• There are no items in your cart

EN 12309-3:2014

Current
Current

The latest, up-to-date edition.

Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions
Published date

12-17-2014

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Test conditions
Annex ZA (informative) - Relationship between this
         European Standard and the requirements of
         Commission Regulation (EC) No 813/2013
Annex ZB (informative) - Relationship between this
         European Standard and the requirements of
         Commission Regulation (EC) No 811/2013
Bibliography

Scope of EN 12309 seriesAppliances covered by EN 12309 include one or a combination of the following:- gas-fired sorption chiller;- gas-fired sorption chiller/heater;- gas-fired sorption heat pump;EN 12309 applies to appliances only when used for space heating or cooling or refrigeration with or without heat recovery. Appliances can be monovalent, bivalent or hybrid types.EN 12309 applies to appliances having flue gas systems of type B and C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 applies to appliances that can be single ducted or double ducted. EN 12309 only applies to appliances having- integral burners under the control of fully automatic burner control systems,- closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,- mechanical means to assist transportation of the combustion air and/or the flue gas.The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in prEN 12309 1:2012) and EN 12309 applies to all such functions providing that the function concerned is dependent on circulation of fluid (refrigerant and/or solution) within the absorption, adsorption or refrigerant circuit(s).NOTE 1Any appliance function that is not dependent on circulation of the fluid within the absorption, adsorption, or refrigerant circuit(s) should be assessed separately.EN 12309 is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.In the case of packaged units (consisting of several parts), EN 12309 applies only to those designed and supplied as a complete package.EN 12309 does not apply to air conditioners.The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.NOTE 2All the symbols given in this text should be used regardless of the language used.Scope of this Part 3 to EN 12309This part of EN 12309 specifies the test conditions for the rating of energy parameters of gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW.

Committee
CEN/TC 299
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

DIN EN 12309-4 E : 2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 4: TEST METHODS
I.S. EN 12309-6:2014 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 6: CALCULATION OF SEASONAL PERFORMANCES
DIN EN 16905-3 E : 2017 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS
BS EN 12309-7:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Specific provisions for hybrid appliances
DIN EN 16905-5:2015-10 (Draft) GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 5: CALCULATION OF SEASONAL PERFORMANCES IN HEATING AND COOLING MODE
BS EN 15316-4-2:2017 Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies Space heating generation systems, heat pump systems, Module M3-8-2, M8-8-2
UNE-EN 16905-1:2017 Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions
EN 15316-4-2:2017/AC:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2
EN 12309-2:2015/AC:2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 2: SAFETY
EN 12309-7:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 7: Specific provisions for hybrid appliances
EN 12309-6:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances
EN 12309-1:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions
I.S. EN 16905-5:2017 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 5: CALCULATION OF SEASONAL PERFORMANCES IN HEATING AND COOLING MODE
15/30326266 DC : 0 BS EN 16905-5 - GAS-FIRED ENDOTHERMIC ENGINE HEAT PUMPS - PART 5: CALCULATION OF SEASONAL PERFORMANCES IN HEATING AND COOLING MODE
DIN EN 12309-7:2015-03 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 7: SPECIFIC PROVISIONS FOR HYBRID APPLIANCES
15/30326263 DC : 0 BS EN 16905-1 - GAS-FIRED ENDOTHERMIC ENGINE HEAT PUMPS - PART 1: TERMS AND DEFINITIONS
DIN EN 16905-5 E : 2017 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 5: CALCULATION OF SEASONAL PERFORMANCES IN HEATING AND COOLING MODE
I.S. EN 16905-3:2017 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS
DIN EN 16905-1:2015-10 (Draft) GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 1: TERMS AND DEFINITIONS
I.S. EN 12309-2:2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 2: SAFETY
I.S. EN 12309-1:2014 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 1: TERMS AND DEFINITIONS
DIN EN 12309-7 E : 2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 7: SPECIFIC PROVISIONS FOR HYBRID APPLIANCES
BS EN 12309-6:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Calculation of seasonal performances
DIN EN 12309-6 E : 2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 6: CALCULATION OF SEASONAL PERFORMANCES
DIN EN 12309-5:2015-03 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS
UNE-EN 12309-4:2015 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods
UNE-EN 12309-6:2015 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances
DIN EN 12309-1:2015-03 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions
DIN EN 12309-1 E : 2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 1: TERMS AND DEFINITIONS
DIN EN 12309-2 E : 2016 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 2: SAFETY
BS EN 16905-1:2017 Gas-fired endothermic engine driven heat pumps Terms and definitions
BS EN 12309-4:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Test methods
BS EN 16905-5:2017 Gas-fired endothermic engine driven heat pumps Calculation of seasonal performances in heating and cooling mode
BS EN 16905-3:2017 Gas-fired endothermic engine driven heat pumps Test conditions
15/30326257 DC : 0 BS EN 16905-3 - GAS-FIRED ENDOTHERMIC ENGINE HEAT PUMPS - PART 3: TEST CONDITIONS
BS EN 12309-5:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Requirements
DIN EN 12309-5 E : 2015 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS
I.S. EN 12309-7:2014 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 7: SPECIFIC PROVISIONS FOR HYBRID APPLIANCES
I.S. EN 12309-5:2014 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS
I.S. EN 12309-4:2014 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 4: TEST METHODS
UNE-EN 16905-5:2017 Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode
DIN EN 12309-2:2016-04 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 2: SAFETY
UNE-EN 12309-2:2015 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 2: Safety
EN 12309-4:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods
EN 16905-1:2017 Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions
EN 16905-3:2017 Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions
EN 16905-5:2017 Gas-fired endothermic engine driven heat pumps - Part 5: Calculation of seasonal performances in heating and cooling mode
DIN EN 16905-3:2015-10 (Draft) GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS
DIN EN 12309-6:2015-03 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances
DIN EN 15316-4-2:2008-09 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2
DIN EN 16905-1 E : 2017 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 1: TERMS AND DEFINITIONS
I.S. EN 16905-1:2017 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 1: TERMS AND DEFINITIONS
UNE-EN 16905-3:2017 Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions
I.S. EN 15316-4-2:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2
BS EN 12309-1:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Terms and definitions
BS EN 12309-2:2015 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Safety
I.S. EN 15316-4-2:2017+AC:2017 ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2
EN 12309-5:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements
DIN EN 16905-3:2017-09 GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS

EN 12309-1:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions
EN 12309-6:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances
EN 12309-4:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods
EN 12309-5:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements
CEN/TR 1749:2014 European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types)
EN 12309-7:2014 Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 7: Specific provisions for hybrid appliances
PREN 12309-2 : DRAFT 2013 GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 2: SAFETY

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.