Identical
IEC 62271-103:2011 Identical

IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 62271-110:2017 High-voltage switchgear and controlgear - Part 110: Inductive load switching
IEC 62271-105:2012 High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
EN 62271-102:2002/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60059:1999+AMD1:2009 CSV IEC standard current ratings
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches

View more information
US$356.96
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.