• There are no items in your cart

PD CEN/TS 16272-7:2015

Current
Current

The latest, up-to-date edition.

Railway applications. Track. Noise barriers and related devices acting on airborne sound propagation. Test method for determining the acoustic performance Extrinsic characteristics. In situ values of insertion loss
Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

10-31-2015

European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Methods
6 Instrumentation
7 Acoustic environment
8 Sources and source equivalence
9 Measurement procedure
10 Measurement uncertainty
11 Test report
Annex A (informative) - Measurement uncertainty
Bibliography

Defines methods for the determination of insertion loss of outdoor noise barriers intended to shield railway noise.

This Technical Specification specifies methods for the determination of insertion loss of outdoor noise barriers intended to shield railway noise. It specifies detailed procedures for in situ measurement of barrier insertion loss including microphone positions, source conditions and acoustic environments of the measurement sites. This Technical Specification allows one to measure the insertion loss of a given noise barrier at a given site including given meteorological conditions. It does not make it possible to compare insertion loss values of an equivalent barrier at a different site. It can be used for comparing insertion loss values of different types of barriers at the same site under given meteorological conditions by the “direct method??. This Technical Specification gives a method for determining insertion loss: from the level difference before and after the installation of noise barriers (the “direct method??); when the direct method is not applicable, because a barrier has already been installed, using an \'indirect method\' to estimate the sound pressure levels before installation of the barrier by measurement at another site which has been judged to be equivalent. For equivalent sites, a close match is required in source characteristics, microphone locations, terrain profiles ground surface characteristics, surrounding artificial structures and meteorological conditions. This Technical Specification prescribes principles for ensuring that sufficiently equivalent conditions are maintained between “before?? and “after?? cases to permit certain, reliable and repeatable determination of barrier insertion loss. This Technical Specification does not cover the determination of the intrinsic acoustic characteristics of the barrier, for example the sound insulation index and the sound absorption coefficient. The equivalent continuous A-weighted sound pressure level and one-third-octave band sound pressure level are used as noise descriptors. This Technical Specification can be used for routine determination of barrier performance or for engineering or diagnostic evaluation. It can be used in situations where the barrier is to be installed or has already been installed.

Committee
RAE/2
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current

Standards Relationship
CEN/TS 16272-7:2015 Identical

EN 16272-3-2:2014 Railway applications - Track - Noise barriers and related devices acting on airborne sound propagation - Test method for determining the acoustic performance - Part 3-2: Normalized railway noise spectrum and single number ratings for direct field applications
IEC 60942:2003 Electroacoustics - Sound calibrators
ISO 9613-1:1993 Acoustics Attenuation of sound during propagation outdoors Part 1: Calculation of the absorption of sound by the atmosphere
EN 61672-1:2013 Electroacoustics - Sound level meters - Part 1: Specifications
IEC 61260:1995 Electroacoustics - Octave-band and fractional-octave-band filters
EN 60942:2003 Electroacoustics - Sound calibrators
EN 61260:1995/A1:2001 ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS
EN 16272-3-1:2012 Railway applications - Track - Noise barriers and related devices acting on airborne sound propagation - Test method for determining the acoustic performance - Part 3-1: Normalized railway noise spectrum and single number ratings for diffuse field applications
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

View more information
US$222.80
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.