GR 606 CORE : ISSUE 6

Current

Current

The latest, up-to-date edition.

LSSGR: COMMON CHANNEL SIGNALING, SECTION 6.5

Published date

01-12-2013

Preface
1 Overview
      1.1 Reasons for Reissue
      1.2 CCS Network Access
      1.3 Signaling System Number 7 Protocol
      1.4 Multiple Point Code Capability
2 Signaling Link Characteristic
      2.1 Description of Signaling Data Links
      2.2 Synchronization Requirements for DSOA Interfaces
              2.2.1 Composite Clock Redundancy Requirements
              2.2.2 Composite Clock Robustness Requirements
      2.3 SS7 Signal Units
      2.4 Error Detection and Recovery
      2.5 Signal Unit Error Monitoring
      2.6 Signaling Link Initial Alignment
      2.7 Processor Outage
      2.8 Signaling Link Busy
      2.9 Link Performance
      2.10 False Link Congestion Detection
3 Message Signal Unit Information Handling
      3.1 Routing Label Information
      3.2 Message Discrimination and Distribution
      3.3 Message Routing
              3.3.1 Back-up Routing Procedures
      3.4 Loadsharing
      3.5 Message Sequencing
4 Signaling Network Management
      4.1 Signaling Link Activation
      4.2 Signaling Link Changeover
      4.3 Signaling Link Changeback
      4.4 Forced Rerouting
      4.5 Controlled Rerouting
      4.6 MTP Restart
              4.6.1 Overview of the MTP Restart Procedures
              4.6.2 Requirements for a Restarting SPCS
              4.6.3 Requirements for an SPCS Adjacent to a
                        Restarting Node
              4.6.4 Receipt of an Unexpected TRW/TRA Message
              4.6.5 General Requirements
      4.7 Management Inhibiting
              4.7.1 Signaling Link Inhibiting
              4.7.2 Signaling Link Uninhibiting
      4.8 Message Priorities and Congestion Control
      4.9 Signaling Route Management
              4.9.1 Transfer-Prohibited
              4.9.2 Transfer-Cluster-Prohibited
              4.9.3 Transfer-Allowed
              4.9.4 Transfer-Cluster-Allowed
              4.9.5 Transfer-Restricted
              4.9.6 Transfer-Cluster-Restricted
              4.9.7 Signaling-Route-Set-Test Procedures
              4.9.8 Transfer Controlled
              4.9.9 Signaling-Route-Set-Congestion-Test
      4.10 Signaling Link Tests
      4.11 MTP User Flow Control
5 Noncircuit-Related Information Exchange - SCCP
      5.1 SCCP Protocol Class
      5.2 Connectionless Signaling Procedures
              5.2.1 SCCP Message Return
      5.3 SCCP Segmentation and Reassembly
              5.3.1 Segmenting
                        5.3.1.1 Segmentation Criteria
                        5.3.1.2 Segmentation Procedures
              5.3.2 Reassembling
                        5.3.2.1 Initiating a Reassembly Process
                        5.3.2.2 Reassembly Procedures
      5.4 SCCP Management
6 Additional Procedures for SPCS-to-SPCS/SCP TCAP Messages
      6.1 Scope and Applicability
      6.2 Definitions
      6.3 Overview
      6.4 The Analysis Processing Units
      6.5 Formatting and Coding Requirements
      6.6 Requirements for Feature Override
      6.7 Treatment Processing Summary
      6.8 Administrative Data
      6.9 Error Procedures
7 Circuit-Related Information Exchange
8 SPCS Capacity
9 Performance
      9.1 General Considerations
      9.2 Service (All Causes) Downtime Objectives
              9.2.1 SPCS Total System Downtime
              9.2.2 SPCS Link Downtime
      9.3 Hardware Downtime Requirements
              9.3.1 Predicted SPCS Total System Downtime
              9.3.2 Predicted SPCS Link Downtime
Appendix A: SS7 Message Formatting Guidelines
    A.1 Basic Principles
    A.2 Signal Unit Encoding
    A.3 Message Signal Unit Routing Label
    A.4 Signaling Network Management Message Formats
              A.4.1 Changeover Messages
              A.4.2 Emergency Changeover Messages
              A.4.3 Changeback Messages
              A.4.4 Management Inhibit Messages
              A.4.5 Transfer Prohibited/Restricted/Allowed
                        Messages
              A.4.6 Signaling-Route-Set-Test Messages
              A.4.7 Transfer Controlled Message
              A.4.8 Signaling-Route-Set-Congestion-Test-Message
              A.4.9 Traffic Restart Message
              A.4.10 Signaling Link Test Messages
              A.4.11 User Part Unavailable Message
    A.5 Circuit-Related Message Format
    A.6 Noncircuit-Related Message Formats
              A.6.1 SCCP Interfaces to SCCP-User Parts
              A.6.2 Unitdata and Extended Unitdata Messages
              A.6.3 Additional Information to Support Routing
                        of TCAP Messages
              A.6.4 SCCP Management
              A.6.5 Non-circuit Related Service Messages
              A.6.6 Extended Unitdata Service Messages
Appendix B: SPCS Internal Congestion Control
    B.1 Background
    B.2 Guidelines Based on Processing Priority
              B.2.1 Internal SPCS Processing Priority Classes
              B.2.2 Internal SPCS Congestion Thresholds
              B.2.3 Treatment During Internal SPCS Congestion
    B.3 Guidelines Based on Automatic Gapping
              B.3.1 Internal SPCS Congestion Thresholds
              B.3.2 Treatment During Internal SPCS Congestion
Appendix C: Technical Description of ISNI
    C.1 Introduction
    C.2 Motivation
              C.2.1 Definitions
    C.3 ISNI Capability
              C.3.1 Notification Function
              C.3.2 Routing Function
              C.3.3 SCCP ISNI Parameter
    C.4 Message Routing
              C.4.1 Message Routing With SCCP ISNI
    C.5 Summary
Appendix D: Test Considerations for GRP
    D.1 Introduction
    D.2 Test Configuration
    D.3 Treatment Analysis Tests
              D.3.1 Initial TCAP Message Tests
              D.3.2 Subsequent TCAP Message Tests
    D.4 ICN Identity Analysis Tests
              D.4.1 Initial TCAP Message Tests
              D.4.2 Subsequent TCAP Message Tests
    D.5 Routing Data Analysis Tests
              D.5.1 Routing Data Analysis for Treatment 2
              D.5.2 Routing Data Analysis for Treatment 3
    D.6 Override Tests
              D.6.1 Treatment Override Tests
              D.6.2 ICN Identity Override Tests
              D.6.3 Destination Point Code (DPC) Override Tests
    D.7 Administrative Data Tests
    D.8 Error Procedures Tests
Appendix E: Operations Requirements for Section 6.5
    E.1 Introduction
    E.2 Memory Administration Requirements
              E.2.1 General
              E.2.2 Memory Administration Requirements for
                        MTP Restart
              E.2.3 Memory Administration Requirements for
                        False Link Congestion Detection
              E.2.4 Memory Administration Requirements for a
                        Full Transmit Buffer
              E.2.5 Memory Administration Requirements for E-Links
              E.2.6 Memory Administration Requirements for
                        SCCP Segmentation
              E.2.7 Memory Administration Requirements for
                        SPCS-to-SPCS/SCP TCAP Messages
              E.2.8 Memory Administration Requirements to Support
                        the Multiple Point Code Capability
              E.2.9 Memory Administration Requirements for
                        Unrecognized SCCP Messages
              E.2.10 Memory Administration Requirements for
                        Connectionless Signaling Procedures
    E.3 Surveillance Requirements
              E.3.1 Event Notification Requirements
              E.3.2 Surveillance Measurement Requirements
    E.4 Traffic Measurement Requirements
              E.4.1 General
              E.4.2 Traffic Measurement Requirements for MTP
                        Restart
              E.4.3 Traffic Measurement Requirements for
                        False Link Congestion Detection
              E.4.4 Traffic Measurement Requirements for a
                        Full Transmit Buffer
              E.4.5 Traffic Measurement Requirements for E-Links
              E.4.6 Traffic Measurement Requirements for
                        SCCP Segmentation
              E.4.7 Traffic Measurement Requirements
                        SPCS-to-SPCS/SCP TCAP Messages
              E.4.8 Traffic Measurement Requirements to Support
                        the Multiple Point Code Capability
              E.4.9 Traffic Measurement Requirements for
                        Unrecognized SCCP Messages
              E.4.10 Traffic Measurement Requirements to
                        Support Connectionless Signaling Procedures
References
Glossary

