• There are no items in your cart

BS IEC 61000-5.2 : 1997

Current
Current

The latest, up-to-date edition.

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-1997

FOREWORD
INTRODUCTION
1 Scope
2 Reference documents
3 Definitions
4 General EMC considerations on installation of earthing
    and cabling systems
5 Earthing and bonding
6 bonding
7 Cables and wires
8 Additional interference mitigation methods
9 Measuring and testing methods
Figures
1 Demonstration of the fallacy of te "equipotentiality"
    concept as a universal rule
2 Schematic plan view of a typical earth electrode
3 Misconception of "dedicated", independent", or "isolated"
    earth electrodes
4 The concept of a single earth electrode
5 Recommended configuration for the earth electrodes and
    earthing network
6 Loops involving signal cables and earthing network
7 A three-dimensional schematic of the recommended approach
    for the earthing network
8 General principles for bonding of various apparatus or
    systems to the earthing network
9 Simplified representation of a bonding strap
10 A more realistic representation of an installed bonding
    strap
11 Typical bonding straps
12 Relative inductance of flat and round conductors
13 Relative inductance of round, flat and double bonding
    straps
14 Example of protected removable connection of a bonding strap
15 Example of optimal bonding of a shielded cable to the
    enclosure
16 Schematic of interconnected chassis
17 Differential mode and common mode circuits with bonding
    strips and signal cables
18 Effect of the configuration of a parallel-earthing
    conductor on the transfer impedance
19 Slits in conduits and cable trays
20 Recommended configuration for cable trays with branches
21 Recommended cable positions parallel to an H-shaped
    beam from the EMC point of view
22 Penetration of a shielded cable through an enclosure wall
23 Tray with partition
24 Example of stacking for conduits or trays
25 Topology of circuits containing switches
26 Undesirable connection of a coaxial cable
27 Typical implementations of common-mode ferrite chokes
28 Limitations in the effectiveness of an isolation transformer
29 Parasitic coupling at high frequencies
Annexes
A Examples of earthing systems and cable implementation
B Applying cable theory to enhance EMC
C Benefits of additional conductors parallel to a cable
D Bibliography
Annex figures
A.1 Example of topology for a hybrid earthing system
A.2 EMC cabinet for the protection of sensitive electronics
A.3 Earthing system for a drive with converter and
      associated electronics
A.4 Earthing configuration for a power supply system with
      associated electronics
A.5 Initial arrangement of the power and control cables
A.6 Improved design with appropriate shield connections
B.1 Unbalanced transport of signals
B.2 Behaviour of Zt as function of frequency for several
      coaxial cable configurations
B.3 Unbalanced transmission system connected to earth at one
      end
B.4 Balanced transmission system
B.5 Current paths in a coaxial cable
B.6 Differential-mode voltage induced by a magnetic field
      in a cable with braided shield
B.7 Currents in the outer conductor of a coaxial cable
B.8 A two-lead cable perturbed by a nearby lead at the voltage
      Uext
C.1 Coaxial cables with parallel-earthing conductors
C.2 A coaxial cable with two outer conductors
C.3 Transfer impedances in a shielded balanced pair
C.4 Example of transfer impedance for an aluminium conduit as
      a function of frequency
C.5 Mutual inductance and magnetic field for a conduit or
      cable tray
C.6 Insulated covers over a conduit

Gives guidelines for earthing and cabling of electrical and electronic systems and installations for ensuring electromagnetic compatibility among electrical and electronic apparatus or systems. Concerned with earthing practices and cables used in industrial, commercial and residential installations.

Committee
GEL/210/12
DevelopmentNote
Supersedes 95/214642 DC (08/2004)
DocumentType
Standard
Pages
72
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
IEC TR 61000-5-2:1997 Identical

BS 7671(2008) : 2018 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
11/30249994 DC : DRAFT JULY 2011 BS 7430 - CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS
BS 6739:2009 Code of practice for instrumentation in process control systems: installation design and practice
07/30130630 DC : 0 BS 7430 - CODE OF PRACTICE FOR EARTHING
08/30136724 DC : DRAFT MAY 2008 BS 6739 - CODE OF PRACTICE FOR INSTRUMENTATION IN PROCESS CONTROL SYSTEMS - INSTALLATION DESIGN AND PRACTICE
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS

IEC 61024-1:1990 Protection of structures against lightning - Part 1: General principles
ISO/IEC 11801:2002 Information technology Generic cabling for customer premises
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC TR 61000-5-1:1996 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication

View more information
US$335.40
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.