FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 General
  4.2 Requirements for EMC immunity
      4.2.1 Degrees of severity of tests for EMC immunity
      4.2.2 Safety system equipment
5 Test methods
  5.1 General
  5.2 Test results assessment
6 Safety requirements
Annex A (normative) - Functional quality criteria of nuclear
        I&C equipment under test for disturbance immunity
Annex B (informative) - Quality characteristics defining the
        classification of electromagnetic environment
        severity in the locations where nuclear I&C
        equipment is to be installed
Annex C (informative) - Guidance for tests and evaluation of
        conformance with the requirements for disturbance
        immunity of operating nuclear I&C equipment
Annex D (informative) - Example form of test report for
        nuclear I&C equipment tests for disturbance
        immunity
Annex E (informative) - Emissions testing guidelines
Bibliography

Describes requirements for electromagnetic compatibility testing of instrumentation and control equipment supplied for use in systems important to safety at nuclear power plants.

IEC 62003:2009 establishes requirements for electromagnetic compatibility testing of instrumentation and control equipment supplied for use in systems important to safety at nuclear power plants. Lists the applicable IEC standards (principally the IEC 61000 series) which define the general test methods, and provides the necessary application-specific parameters and criteria to ensure that nuclear safety requirements are met.

Committee
NCE/8
DevelopmentNote
Supersedes 07/30165539 DC. (06/2009)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 62003:2009 Identical

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 61000-4-10 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-10: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY MAGNETIC FIELD IMMUNITY TEST
IEC 61000-6-4:2006+AMD1:2010 CSV ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC TR 61000-1-5:2004 Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
IEC 62310-2:2006 Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
EN 50091-2:1995/corrigendum Jan. 1998
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-12 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-12: TESTING AND MEASUREMENT TECHNIQUES - RING WAVE IMMUNITY TEST
IEC 60255-22-5:2008 Measuring relays and protection equipment - Part 22-5: Electrical disturbance tests - Surge immunity test
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 61000-6-6:2003 Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
IEC 61000-4-9 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-9: TESTING AND MEASUREMENT TECHNIQUES - IMPULSE MAGNETIC FIELD IMMUNITY TEST
IEC 61000-4-28:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-28: Testing and measurement techniques - Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
IEC TS 61000-6-5:2001 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-4-14:1999+AMD1:2001+AMD2:2009 CSV Electromagnetic compatibility (EMC) - Part 4-14: Testing and measurement techniques - Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 61000-4-23:2016 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC TR 61000-2-8:2002 Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-2-13:2005 Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted
IEC 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)
IEC 61000-4-16 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-16: TESTING AND MEASUREMENT TECHNIQUES - TEST FOR IMMUNITY TO CONDUCTED, COMMON MODE DISTURBANCES IN THE FREQUENCY RANGE 0 HZ TO 150 KHZ

View more information
US$277.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.