Provides a summary of information on fire, tests and flammability relevant to building materials, products and construction, referring to appropriate Australian Standards.

This part of the Handbook deals generally with matters relating to fire and fire tests concerning building materials, products and construction.This document lists individual Standards and Codes published by Standards Australia, and identifies appropriate procedures and documents prepared by other Australian and overseas organizations. This document is a general guide directing users to Standards dealing in detail with specific areas of fire hazard assessment, fire protection and fire regulation.The Handbook does not provide mandatory requirements on fire matters but advises the user on the applicability of State, Territory and local government regulations.NOTES:1 The Building Code of Australia (BCA) calls up most of the fire test methods and related Standards needed to define requirements and levels of performance for buildings.2 The International Maritime Organization (IMO) has a number of fire test methods that are used for ship construction. Appendix A lists several of these IMO Resolutions.

Committee
FP-018
DocumentType
Handbook
ISBN
0 7262 8981 7
Pages
33
ProductNote
Reconfirmed 27/05/2016.This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
PublisherName
Standards Australia
Status
Current

First published as HB37.4-1994.Reconfirmed 2016. First published as SAA HB37.4-1994.

AS 3784.1-1990 Coatings for fire protection of building elements - Guide to selection and installation of sprayed mineral coatings
AS 1905.2-1989 Components for the protection of openings in fire-resistant walls (known as the SAA Fire Door Code) - Fire-resistant roller shutters
AS 2201.2-1992 Intruder alarm systems - Central stations
AS 2461-1981 Mineral wool thermal insulation - Loose fill
AS 2376.2-1981 Plastics building sheets - Glass fibre reinforced polyester (GRP)
AS/NZS 2243.8:2006 Safety in laboratories - Fume cupboards
AS 2376.1-1980 Plastics building sheets - Extruded PVC
AS 2243.10-1993 Safety in laboratories - Storage of chemicals
AS 2714-1993 The storage and handling of hazardous chemical materials - Class 5.2 substances (organic peroxides)
AS/NZS 2122.2:1999 Methods of test for determining combustion propagation characteristics of plastics - Determination of minimum oxygen concentration for flame propagation following top surface ignition of vertically orientated specimens
AS 4073-1993 Urea-formaldehyde foam thermal insulation - In situ set foam
AS 1366.1-1992 Rigid cellular plastics sheets for thermal insulation Rigid cellular polyurethane (RC/PUR) (Reconfirmed 2018)
AS 1530.5-1989 Methods for fire tests on building materials, components and structures Test for piloted ignitability
AS 2924-1987 Decorative thermosetting laminated sheets
AS/NZS 2243.10:2004 Safety in laboratories Storage of chemicals
AS 2243.8-1992 Safety in laboratories - Fume cupboards
AS 2419.1-1994 Fire hydrant installations - System design, installation and commissioning
AS 1530.3-1989 Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release
AS 2201.2-2004 Intruder alarm systems Monitoring centres
AS 1366.2-1992 Rigid cellular plastics sheets for thermal insulation Rigid cellular polyisocyanurate (RC/PIR) (Reconfirmed 2018)
AS 4072.1-2005 Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints (Reconfirmed 2016)
AS 1266-1986 Fire control plans for ships
AS 4072.1-1992 Components for the protection of openings in fire-resistant separating elements - Service penetrations and control joints
AS 1668.1-1991 The use of mechanical ventilation and air-conditioning in buildings - Fire and smoke control
AS 3959-1999 Construction of buildings in bushfire-prone areas
AS/NZS 1530.3:1999 Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release (Reconfirmed 2016)
AS 1366.3-1992 Rigid cellular plastics sheets for thermal insulation Rigid cellular polystyrene - Moulded (RC/PS - M) (Reconfirmed 2018)
AS 1635.19.1-1974 Methods of testing pressure sensitive adhesive tape - Flammability
AS 1720.4-2006 Timber structures Fire resistance for structural adequacy of timber members
AS 3860-1991 Fixed guideway people movers
AS 1530.4-1990 Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction
AS 1903 TO 1904-1976 Reflective foil laminate
AS 2462-1981 Cellulosic fibre thermal insulation
AS 1720.4-1990 Timber structures Fire-resistance of structural timber members
AS 1668.2-1991 The use of mechanical ventilation and air-conditioning in buildings Mechanical ventilation for acceptable indoor-air quality
AS 2463-1981 Sea grass bulk thermal insulation
AS 2122.1-1993 Combustion characteristics of plastics Determination of flame propagation - Surface ignition of vertically oriented specimens of cellular plastics
AS 1905.1-2005 Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
AS 3961-2005 The storage and handling of liquefied natural gas
AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
AS 1905.2-2005 Components for the protection of openings in fire-resistant walls Fire-resistant roller shutters (Reconfirmed 2016)
AS 1905.1-1990 Components for the protection of openings in fire-resistant walls - Fire-resistant doorsets
AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
AS 2419.1-2005 Fire hydrant installations System design, installation and commissioning
AS 1366.4-1989 Rigid cellular plastics sheets for thermal insulation Rigid cellular polystyrene - Extruded (RC/PS-E) (Reconfirmed 2018)
AS 1530.1-1994 Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016)
AS 3742-1990 Mineral wool thermal insulation - Batt and blanket
AS 3959-1991 Construction of buildings in bushfire-prone areas
AS 1530.2-1993 Methods for fire tests on building materials, components and structures Test for flammability of materials (Reconfirmed 2016)
AS 2122.2-1978 Combustion propagation characteristics of plastics - Determination of minimum oxygen concentration for flame propagation following top surface ignition of vertically oriented specimens
AS 3961-1991 Liquefied natural gas - Storage and handling

View more information
US$26.49
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.