PD CR 13825:2000

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Luer connectors. A report to CEN CHeF from the CEN forum task group \'Luer fittings\'
Available format(s)

Hardcopy , PDF

Withdrawn date

11-17-2022

Language(s)

English

Published date

06-15-2000

1 SUMMARY
2 RECOMMENDATIONS
3 BACKGROUND
4 PROBLEMS ARISING FROM THE USE OF LUER CONNECTORS
5 RISK ASSESSMENT
6 DISCUSSION
      6.1 Human factors
      6.2 Safety under single fault conditions
      6.3 Inherent safe design
      6.4 The Medical Device Directive 93/42/EEC14
7 prEN 13014: CONNECTIONS FOR GAS SAMPLING TUBES TO
      ANAESTHETIC AND RESPIRATORY EQUIPMENT
8 CONCLUSIONS
BIBLIOGRAPHY
ANNEX 1
      1.1 - THE LUER CONNECTOR
      1.2 - STANDARDS FOR LUER CONNECTORS
      1.3 - APPLICATION AND USE OF LUER CONNECTORS
ANNEX 2 - COMMONLY USED DEVICES INCORPORATING LUER CONNECTORS
ANNEX 3 - POTENTIAL PROBLEMS WITH LUER CONNECTORS

Medical devices containing Luer connectors and having a wide range of functions have an increased risk of accidental cross connection between devices. An assessment was performed on the hazards arising from accidental misconnection, and a review of adverse incidents that are known to have involved Luer connectors. Three possible strategies were implemented to reduce the risk of misconnection; the use of colour coding and the use of different male/female sequences for different applications were not found to be sufficiently effective. The only strategy found to have any real benefits was the restriction of applications for which the use of Luer connectors is permitted.

Committee
CH/84
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Withdrawn

Standards Relationship
CR 13825:2000 Identical

EN 1615 : 2000 ENTERAL FEEDING CATHETERS AND ENTERAL GIVING SETS FOR SINGLE USE AND THEIR CONNECTORS - DESIGN AND TESTING
EN 20594-1:1993/A1:1997 CONICAL FITTINGS WITH A 6% (LUER) TAPER FOR SYRINGES, NEEDLES AND CERTAIN OTHER MEDICAL EQUIPMENT - GENERAL REQUIREMENTS
EN 1707 : 1996 CONICAL FITTINGS WITH A 6 % (LUER) TAPER FOR SYRINGES, NEEDLES AND CERTAIN OTHER MEDICAL EQUIPMENT - LOCK FITTINGS

View more information
US$160.51
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.