• There are no items in your cart

CLC/TR 50373:2004

Current
Current

The latest, up-to-date edition.

Wind turbines - Electromagnetic compatibility
Published date

08-06-2004

Introduction
1 Scope
2 References
3 Definitions
4 Symbols and abbreviations
5 Guidance for wind turbines
  5.1 General
  5.2 Emissions
  5.3 Immunity
  5.4 Testing
  5.5 Electromagnetic compatibility inside the wind
      turbine
6 Documentation for the purchaser/user
  6.1 Documentation which may be supplied to the
      purchaser/user
  6.2 Documentation which may be provided to the
      purchaser/user upon request
7 Guidance for wind turbine installations
Bibliography

This Technical Report provides guidance on requirements for the electromagnetic compatibility of wind turbines of all sizes, to assist with achieving compliance with EMC standards. This Technical Report includes guidance on emissions, and for immunity to external disturbances.Safety related aspects are not included in this Technical Report. They are the subject of relevant parts of EN 61400.This Technical Report is applicable to electromagnetic emissions and immunity, both conducted and radiated, in the range 0 Hz to 400 GHz (although generally EMC standards do not at present contain test methods or limits at frequencies above 1 GHz). Fault conditions are not taken into account.This Technical Report does not include test procedures, conditions, limits, or reference values; these requirements are included in relevant parts of EN 61000, which are referred to in this Technical Report where necessary.This Technical Report also provides guidance for wind turbine installations (wind farms or single machines).The electromagnetic compatibility of components within the wind turbine (i.e. within enclosed parts of the wind turbine, which may include the hub, nacelle and tubular tower) with each other is solely a matter for the wind turbine manufacturer.The physical impact of the structure on the reception of radio services in the vicinity needs to be considered as a separate issue, and is not dealt with in this Technical Report. It should be noted that although experience to date has shown that physical interference to broadcasting services has caused the majority of complaints, wind turbines are capable of interfering with all radio services to some extent.

Committee
CLC/TC 88
DocumentType
Technical Report
PublisherName
European Committee for Standards - Electrical
Status
Current

Standards Relationship
UNE-CLC/TR 50373:2006 IN Identical
NEN NPR CLC/TR 50373 : 2004 Identical
PD CLC/TR 50373:2004 Identical
CEI CLC/TR 50373 : 2005 Identical

EN 61000-5-7:2001 Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code)
IEC 61000-6-4:2006+AMD1:2010 CSV ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
EN 61000-6-1:2007 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments
EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
1989/336/EEC : 1989 COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY
IEC 61000-6-1 : 3.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-1: GENERIC STANDARDS - IMMUNITY STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS
IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
EN 61400-21:2008 WIND TURBINES - PART 21: MEASUREMENT AND ASSESSMENT OF POWER QUALITY CHARACTERISTICS OF GRID CONNECTED WIND TURBINES
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
EN 61000-6-4:2007/A1:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-6-1:2016 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-4:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61000-5-5:1996 Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61400-21:2008 Wind turbines - Part 21: Measurement and assessment of power quality characteristics of grid connected wind turbines

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.