• There are no items in your cart

CLC/TS 50131-2-11:2017

Current
Current

The latest, up-to-date edition.

Alarm systems - Intrusion and hold-up systems - Part 2-11: Intrusion detectors - ALDDR
Published date

01-27-2017

European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (informative) - Free fall of mechanical cylinder
        object for interruption time testing
Annex B (informative) - Immunity to visible and
        near infrared radiation
Annex C (normative) - Dimensions and requirements of
        the standardized interference test magnet
Annex D (informative) - General testing matrix
Annex E (informative) - Example list of small tools
Annex F (informative) - Equipment for walk test
        velocity control
Annex G (informative) - Walk test diagrams
Annex H (informative) - Definition of the diffuse
        reflection material
Annex I (normative) - List of masking materials
Annex J (informative) - Definition of object against
        false detection

This Technical Specification is for ALDDR inside buildings and provides four security grades 1 to 4 (see EN 50131-1), specific or non-specific wire or wire-free ALDDR, and uses environmental classes I to IV (see EN 50130-5).An ALDDR fulfils all the requirements of the specified grade.The ALDDR detects an intruder inside a predefined area.This standard covers ALDDR using both pulsed and continuous wave laser operation technologies according to LIDAR principle (Light Detection And Ranging). Other technologies i.e. doppler based laser operation or use of additional retro-reflective objects or video based technologies are not covered by this standard.Functions additional to the mandatory functions specified in this standard may be included in the ALDDR, providing they do not adversely influence the correct operation of the mandatory functions.This Technical Specification does not apply to system interconnections.This Technical Specification does not deal with requirements for compliance with regulatory directives, such as EMC-directive, low-voltage directive, etc., except that it specifies the equipment operating conditions for EMC- susceptibility testing as required by EN 50130-4.

Committee
CLC/TC 79
DocumentType
Technical Specification
PublisherName
European Committee for Standards - Electrical
Status
Current

IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.