• There are no items in your cart

I.S. EN 60601-2-30:2000

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE SAFETY, INCLUDING ESSENTIAL PERFORMANCE, OF AUTOMATIC CYCLING NON-INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT
Available format(s)

Hardcopy , PDF

Superseded date

09-29-2010

Language(s)

English

Published date

01-01-2000

Preview

FOREWORD
INTRODUCTION
SECTION ONE - GENERAL
1 Scope and object
2 Terminology and definitions
3 General requirements
4 General requirements for tests
5 Classification
6 Identification, marking and documents
SECTION TWO - ENVIRONMENTAL CONDITIONS
SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
14 Requirements related to classification
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS
20 Dielectric strength
SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
21 Mechanical strength
22 Moving parts
SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR
                EXCESSIVE RADIATION
36 ELECTROMAGNETIC COMPATIBILITY
SECTION SIX - PROTECTION AGAINST THE HAZARDS OF IGNITION
                OF FLAMMABLE ANAESTHETIC MIXTURES
SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES
                AND OTHER SAFETY HAZARDS
42 Excessive temperatures
44 Overflow, spillage, leakage, humidity, ingress of liquids,
   cleaning, sterilization and disinfection, and compatibility
45 Pressure vessels and parts subject to PRESSURE
49 Interruption of the power supply
SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION
                AGAINST HAZARDOUS OUTPUT
50 Accuracy of operating data
51 Protection against hazardous output
SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS;
               ENVIRONMENTAL TESTS
SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
56 Components and general assembly
57 MAINS PARTS, components and lay-out
Annex L (normative) References - Publications mentioned in
                       this standard
Annex AA (informative) General guidance and rationale
Annex BB (informative) Alarm diagrams
Figures

Defines requirements for the safety, including essential performance, of AUTOMATIC CYCLING NON-INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT as defined in 2.102, hereinafter referred to as EQUIPMENT.

DocumentType
Standard
Pages
56
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
IEC 60601-2-30:1999 Identical
SN EN 60601-2-30 : 2000 Identical
UNE-EN 60601-2-30:2001 Identical
DIN EN 60601-2-30 : 2000 Identical
EN 60601-2-30:2000 Identical
BS EN 60601-2-30:2000 Identical
NF EN 60601-2-30 : 2002 Identical

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-2:2017 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60601-1-4:1996+AMD1:1999 CSV Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems

View more information
US$64.68
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.