Describes MTP Restart requirements to clearly state that Traffic Restart Allowed (TRA) messages are expected to be received from nodes that are available on directly accessible link sets.

DevelopmentNote
Included in FR CCS 18. (01/2001) Supersedes TR NWT 000606. (03/2004) Supersedes TA NWT 000606. (07/2004) Included in FR SS 01. (01/2012)
DocumentType
Standard
PublisherName
Telcordia Technologies
Status
Current
Supersedes

GR 3170 CORE : ISSUE 1 LEGACY SELECTIVE ROUTER (SR) GATEWAY GENERIC REQUIREMENTS
GR 866 CORE : ISSUE 1 REV 1 ISDN MESSAGE SERVICE GENERIC SWITCHING AND SIGNALLING REQUIREMENTS
GR 2936 CORE : ISSUE 3 LOCAL NUMBER PORTABILITY (LNP) CAPABILITY SPECIFICATION: SERVICE PROVIDER PORTABILITY
GR 606 ILR : ISSUE 2A LSSGR: COMMON CHANNEL SIGNALING, SECTION 6.5
GR 82 ILR : ISSUE 2A SIGNALING TRANSFER POINT (STP) GENERIC REQUIREMENTS ISSUES LIST REPORT
GR 505 CORE : ISSUE 2 CALL PROCESSING
GR 2878 CORE : ISSUE 4 GENERIC REQUIREMENTS FOR CCS NODES SUPPORTING ATM HIGH-SPEED SIGNALING LINKS (HSLS)
GR 394 CORE : ISSUE 8 LSSGR: SWITCHING SYSTEM GENERIC REQUIREMENTS FOR INTEREXCHANGE CARRIER INTERCONNECTION (ICI) USING THE INTEGRATED SERVICES DIGITAL NETWORK USER PART (ISDNUP)
GR 3162 CORE : ISSUE 4 LEGACY NETWORK GATEWAY GENERIC REQUIREMENTS
GR 1241 CORE : ISSUE 7 SUPPLEMENTAL SERVICE CONTROL POINT (SCP) GENERIC REQUIREMENTS
GR 2982 CORE : ISSUE 1 LOCAL NUMBER PORTABILITY (LNP) CAPABILITY SPECIFICATION: LOCATION PORTABILITY
GR 317 CORE : ISSUE 10 LSSGR: SWITCHING SYSTEM GENERIC REQUIREMENTS FOR CALL CONTROL USING THE INTEGRATED SERVICES DIGITAL NETWORK USER PART (ISDNUP)
GR 2946 CORE : ISSUE 3 CCSNIS SUPPORTING NETWORK INTERCONNECTION USING HIGH-SPEED SIGNALING LINKS (HSLS)
GR 1417 CORE : ISSUE 5 BROADBAND SWITCHING SYSTEM SS7 GENERIC REQUIREMENTS
GR 1299 CORE : ISSUE 10 AINGR: SWITCH - SERVICE CONTROL POINT (SCP)/ADJUNCT INTERFACE

GR 317 CORE : ISSUE 10 LSSGR: SWITCHING SYSTEM GENERIC REQUIREMENTS FOR CALL CONTROL USING THE INTEGRATED SERVICES DIGITAL NETWORK USER PART (ISDNUP)
GR 284 CORE : ISSUE 1 RELIABILITY AND QUALITY SWITCHING SYSTEMS GENERIC REQUIREMENTS (RQSSGR)
GR 82 CORE : ISSUE 15 SIGNALING TRANSFER POINT (STP) GENERIC REQUIREMENTS
GR 246 CORE : ISSUE 10 TELCORDIA TECHNOLOGIES SPECIFICATION OF SIGNALLING SYSTEM NUMBER 7
GR 378 CORE : ISSUE 4 GENERIC REQUIREMENTS FOR TIMING SIGNAL GENERATORS
TR TSY 000458 : ISSUE 1 DIGITAL SIGNAL ZERO "A" (DS-0A 64 KB/S) SYSTEMS INTERCONNECTION
GR 510 CORE : ISSUE 1 LSSGR: SYSTEM INTERFACES SECTION 10
GR 1245 CORE : ISSUE 3 CCS NODE GENERIC REQUIREMENTS TO SUPPORT ROUTING VERIFICATION TESTS
GR 394 CORE : ISSUE 8 LSSGR: SWITCHING SYSTEM GENERIC REQUIREMENTS FOR INTEREXCHANGE CARRIER INTERCONNECTION (ICI) USING THE INTEGRATED SERVICES DIGITAL NETWORK USER PART (ISDNUP)
FR 439 : ISSUE 2011 OPERATIONS TECHNOLOGY GENERIC REQUIREMENTS (OTGR)
GR 2857 CORE : ISSUE 3 RTPFR: GENERIC REQUIREMENTS FOR THE SIGNALING SYSTEM 7 (SS7) RELEASE TO PIVOT (RTP) PHASE I NETWORK CAPABILITY
TA TSY 000083 : ISSUE 2 GENERIC REQUIREMENTS FOR THE DDS NETWORK-OFFICE CHANNEL UNIT
GR 472 CORE : ISSUE 2 REV 2 OPERATIONS TECHNOLOGY GENERIC REQUIREMENTS (OTGR) SECTION 2.1: NETWORK ELEMENT CONFIGURATION MANAGEMENT
GR 833 CORE : ISSUE 7 TL1 SURVEILLANCE AND MAINTENANCE MESSAGES
GR 508 CORE : ISSUE 4 LSSGR: AUTOMATIC MESSAGE ACCOUNTING (AMA), SECTION 8
TR TSY 000821 : ISSUE 1 REV 3 OTGR SECTION 5.2: NETWORK MAINTENANCE: TRANSPORT SURVEILLANCE - ADDITIONAL TRANSPORT AND TRANSPORT-BASED SURVEILLANCE
GR 2878 CORE : ISSUE 4 GENERIC REQUIREMENTS FOR CCS NODES SUPPORTING ATM HIGH-SPEED SIGNALING LINKS (HSLS)
GR 512 CORE : ISSUE 2 LSSGR: RELIABILITY, SECTION 12
GR 1298 CORE : ISSUE 10 AINGR: SWITCHING SYSTEMS
GR 2932 CORE : ISSUE 1 DATABASE FUNCTIONALITIES
GR 478 CORE : ISSUE 4 MEASUREMENTS AND DATA GENERATION
GR 474 CORE : ISSUE 2 NETWORK MAINTENANCE: ALARM AND CONTROL FOR NETWORK ELEMENTS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.