• There are no items in your cart

CEI EN 60099-5 : 2014

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

SURGE ARRESTERS - PART 5: SELECTION AND APPLICATION RECOMMENDATIONS
Available format(s)

Hardcopy , PDF

Superseded date

03-22-2019

Language(s)

English

Published date

01-01-2014

FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General principles for the application of surge arresters
5 Surge arrester fundamentals and applications issues
6 Insulation coordination and surge arrester applications
7 Surge arresters for special applications
8 Asset management of surge arresters
Annex A (informative) - Determination of temporary
        overvoltages due to earth faults
Annex B (informative) - Current practice
Annex C (informative) - Arrester modelling techniques for
        studies involving insulation coordination and
        energy requirements
Annex D (informative) - Diagnostic indicators of metal-oxide
        surge arresters in service
Annex E (informative) - Typical data needed from arrester
        manufacturers for proper selection of surge arresters
Annex F (informative) - Typical maximum residual voltages
        for metal-oxide arresters without gaps according
        to IEC 60099-4
Annex G (informative) - Steepness reduction of incoming
        surge with additional line terminal surge capacitance
Annex H (informative) - End of life and replacement of old
        gapped SiC-arresters
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding
         European publications

Gives information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV.

Committee
CT 37
DevelopmentNote
Classificazione CEI 37-3. (08/2001)
DocumentType
Standard
Pages
152
PublisherName
Comitato Elettrotecnico Italiano
Status
Superseded
SupersededBy

Standards Relationship
IEC 60099-5:2013 Identical
EN 60099-5:2013 Identical

IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC TR 60071-4:2004 Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
IEC TS 60815-2:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
IEC 60099-6:2002 Surge arresters - Part 6: Surge arresters containing both series and parallel gapped structures - Rated 52 kV and less
EN 60507:2014 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60071-2:1996 Insulation co-ordination - Part 2: Application guide
IEC 60099-8:2017 Surge arresters - Part 8: Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
EN 60071-2:1997 Insulation co-ordination - Part 2: Application guide
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 60815-1:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
IEC TS 60815-3:2008 Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems

View more information
US$416.75
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.