• There are no items in your cart

BS ISO 30011:2010

Current
Current

The latest, up-to-date edition.

Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-31-2011

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Requirements
6 Reagents
7 Laboratory apparatus
8 Procedure
9 Expression of results
10 Method performance
11 Test report
Annex A (informative) - ICP-MS principles and interferences
Annex B (informative) - Guidance on maintenance of ICP-MS
        instrumentation
Annex C (informative) - Recalculation of metal and metalloid
        in air concentrations to reference conditions
Bibliography

Defines a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202-1.

This International Standard specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO15202-1. Method development, performance checks, and a routine analysis method are specified. Test solutions for analysis by this International Standard are prepared as specified in ISO15202-2. This International Standard is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values (seee.g. EN689[10], ASTM E1370[8]). The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [15]) and for which one or more of the sample preparation methods specified in ISO15202-2 and the analytical procedure described in this International Standard are applicable. However, there is no information available on the effectiveness of any of these sample preparation methods for those elements listed in italics. aluminium caesium lead platinum tungsten antimony chromium lithium potassium uranium arsenic cobalt magnesium rhodium vanadium barium copper manganese selenium yttrium beryllium gallium mercury silver zinc bismuth germanium molybdenum sodium zirconium boron hafnium nickel tellurium cadmium indium niobium thallium calcium iron phosphorus tin This International Standard is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO15202-1. The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2l min−1 for sampling times in the range 0,5h to 8h and for assessment of exposure against the short-term exposure limits, where applicable. The procedure is subject to no significant spectral interferences (see A.3), provided that suitable analytical isotopes are used. However, inadequate matrix-matching can adversely affect results.

Committee
EH/2/2
DevelopmentNote
Supersedes 09/30165939 DC. (02/2011)
DocumentType
Standard
Pages
46
PublisherName
British Standards Institution
Status
Current
Supersedes

Standards Relationship
ISO 30011:2010 Identical

ASTM E 1370 : 2014 : REDLINE Standard Guide for Air Sampling Strategies for Worker and Workplace Protection
ISO 8655-5:2002 Piston-operated volumetric apparatus Part 5: Dispensers
ISO 8655-1:2002 Piston-operated volumetric apparatus Part 1: Terminology, general requirements and user recommendations
ISO 3585:1998 Borosilicate glass 3.3 Properties
ISO 1042:1998 Laboratory glassware One-mark volumetric flasks
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
EN 13890:2009 Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods
ISO 15202-1:2012 Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 1: Sampling
EN 14902:2005/AC:2006 AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB, CD, AS AND NI IN THE PM10 FRACTION OF SUSPENDED PARTICULATE MATTER
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
ISO 3534-2:2006 Statistics Vocabulary and symbols Part 2: Applied statistics
ASTM D 7439 : 2014 : REDLINE Standard Test Method for Determination of Elements in Airborne Particulate Matter by Inductively Coupled Plasma–Mass Spectrometry
ISO 9004:2009 Managing for the sustained success of an organization A quality management approach
ISO 8655-2:2002 Piston-operated volumetric apparatus Part 2: Piston pipettes
EN 1540:2011 Workplace exposure - Terminology
ISO 17294-2:2016 Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes
ISO 8655-6:2002 Piston-operated volumetric apparatus Part 6: Gravimetric methods for the determination of measurement error
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
ISO 15202-2:2012 Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 2: Sample preparation

View more information
US$313.84
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.