• CSA C22.2 NO. 84:05 (R2020)

    Current The latest, up-to-date edition.
    Add to Watchlist
    This Standard has been added successfully to your Watchlist.
    Please visit My Watchlist to see all standards that you are watching.
    Please log in or to add this standard to your Watchlist.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    We could not add this standard to your Watchlist.
    Please retry or contact support for assistance.
    You have already added this standard to your Watchlist.
    Visit My Watchlist to view the full list.

    Incandescent lamps

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  01-01-2005

    Publisher:  Canadian Standards Association

    Add to Watchlist

    Add To Cart

    Abstract - (Show below) - (Hide below)

    Preface This is the third edition of CSA C22.2 No. 84, Incandescent lamps , one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1995 and 1974. The following changes are reflected in this edition: (a) the language of the Scope has been clarified; (b) the wattage tolerance requirements have been revised; (c) there are new requirements for lamps with an integral voltage-modification device; and (d) the temperature test requirements have been revised. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. Scope 1.1 This Standard applies to medium-screwbase incandescent lamps, including double-envelope tungsten halogen types, that have right-hand threads and are intended for general lighting use in luminaires and other lighting equipment designed to be used in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard includes requirements for (a) general construction details; (b) wattage; (c) torsion resistance; (d) insulation resistance; (e) endurance testing of lamps with an integral voltage-modification device; (f) marking and marking durability; (g) lamp base temperature; and (h) lamp profile temperature. 1.3 This Standard applies to medium-screwbase incandescent lamps, including double-envelope tungsten halogen types, with (a) a rated wattage up to 300 W; (b) a rated voltage between 110 and 130 V; and (c) E26/24 single-contact, E26d double-contact, or E26/50x39 skirted bases. 1.4 This Standard does not apply to medium-screwbase incandescent lamps with a nominal voltage rating not in the 110 to 130 V range or designated exclusively for (a) industrial establishments; (b) offices; (c) exhibit space; or (d) other specialty applications. Note: Examples of excluded lamps include the following types of lamps: bowl reflector, decorative, dichroic reflector (cool beam), industrial infrared, neck reflector, novelty, painted, photographic, projection, rough service, sign, street lighting, street railway, sun lamp, traffic signal, and X-ray illuminator.

    Scope - (Show below) - (Hide below)

    Preface This is the third edition of CSA C22.2 No. 84, Incandescent lamps , one of a series of Standards issued by the Canadian Standards Association under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 1995 and 1974. The following changes are reflected in this edition: (a) the language of the Scope has been clarified; (b) the wattage tolerance requirements have been revised; (c) there are new requirements for lamps with an integral voltage-modification device; and (d) the temperature test requirements have been revised. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0. Scope 1.1 This Standard applies to medium-screwbase incandescent lamps, including double-envelope tungsten halogen types, that have right-hand threads and are intended for general lighting use in luminaires and other lighting equipment designed to be used in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard includes requirements for (a) general construction details; (b) wattage; (c) torsion resistance; (d) insulation resistance; (e) endurance testing of lamps with an integral voltage-modification device; (f) marking and marking durability; (g) lamp base temperature; and (h) lamp profile temperature. 1.3 This Standard applies to medium-screwbase incandescent lamps, including double-envelope tungsten halogen types, with (a) a rated wattage up to 300 W; (b) a rated voltage between 110 and 130 V; and (c) E26/24 single-contact, E26d double-contact, or E26/50x39 skirted bases. 1.4 This Standard does not apply to medium-screwbase incandescent lamps with a nominal voltage rating not in the 110 to 130 V range or designated exclusively for (a) industrial establishments; (b) offices; (c) exhibit space; or (d) other specialty applications. Note: Examples of excluded lamps include the following types of lamps: bowl reflector, decorative, dichroic reflector (cool beam), industrial infrared, neck reflector, novelty, painted, photographic, projection, rough service, sign, street lighting, street railway, sun lamp, traffic signal, and X-ray illuminator.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Product Note THIS STANDARD ALSO REFERS TO :CAN/CSA-C22.2 No. 0-M91 (R2001)
    Publisher Canadian Standards Association
    Status Current
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective