EN 14637:2007

Current
Current

The latest, up-to-date edition.

Building hardware - Electrically controlled hold-open systems for fire/smoke door assemblies - Requirements, test methods, application and maintenance
Published date

11-07-2007

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviated term
4 Classification
  4.1 Coding system
  4.2 Category of use (first digit)
  4.3 Durability (second digit)
  4.4 Door type (third digit)
  4.5 Suitability for use on fire/smoke door assemblies
      (fourth digit)
  4.6 Safety (fifth digit)
  4.7 Corrosion resistance (sixth digit)
  4.8 Example of classification
5 Requirements and test methods for components of a
  hold-open system
  5.1 General
  5.2 Fire detectors
      5.2.1 Smoke detectors
      5.2.2 Heat detectors
      5.2.3 Resetting the detectors
  5.3 Power supply units
      5.3.1 All power supply units
      5.3.2 For power supply units with stand-by
             parallel operation
  5.4 Control units
      5.4.1 General
      5.4.2 Control units in stand-alone hold-open systems
             (single-line systems)
      5.4.3 Control units in fire detection and fire alarm
             systems (multi-line systems)
  5.5 Hold-open devices
      5.5.1 General
      5.5.2 Hold-open devices for swing doors
      5.5.3 Hold-open devices for sliding doors, lifting doors,
             industrial doors and roller shutters
      5.5.4 Automatic door operators
      5.5.5 Low energy/power assisted swing door
             operators
      5.5.6 Free-swing door closers
  5.6 Auxiliary equipment
      5.6.1 Manual control push-buttons and switches
      5.6.2 Presence sensors (electro-sensitive protective
             equipment)
      5.6.3 Door position sensors
      5.6.4 Remote indicating devices
      5.6.5 Manual reset
6 Requirements for the hold-open system
  6.1 Design and performance
  6.2 Product information
      6.2.1 General
      6.2.2 For installation and maintenance
      6.2.3 For initial hold-open system test
  6.3 Requirements not covered under Clause 5
  6.4 Electromagnetic compatibility (EMC)
  6.5 Additional design requirements for connection of
      components to fire alarm systems
  6.6 Electrical safety
  6.7 Durability
  6.8 Environmental behaviour
      6.8.1 Dry heat
      6.8.2 Cold
      6.8.3 Damp heat, steady state (operational)
      6.8.4 Corrosion
      6.8.5 Vibration
  6.9 Supply voltage variations
7 System tests
  7.1 General
  7.2 Test apparatus
  7.3 Theoretical analysis
  7.4 Test methods
      7.4.1 General
      7.4.2 Design verification
      7.4.3 Performance tests
      7.4.4 Check of switching device capabilities of
             the control unit
      7.4.5 Short-circuit test
      7.4.6 Electrical safety tests
      7.4.7 Electromagnetic compatibility (EMC) tests
      7.4.8 Environmental tests
      7.4.9 Corrosion test
      7.4.10 Vibration test, sinusoidal (operational)
      7.4.11 Vibration test, sinusoidal (endurance)
8 Marking
  8.1 Components
  8.2 Hold-open system
Annex A (informative) - Recommendations for planning and
                        design of the hold-open system
        A.1 General
        A.2 Restrictions
        A.3 Detectors
            A.3.1 Selection of detector type
            A.3.2 Positioning and number of detectors
        A.4 Selection of hold-open device
            A.4.1 General
            A.4.2 Swing doors
            A.4.3 Sliding doors
            A.4.4 Roller shutter and lifting doors
            A.4.5 Automatic doors
        A.5 Manual release and manual control
            A.5.1 General
            A.5.2 Location of switch/push-button
        A.6 Interconnecting cables
        A.7 Guidance on competence and responsibilities
            for individual installations in individual
            buildings
            A.7.1 Planning
            A.7.2 Installation
Annex B (informative) - Recommendations for installation and
                        fixing of the hold-open system
Annex C (informative) - Recommendations for acceptance
                        inspection of the hold-open system
Annex D (informative) - Acceptance inspection report form
Annex E (informative) - Recommendations for usage and
                        maintenance of the hold-open system
        E.1 Usage of installations
            E.1.1 General
            E.1.2 Periodic inspection
        E.2 Routine site inspection report form
Annex F (informative) - Evaluation of conformity
        F.1 General
            F.1.1 Introduction
            F.1.2 Initial type test
            F.1.3 Characteristics
            F.1.4 Use of historical data
            F.1.5 Treatment of calculated values and design
            F.1.6 Sampling, testing and conformity criteria
        F.2 Factory production control (FPC)
            F.2.1 General
            F.2.2 FPC requirements for all manufacturers
        F.3 Further testing of sample systems
            F.3.1 Periodic testing
            F.3.2 Yearly testing
            F.3.3 Manufacturer-specific FPC system requirements
Annex G (informative) - Type test report and list of approved
                        components
        G.1 Test report
        G.2 List of approved components
Annex H (informative) - Example methodology for theoretical
                        analysis
        H.1 Introduction
        H.2 Points for analysis
            H.2.1 General
            H.2.2 List of characteristics
Bibliography

