• There are no items in your cart

EN 54-27:2015

Current
Current

The latest, up-to-date edition.

Fire detection and fire alarms systems - Part 27: Duct smoke detectors
Published date

03-11-2015

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, abbreviated terms and definitions
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
  performance (AVCP)
7 Classification
8 Marking, labelling and packaging
9 Data
Annex A (normative) - Aerosol tunnel arrangement
         for response measurements
Annex B (normative) - Test aerosol for response threshold
         value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Apparatus for dazzling test
Annex E (normative) - Fire test room and working volume
         arrangements for fire tests
Annex F (normative) - Smouldering (pyrolysis) wood fire
         (TF2D)
Annex G (normative) - Flaming plastics (polyurethane) fire
         (TF4D)
Annex H (normative) - Low temperature black smoke
         (decaline) liquid fire (TF8D)
Annex I (informative) - Information concerning the
         construction of the tunnel for fire tests
Annex J (informative) - Information concerning the
         construction of the measuring ionization chamber
Annex K (informative) - Information about DSD used as
         a stand-alone system
Annex L (informative) - Power supply
Annex M (informative) - Information concerning test
         procedures and requirements for the response to
         slowly developing fires
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Regulation
Bibliography

This European Standard specifies requirements, test methods and performance criteria for fire detectors which detect smoke in air ducts in buildings as a part of a fire detection and fire alarm system or as an actuator for a fire protection system.Duct smoke detectors with special characteristics and developed for specific risks are not covered by this document.NOTECertain types of detector contain radioactive materials. The national requirements for radiation protection differ from one member state to another and are not specified in this standard.

Committee
CEN/TC 72
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
DIN EN 54-27:2015-05 Identical
NF EN 54-27 : 2015 Identical
NBN EN 54-27 : 2015 Identical
NEN EN 54-27 : 2015 Identical
NS EN 54-27 : 2015 Identical
I.S. EN 54-27:2015 Identical
PN EN 54-27 : 2015 Identical
UNI EN 54-27 : 2015 Identical
UNE-EN 54-27:2019 Identical
SN EN 54-27:2015 Identical
BS EN 54-27:2015 Identical
DIN EN 54-27 E : 2015 Identical

11/30249544 DC : 0 BS EN 54-14 - FIRE DETECTION AND FIRE ALARM SYSTEMS - GUIDELINES FOR PLANNING, DESIGN, INSTALLATION, COMMISSIONING, USE AND MAINTENANCE
VDI 3819 Blatt 2:2013-07 Fire protection building services - Functions and correlations

IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV Information technology equipment - Safety - Part 1: General requirements
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-20:2006/AC:2008 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS
EN 60950-1:2006/A2:2013 INFORMATION TECHNOLOGY EQUIPMENT - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60950-1:2005/A2:2013, MODIFIED)
EN 54-7:2000/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 7: SMOKE DETECTORS - POINT DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-13:2017 Fire detection and fire alarm systems - Part 13: Compatibility and connectability assessment of system components
EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.