EN 60076-4:2002

Current

Current

The latest, up-to-date edition.

Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors

Published date

09-10-2002

FOREWORD
1 Scope
2 Normative references
3 General
4 Specified waveshapes
5 Test circuit
6 Calibration
7 Lightning impulse tests
   7.1 Waveshapes
   7.2 Impulses chopped on the tail
   7.3 Terminal connections and applicable methods of
        failure detection
   7.4 Test procedures
   7.5 Recording of tests
8 Switching impulse tests
   8.1 Special requirements
   8.2 Transformers
   8.3 Reactors
9 Interpretation of oscillograms or digital recordings
   9.1 Lightning impulse
   9.2 Switching impulse
10 Digital processing, including transfer function analysis
11 Impulse test reports
Annex A (informative) Principles of waveshape control
Annex B (informative) Typical oscillograms and digital
        recordings
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications

Gives guidance and explanatory comments on the existing procedures for lightning and switching impulse testing of power transformers to supplement the requirements of EN 60076-3. Also generally applicable to the testing of reactors (see EN 60289), modifications to power transformer procedures being indicated where required. Information is given on waveshapes, test circuits including test connections, earthing practices, failure detection methods, test procedures, measuring techniques and interpretation of results.

Committee
CLC/TC 14
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

UNE-EN 50541-1:2012 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
BS EN 60076-6:2008 Power transformers Reactors
EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3 150 kVA, with highest voltage for equipment not exceeding 36 kV - Part 1: General requirements
BS EN 50541-1:2011 Three phase dry-type distribution transformers 50 Hz, from 100 kVA to 3150 kVA, with highest voltage for equipment not exceeding 36 kV General requirements
I.S. EN 50299:2004 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72.5 KV TO 550 KV
CEI EN 50541-1 : 2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
I.S. EN 60310:2016 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK
I.S. EN 50541-1:2011 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 KVA TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS
PREN 50541-1 : DRAFT 2009 THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
I.S. EN 60076-6:2008 POWER TRANSFORMERS - PART 6: REACTORS
09/30211604 DC : 0 BS EN 50541-1 - THREE PHASE DRY-TYPE DISTRIBUTION TRANSFORMERS 50 HZ, FROM 100 TO 3150 KVA, WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR DRY TYPE TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV
BS EN 60310:2016 Railway applications. Traction transformers and inductors on board rolling stock
CEI EN 60076-6 : 2015 POWER TRANSFORMERS - PART 6: REACTORS
I.S. EN 50327:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 60076-6:2008 Power transformers - Part 6: Reactors
EN 60310:2016/AC:2018-03 RAILWAY APPLICATIONS - TRACTION TRANSFORMERS AND INDUCTORS ON BOARD ROLLING STOCK (IEC 60310:2016/COR1:2018)

IEC 60060-2:2010 High-voltage test techniques - Part 2: Measuring systems
HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
EN 60060-2:2011 High-voltage test techniques - Part 2: Measuring systems
EN 61083-1:2001 Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments
EN 60289:1994/A11:2002 REACTORS
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
IEC 61083-2:2013 Instruments and software used for measurement in high-voltage and high-current tests - Part 2: Requirements for software for tests with impulse voltages and currents
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60289:1988 Reactors
IEC 61083-1:2001 Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments
EN 61083-2:2013 Instruments and software used for measurement in high-voltage and high-current tests - Part 2: Requirements for software for tests with impulse voltages and currents

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.