This European Standard specifies requirements, methods of test and performance criteria against which the compatibility of components and their performance can be assessed when used in combination to form an electrically controlled hold-open system. It also specifies requirements for the integrity of such hold-open systems when connected to fire detection and fire alarm systems or other systems, including the signal exchange and technical data for interfaces.This European Standard provides requirements for the application of electrically controlled hold-open systems used for fire/smoke doors in buildings, where such doors are required to be self-closing. It covers planning, design (see Annex A), installation (see Annex B), commissioning, use and maintenance (see Annex E) of hold-open systems, intended for the protection of life and/or the protection of property. This may also include hold-open systems, or components of the hold-open system, that are self-contained in a single enclosure.Electrically controlled hold-open systems manufactured, installed and serviced in accordance with this European Standard are recommended for use wherever there is a requirement for reliable hold-open and release of an individual self-closing fire/smoke door assembly in the case of fire.The use of hold-open systems for closures in conveyor systems conforming to EN 1366-7, which applies in conjunction with EN 1363-1, may require additional proof of suitability, which is not covered by this European Standard.This European Standard does not cover design, installation, commissioning, use and maintenance of building fire detection and fire alarm systems (covered by CEN/TS 54-14) but does cover the connection of hold-open systems conforming to this European Standard to building fire detection and fire alarm systems, under certain prescribed conditions.This European Standard does not cover the requirements of performance characteristics and operational environment conditions of part

Committee
CEN/TC 33
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
DIN EN 14637:2008-01 Identical
UNE-EN 14637:2008 Identical
NF EN 14637 : 2008 Identical
UNI EN 14637 : 2008 Identical
NBN EN 14637 : 2008 Identical
NS EN 14637 : 1ED 2007 Identical
SN EN 14637 : 2007 Identical
I.S. EN 14637:2007 Identical
BS EN 14637:2007 Identical
NEN EN 14637 : 2007 Identical
PN EN 14637 : 2007 Identical
DIN EN 14637 E : 2008 Identical

BS EN 16034:2014 Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics
I.S. EN 16034:2014 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS
UNI EN 16034 : 2014 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS
11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE
VDI 6010 Blatt 2:2011-05 Technical safety installations - Automation and control of fire protective services
S.R. CEN/TR 15894:2009 BUILDING HARDWARE - DOOR FITTINGS FOR USE BY CHILDREN, ELDERLY AND DISABLED PEOPLE IN DOMESTIC AND PUBLIC BUILDINGS - A GUIDE FOR SPECIFIERS
UNE-EN 16034:2015 Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics
DIN EN 16034:2014-12 PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS
EN 16034:2014 Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics
PD CEN/TR 15894:2009 Building hardware. Door fittings for use by children, elderly and disabled people in domestic and public buildings. A guide for specifiers
UNI CEN/TR 15894 : 2009 BUILDING HARDWARE - DOOR FITTINGS FOR USE BY CHILDREN, ELDERLY AND DISABLED PEOPLE IN DOMESTIC AND PUBLIC BUILDINGS - A GUIDE FOR SPECIFIERS
CEN/TR 15894:2009 Building hardware - Door fittings for use by children, elderly and disabled people in domestic and public buildings - A guide for specifiers

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
EN 1155:1997/A1:2002/AC:2006 BUILDING HARDWARE - ELECTRICALLY POWERED HOLD-OPEN DEVICES FOR SWING DOORS - REQUIREMENTS AND TEST METHODS
NFS 61 937 : 1990 AMD 1 2006 FIRE SAFETY - OPERATED SAFETY DEVICES
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
NFS 61 950 : 2004 FIRE DETECTION EQUIPMENT - LINEAR HEAT AND MULTIPOINT SMOKE DETECTORS AND INTERMEDIATE ELEMENTS
EN 1158:1997/A1:2002/AC:2006 BUILDING HARDWARE - DOOR COORDINATOR DEVICES - REQUIREMENTS AND TEST METHODS
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 61000-6-3:2007/A1:2011/AC:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-3: GENERIC STANDARDS - EMISSION STANDARD FOR RESIDENTIAL, COMMERCIAL AND LIGHT-INDUSTRIAL ENVIRONMENTS (IEC 61000-6-3:2006/A1:2010)
EN 12605:2000 Industrial, commercial and garage doors and gates - Mechanical aspects - Test methods
EN 1670:2007/AC:2008 BUILDING HARDWARE - CORROSION RESISTANCE - REQUIREMENTS AND TEST METHODS
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 60950-1:2006/A2:2013 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED)
EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
EN 12978:2003+A1:2009 Industrial, commercial and garage doors and gates - Safety devices for power operated doors and gates - Requirements and test methods
CEN/TS 54-14:2004 Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance
IEC 61000-6-3:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments
EN 1366-7:2004 Fire resistance tests for service installations - Part 7: Conveyor systems and their closures
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 61000-6-2:2005/corrigendum:2005 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60669-1:2017 Switches for household and similar fixed-electrical installations - Part 1: General requirements
EN 1154:1996/A1:2002/AC:2006 BUILDING HARDWARE - CONTROLLED DOOR CLOSING DEVICES - REQUIREMENTS AND TEST METHODS
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
ISO 9001:2015 Quality management systems — Requirements
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
NFS 61 961 : 2007 FIRE DETECTION EQUIPMENT - ACTUATING DETECTOR SYSTEMS
EN 54-13:2017 Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components
EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
EN 1191:2012 Windows and doors - Resistance to repeated opening and closing - Test method
EN 54-11:2001/A1:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.